<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Artigo técnico &#8211; PI Brasil &#8211; Associação PROFIBUS / PROFINET / ASi</title>
	<atom:link href="https://www.profibus.org.br/noticia/category/artigo-tecnico/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.profibus.org.br</link>
	<description></description>
	<lastBuildDate>Wed, 14 Oct 2026 16:12:27 +0000</lastBuildDate>
	<language>pt-BR</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0.7</generator>

<image>
	<url>https://www.profibus.org.br/wp-content/uploads/2024/12/cropped-logo-quadrada-32x32.png</url>
	<title>Artigo técnico &#8211; PI Brasil &#8211; Associação PROFIBUS / PROFINET / ASi</title>
	<link>https://www.profibus.org.br</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Comissionamento técnico de redes Ethernet-APL</title>
		<link>https://www.profibus.org.br/noticia/comissionamento-tecnico-de-redes-ethernet-apl/</link>
					<comments>https://www.profibus.org.br/noticia/comissionamento-tecnico-de-redes-ethernet-apl/#respond</comments>
		
		<dc:creator><![CDATA[Marketing]]></dc:creator>
		<pubDate>Wed, 14 Oct 2026 10:51:55 +0000</pubDate>
				<category><![CDATA[Artigo técnico]]></category>
		<guid isPermaLink="false">https://www.profibus.org.br/?p=13297</guid>

					<description><![CDATA[Da verificação da instalação ao baseline de entrega César Cassiolato (*) Resumo Este artigo apresenta um procedimento de comissionamento por porta para redes Ethernet-APL, desde a conferência de engenharia até os testes de processo e a entrega à manutenção. A qualidade do aceite depende de evidências elétricas, de integridade do enlace, de comunicação e de [&#8230;]]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><strong>Da verificação da instalação ao baseline de entrega</strong></p>
<p style="text-align: right;"><em>César Cassiolato (<strong>*</strong>)</em></p>
<p><strong>Resumo</strong><br />
Este artigo apresenta um procedimento de comissionamento por porta para redes Ethernet-APL, desde a conferência de engenharia até os testes de processo e a entrega à manutenção. A qualidade do aceite depende de evidências elétricas, de integridade do enlace, de comunicação e de função; Link UP isolado não comprova a saúde da instalação. A etapa de protocolo usa PROFINET sobre Ethernet-APL como exemplo e deve ser adaptada se a aplicação empregar outro protocolo.</p>
<p>Os limites de aprovação devem ser definidos previamente pelo projeto, pelo perfil de porta, pelo equipamento e pela documentação de fabricante. As grandezas do PHY podem ter nomes, escalas e sentidos diferentes conforme o transceptor; tendências só são comparáveis quando contexto e método de coleta são equivalentes.</p>
<p><strong>1 Fundamentos e arquitetura</strong><br />
Ethernet-APL aplica a transmissão 10BASE T1L à instrumentação de processo, com dados e alimentação pelo mesmo par em portas apropriadas. A arquitetura usual combina um APL Power Switch, um trunk, APL Field Switches e spurs individuais até os instrumentos. A interface com a rede industrial pode usar outro meio Ethernet e exigir conversão por switch. Requisitos de área classificada, perfis de porta, cabo e comprimento devem seguir a engenharia aprovada.</p>
<p><img fetchpriority="high" decoding="async" class="aligncenter wp-image-13276 " src="https://www.profibus.org.br/wp-content/uploads/2026/10/figura_01-e1791974950403.png" alt="" width="795" height="98" srcset="https://www.profibus.org.br/wp-content/uploads/2026/10/figura_01-e1791974950403.png 1500w, https://www.profibus.org.br/wp-content/uploads/2026/10/figura_01-e1791974950403-300x37.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/10/figura_01-e1791974950403-1024x126.png 1024w, https://www.profibus.org.br/wp-content/uploads/2026/10/figura_01-e1791974950403-768x95.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/10/figura_01-e1791974950403-555x68.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/10/figura_01-e1791974950403-1110x137.png 1110w, https://www.profibus.org.br/wp-content/uploads/2026/10/figura_01-e1791974950403-600x74.png 600w, https://www.profibus.org.br/wp-content/uploads/2026/10/figura_01-e1791974950403-1200x148.png 1200w" sizes="(max-width: 795px) 100vw, 795px" /></p>
<p style="text-align: center;"><em><strong>Figura 1 —</strong> Topologia ilustrativa. Cada spur liga uma porta do Field Switch a um instrumento; não representa dimensões nem limites universais.</em></p>
<p>Ethernet-APL especifica a camada física. Descoberta DCP, NameOfStation, GSDML, Application Relations, RT, MRP e S2 são itens do exemplo PROFINET; aplicações EtherNet/IP, HART IP ou OPC UA requerem testes de suas próprias pilhas e funções. LLDP pode auxiliar a topologia quando implementado.</p>
<p><strong>2 Planejamento e critérios de aceite<br />
</strong>Antes da energização, revisar topologia, lista de tags e portas, perfil elétrico, comprimento e tipo do cabo, áreas classificadas, versões de firmware, arquivos de descrição, endereços e requisitos de processo. Definir responsáveis, janela de teste, instrumento e método, duração da observação e formato das evidências. Medições em circuitos de área classificada devem seguir o procedimento aprovado e a documentação de segurança do equipamento.</p>
<p><img decoding="async" class="aligncenter wp-image-13277 " src="https://www.profibus.org.br/wp-content/uploads/2026/10/figura_02-e1791974982219.png" alt="" width="794" height="97" srcset="https://www.profibus.org.br/wp-content/uploads/2026/10/figura_02-e1791974982219.png 1500w, https://www.profibus.org.br/wp-content/uploads/2026/10/figura_02-e1791974982219-300x37.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/10/figura_02-e1791974982219-1024x125.png 1024w, https://www.profibus.org.br/wp-content/uploads/2026/10/figura_02-e1791974982219-768x94.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/10/figura_02-e1791974982219-555x68.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/10/figura_02-e1791974982219-1110x135.png 1110w, https://www.profibus.org.br/wp-content/uploads/2026/10/figura_02-e1791974982219-600x73.png 600w, https://www.profibus.org.br/wp-content/uploads/2026/10/figura_02-e1791974982219-1200x146.png 1200w" sizes="(max-width: 794px) 100vw, 794px" /></p>
<p style="text-align: center;"><em><strong>Figura 2 —</strong> Ordem de verificação do físico à função e à entrega.</em></p>
<p><img decoding="async" class="aligncenter wp-image-13251" src="https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_01_criterios_aceite.jpeg" alt="" width="795" height="303" srcset="https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_01_criterios_aceite.jpeg 2400w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_01_criterios_aceite-300x114.jpeg 300w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_01_criterios_aceite-1024x390.jpeg 1024w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_01_criterios_aceite-768x293.jpeg 768w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_01_criterios_aceite-1536x586.jpeg 1536w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_01_criterios_aceite-2048x781.jpeg 2048w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_01_criterios_aceite-555x212.jpeg 555w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_01_criterios_aceite-1110x423.jpeg 1110w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_01_criterios_aceite-600x229.jpeg 600w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_01_criterios_aceite-1200x458.jpeg 1200w" sizes="(max-width: 795px) 100vw, 795px" /></p>
<p><strong>3 Inspeção e testes elétricos<br />
</strong>Conferir identificação e rota do cabo, separação de potência, raio de curvatura, conectores, torque, vedação, blindagem e equipotencialização conforme projeto. Fotografar terminações e pontos críticos. Com portas isoladas e método apropriado, verificar continuidade, curto e resistência do par; não aplicar ensaios incompatíveis a eletrônica conectada.</p>
<p>Para cabo homogêneo, uma estimativa inicial é Rloop ≈ 2ρL/A + Rconexões, em que ρ é a resistividade do condutor, L é o comprimento de ida e A é a seção. Equivalentemente, Rloop ≈ 2Rcondutor + Rconexões. Corrigir a expectativa para temperatura e dados reais do cabo. Em regime, a aproximação Vdispositivo ≈ Vfonte − I·Rloop ajuda a examinar a margem; não substitui o cálculo completo do fabricante para partida, limites de porta ou distribuição de potência.</p>
<p>Registrar tensão no instrumento sob carga e corrente informada ou medida na porta. Uma resistência abaixo do máximo ainda pode indicar mudança relevante se divergir do valor calculado ou do baseline de uma instalação equivalente. A compatibilidade de perfil de potência e segurança deve ser verificada antes do aceite.</p>
<p><strong>4 Enlace físico e diagnóstico<br />
</strong>Confirmar estabelecimento do link em cada porta e coletar indicadores do PHY após estabilização, mantendo registrados modelo, firmware, temperatura aproximada, carga, instante e intervalo. Evitar comparar números de PHY distintos como se tivessem escala padronizada.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-13252" src="https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_02_diagnostico_phy.jpeg" alt="" width="795" height="352" srcset="https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_02_diagnostico_phy.jpeg 2400w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_02_diagnostico_phy-300x133.jpeg 300w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_02_diagnostico_phy-1024x453.jpeg 1024w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_02_diagnostico_phy-768x340.jpeg 768w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_02_diagnostico_phy-1536x679.jpeg 1536w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_02_diagnostico_phy-2048x905.jpeg 2048w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_02_diagnostico_phy-555x245.jpeg 555w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_02_diagnostico_phy-1110x491.jpeg 1110w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_02_diagnostico_phy-600x265.jpeg 600w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_02_diagnostico_phy-1200x531.jpeg 1200w" sizes="(max-width: 795px) 100vw, 795px" /></p>
<p>O contador deve ser registrado no início e no fim de uma janela definida, junto com duração e tráfego; uma leitura absoluta isolada pode refletir eventos anteriores. Use TDR apenas com ferramenta e porta compatíveis, conforme instruções do fabricante. Reflexões e distância estimada exigem correlação com o comprimento físico e a velocidade de propagação do cabo; uma curva saudável guardada na entrega é uma referência útil.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-13278 " src="https://www.profibus.org.br/wp-content/uploads/2026/10/figura_03-e1791975013203.png" alt="" width="796" height="104" srcset="https://www.profibus.org.br/wp-content/uploads/2026/10/figura_03-e1791975013203.png 1500w, https://www.profibus.org.br/wp-content/uploads/2026/10/figura_03-e1791975013203-300x39.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/10/figura_03-e1791975013203-1024x133.png 1024w, https://www.profibus.org.br/wp-content/uploads/2026/10/figura_03-e1791975013203-768x100.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/10/figura_03-e1791975013203-555x72.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/10/figura_03-e1791975013203-1110x144.png 1110w, https://www.profibus.org.br/wp-content/uploads/2026/10/figura_03-e1791975013203-600x78.png 600w, https://www.profibus.org.br/wp-content/uploads/2026/10/figura_03-e1791975013203-1200x156.png 1200w" sizes="(max-width: 796px) 100vw, 796px" /></p>
<p style="text-align: center;"><em><strong>Figura 3 —</strong> Investigação progressiva de uma porta com falha ou perda de margem.</em></p>
<p><strong>5 Descoberta e configuração de protocolo<br />
</strong>No exemplo PROFINET, comparar topologia planejada com vizinhos LLDP quando disponíveis; executar identificação DCP, conferir e atribuir NameOfStation e IP sem duplicidade; importar o GSDML compatível; estabelecer AR e validar IO Data, tempo de atualização, watchdog, alarmes e diagnóstico suportado. Registrar versões e capturas. Em MRP ou S2, realizar ensaio de redundância aprovado, observando tempo de recuperação e efeito na função. NE 107 descreve categorias de status quando mapeadas pelo dispositivo e pela aplicação.</p>
<p>Se o protocolo for outro, substituir estes passos pela descoberta, identidade, configuração, troca de dados, diagnósticos e redundância pertinentes à respectiva pilha. OPC UA e HART IP só devem entrar no teste quando estiverem de fato implementados no projeto.</p>
<p><strong>6 Testes funcionais e documentação<br />
</strong>Comparar variável de processo no instrumento e no DCS, validar unidade, escala, qualidade e atualização; simular alarmes e diagnósticos em condições permitidas; executar intertravamentos apenas segundo procedimento aprovado. Registrar estímulo, resposta esperada, resposta observada, horário e responsável. Uma função crítica não deve ser aprovada apenas com o link estável.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-13253" src="https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_03_testes_funcionais.jpeg" alt="" width="796" height="254" srcset="https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_03_testes_funcionais.jpeg 2400w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_03_testes_funcionais-300x96.jpeg 300w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_03_testes_funcionais-1024x327.jpeg 1024w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_03_testes_funcionais-768x245.jpeg 768w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_03_testes_funcionais-1536x490.jpeg 1536w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_03_testes_funcionais-2048x654.jpeg 2048w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_03_testes_funcionais-555x177.jpeg 555w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_03_testes_funcionais-1110x354.jpeg 1110w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_03_testes_funcionais-600x192.jpeg 600w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_03_testes_funcionais-1200x383.jpeg 1200w" sizes="(max-width: 796px) 100vw, 796px" /></p>
<p>O pacote as built deve conter topologia, associação tag/porta, identificação dos ativos, versões, parâmetros de comunicação, medições elétricas, capturas PHY, contadores, curvas TDR quando aplicáveis, testes de processo, desvios e sua disposição. Treinar manutenção para localizar uma porta, consultar diagnósticos e comparar os valores atuais ao baseline.</p>
<p><strong>7 Estudo de caso ilustrativo<br />
</strong>Os números abaixo são fictícios e servem apenas para demonstrar o método. Dois registros da mesma porta e do mesmo modelo de PHY são comparados sob carga e condições semelhantes; não representam limiares universais.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-13254 " src="https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_04_estudo_caso-e1791975039872.jpeg" alt="" width="794" height="239" srcset="https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_04_estudo_caso-e1791975039872.jpeg 2400w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_04_estudo_caso-e1791975039872-300x91.jpeg 300w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_04_estudo_caso-e1791975039872-1024x309.jpeg 1024w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_04_estudo_caso-e1791975039872-768x232.jpeg 768w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_04_estudo_caso-e1791975039872-1536x463.jpeg 1536w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_04_estudo_caso-e1791975039872-2048x618.jpeg 2048w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_04_estudo_caso-e1791975039872-555x167.jpeg 555w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_04_estudo_caso-e1791975039872-1110x335.jpeg 1110w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_04_estudo_caso-e1791975039872-600x181.jpeg 600w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_04_estudo_caso-e1791975039872-1200x362.jpeg 1200w" sizes="(max-width: 794px) 100vw, 794px" /></p>
<p>A queda do SQI e o crescimento do contador motivam investigação, mas não identificam sozinhos a causa. A nova reflexão localiza uma região provável; a inspeção confirma a conexão defeituosa. Após o reparo, repetir as medições e o teste funcional. Guardar o registro antigo e a nova condição aprovada, com data e justificativa.</p>
<p><strong>8 Encerramento e aceite<br />
</strong>Encerrar quando as portas estiverem identificadas, as medições e testes forem rastreáveis, a comunicação e a função forem estáveis pelo intervalo acordado, as não conformidades críticas tiverem sido resolvidas e operação e manutenção tiverem recebido o as built e os baselines. Pendências não críticas exigem responsável, prazo e aceitação formal.</p>
<p><strong>Anexo A Folha de comissionamento por porta<br />
</strong>Preencher uma folha para cada porta e anexar medições, capturas e fotografias indicadas.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-13255 " src="https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_05_folha_por_porta-e1791975064662.jpeg" alt="" width="794" height="545" srcset="https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_05_folha_por_porta-e1791975064662.jpeg 2400w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_05_folha_por_porta-e1791975064662-300x206.jpeg 300w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_05_folha_por_porta-e1791975064662-1024x703.jpeg 1024w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_05_folha_por_porta-e1791975064662-768x527.jpeg 768w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_05_folha_por_porta-e1791975064662-1536x1055.jpeg 1536w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_05_folha_por_porta-e1791975064662-2048x1406.jpeg 2048w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_05_folha_por_porta-e1791975064662-555x381.jpeg 555w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_05_folha_por_porta-e1791975064662-1110x762.jpeg 1110w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_05_folha_por_porta-e1791975064662-600x413.jpeg 600w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_05_folha_por_porta-e1791975064662-1200x824.jpeg 1200w" sizes="(max-width: 794px) 100vw, 794px" /></p>
<p><strong><span lang="EN-US" style="font-size: 12.0pt; line-height: 115%; font-family: 'Arial',sans-serif;"><br />
Anexo B Checklist de aceitação</span></strong></p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-13256 " src="https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_06_checklist_aceitacao-e1791975098221.jpeg" alt="" width="794" height="512" srcset="https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_06_checklist_aceitacao-e1791975098221.jpeg 2400w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_06_checklist_aceitacao-e1791975098221-300x194.jpeg 300w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_06_checklist_aceitacao-e1791975098221-1024x660.jpeg 1024w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_06_checklist_aceitacao-e1791975098221-768x495.jpeg 768w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_06_checklist_aceitacao-e1791975098221-1536x991.jpeg 1536w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_06_checklist_aceitacao-e1791975098221-2048x1321.jpeg 2048w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_06_checklist_aceitacao-e1791975098221-555x358.jpeg 555w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_06_checklist_aceitacao-e1791975098221-1110x716.jpeg 1110w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_06_checklist_aceitacao-e1791975098221-600x387.jpeg 600w, https://www.profibus.org.br/wp-content/uploads/2026/10/tabela_06_checklist_aceitacao-e1791975098221-1200x774.jpeg 1200w" sizes="(max-width: 794px) 100vw, 794px" /></p>
<p>&nbsp;</p>
<p>&#8212;</p>
<p><em><strong>Referências:<br />
</strong></em>[1] FieldComm Group, ODVA, OPC Foundation e PI. Ethernet-APL Engineering Guideline, AG10190, versão 1.0, 2021. https://www.fieldcommgroup.org/sites/default/files/imce_files/technology/documents/Ethernet_APL_Engineering_Guideline_v1.0.pdf<br />
[2] FieldComm Group. Ethernet-APL Specifications, página de especificações e documentos técnicos. https://www.fieldcommgroup.org/technologies/ethernet-apl/apl-specifications<br />
[3] Ethernet-APL Project. Ethernet-APL, descrição de arquitetura, alimentação e camada física. https://www.ethernet-apl.org/about/<br />
[4] PROFIBUS &amp; PROFINET International. PROFINET over APL, descrição de integração e mídia. <a href="https://www.profibus.com/technologies/profinet/connectivity-technologies/profinet-over-apl">https://www.profibus.com/technologies/profinet/connectivity-technologies/profinet-over-apl</a><br />
[5] Artigos Técnicos César Cassiolato</p>
<p>&nbsp;</p>
<p><em>(<strong>*</strong>) <strong>César Cassiolato</strong>, CEO da <a href="https://www.vivaceinstruments.com.br/pt" target="_blank" rel="noopener">Vivace Process Instruments LTDA</a>.</em></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.profibus.org.br/noticia/comissionamento-tecnico-de-redes-ethernet-apl/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">13297</post-id>	</item>
		<item>
		<title>Dimensionamento de carga e performance em redes Ethernet-APL</title>
		<link>https://www.profibus.org.br/noticia/dimensionamento-de-carga-e-performance-em-redes-ethernet-apl/</link>
					<comments>https://www.profibus.org.br/noticia/dimensionamento-de-carga-e-performance-em-redes-ethernet-apl/#respond</comments>
		
		<dc:creator><![CDATA[Marketing]]></dc:creator>
		<pubDate>Wed, 09 Sep 2026 03:33:46 +0000</pubDate>
				<category><![CDATA[Artigo técnico]]></category>
		<guid isPermaLink="false">https://www.profibus.org.br/?p=13216</guid>

					<description><![CDATA[Cálculo de Banda · Ciclo RT · Número de dispositivos · Tráfego acíclico · Margens · Expansão César Cassiolato (*) Resumo A interface 10BASE-T1L oferece 10 Mbit/s full-duplex por enlace. Este artigo mostra que o dimensionamento de uma rede Ethernet-APL não deve se limitar à taxa nominal: é necessário considerar bytes cíclicos, overhead, tempo de [&#8230;]]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><strong>Cálculo de Banda · Ciclo RT · Número de dispositivos · Tráfego acíclico · Margens · Expansão</strong></p>
<p style="text-align: right;"><em>César Cassiolato (<strong>*</strong>)</em></p>
<p><strong>Resumo</strong><br />
A interface 10BASE-T1L oferece 10 Mbit/s full-duplex por enlace. Este artigo mostra que o dimensionamento de uma rede Ethernet-APL não deve se limitar à taxa nominal: é necessário considerar bytes cíclicos, overhead, tempo de ciclo, tráfego acíclico, diagnósticos, engenharia, margens e expansão.</p>
<p>Vamos ver exemplo com vários transmissores e o artigo mostra a metodologia, acrescentando fórmulas, análise de sensibilidade, cenários de 8/16/32 ms, tabelas de engenharia, orçamento de banda, critérios para uplinks, QoS, jitter, redundância e um formulário de cálculo para uso em projeto.</p>
<p><strong>1. Capacidade do 10BASE-T1L<br />
</strong>A taxa nominal é 10 Mbit/s full-duplex, isto é, 10 Mbit/s em cada direção simultaneamente. A 10 Mbit/s, um intervalo de 16 ms corresponde teoricamente a 160.000 bits, ou 20.000 bytes por direção. Esse valor é capacidade bruta; não representa payload útil disponível para a aplicação.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-13180 " src="https://www.profibus.org.br/wp-content/uploads/2026/09/tabela1_capacidade_teorica-e1788923219799.jpg" alt="" width="808" height="219" srcset="https://www.profibus.org.br/wp-content/uploads/2026/09/tabela1_capacidade_teorica-e1788923219799.jpg 1517w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela1_capacidade_teorica-e1788923219799-300x81.jpg 300w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela1_capacidade_teorica-e1788923219799-1024x277.jpg 1024w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela1_capacidade_teorica-e1788923219799-768x208.jpg 768w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela1_capacidade_teorica-e1788923219799-555x150.jpg 555w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela1_capacidade_teorica-e1788923219799-1110x300.jpg 1110w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela1_capacidade_teorica-e1788923219799-600x162.jpg 600w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela1_capacidade_teorica-e1788923219799-1200x324.jpg 1200w" sizes="(max-width: 808px) 100vw, 808px" /></p>
<p>Frames Ethernet e PROFINET carregam preâmbulo, endereços, identificadores, status, FCS e, conforme a configuração, VLAN e outros campos. Por isso, o cálculo de engenharia deve usar o tamanho efetivamente transmitido e reservar margem.</p>
<p><strong>2. Método de dimensionamento<br />
</strong></p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-13217" src="https://www.profibus.org.br/wp-content/uploads/2026/09/Dimensionamento-e1788923423408.png" alt="" width="538" height="430" srcset="https://www.profibus.org.br/wp-content/uploads/2026/09/Dimensionamento-e1788923423408.png 1012w, https://www.profibus.org.br/wp-content/uploads/2026/09/Dimensionamento-e1788923423408-300x240.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/09/Dimensionamento-e1788923423408-768x615.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/09/Dimensionamento-e1788923423408-555x444.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/09/Dimensionamento-e1788923423408-600x480.png 600w" sizes="(max-width: 538px) 100vw, 538px" /></p>
<p style="text-align: center;"><em>Figura 1 – Cinco etapas para dimensionar a carga.</em></p>
<p><strong>2.1 Definir o ciclo RT</strong><br />
O ciclo deve ser determinado pela dinâmica do processo e pela estratégia de controle. Reduzir o ciclo de 16 ms para 8 ms duplica a taxa necessária para transmitir o mesmo volume por unidade de tempo; aumentar para 32 ms reduz pela metade.</p>
<p><strong>2.2 Levantar os bytes por dispositivo<br />
</strong>Para cada dispositivo, levantar Input, Output, status e slots adicionais que participem ciclicamente. Valores típicos como exemplo, estão na ordem de 50 a 300 bytes em um total de equipamentos, considerando a transmissores, mas em um projeto deve usar os tamanhos reais dos módulos configurados.</p>
<p><strong>2.3 Incluir overhead<br />
</strong>Em geral temos uma aproximação 40–70 bytes de overhead por frame, dependendo de VLAN e cabeçalhos. Esse número deve ser substituído pelo valor real quando a arquitetura estiver definida.</p>
<p><strong>2.4 Fórmula básica<br />
</strong>Para uma aproximação inicial: Banda cíclica [bit/s] ≈ (Σ bytes transmitidos por ciclo × 8) / T_ciclo. Quando Input e Output forem enviados em frames distintos, o overhead deve ser contabilizado em cada frame correspondente, e não apenas uma vez por dispositivo.</p>
<p><strong>2.5 Reservar tráfego não cíclico e margem<br />
</strong>Além do IO cíclico, devem ser considerados serviços PROFINET acíclicos, LLDP, DCP, diagnósticos, engenharia e, quando presentes, OPC UA e HART-IP. Downloads, asset management e consultas intensivas podem criar picos.</p>
<p><strong>3. Estrutura do Ciclo RT</strong></p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-13218" src="https://www.profibus.org.br/wp-content/uploads/2026/09/RT.png" alt="" width="701" height="338" srcset="https://www.profibus.org.br/wp-content/uploads/2026/09/RT.png 1315w, https://www.profibus.org.br/wp-content/uploads/2026/09/RT-300x145.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/09/RT-1024x494.png 1024w, https://www.profibus.org.br/wp-content/uploads/2026/09/RT-768x371.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/09/RT-555x268.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/09/RT-1110x536.png 1110w, https://www.profibus.org.br/wp-content/uploads/2026/09/RT-600x290.png 600w, https://www.profibus.org.br/wp-content/uploads/2026/09/RT-1200x579.png 1200w" sizes="(max-width: 701px) 100vw, 701px" /></p>
<p style="text-align: center;"><em>Figura 2 – Representação conceitual de um orçamento temporal de 16 ms.</em></p>
<p>A figura é didática: não implica que todo tráfego seja rigidamente particionado nessas janelas. Ela representa o orçamento que o projeto precisa acomodar: IO, processamento/jitter, serviços concorrentes e margem.</p>
<p><strong>4. Exemplo numérico<br />
</strong>Vamos considerar 30 transmissores, ciclo de 16 ms, 120 bytes de Input e 40 bytes de Output, totalizando 160 bytes de payload por dispositivo, e adota aproximadamente 60 bytes de overhead.<strong><img loading="lazy" decoding="async" class="aligncenter wp-image-13181 " src="https://www.profibus.org.br/wp-content/uploads/2026/09/tabela2_exemplo_numerico-e1788923313165.jpg" alt="" width="728" height="352" srcset="https://www.profibus.org.br/wp-content/uploads/2026/09/tabela2_exemplo_numerico-e1788923313165.jpg 1517w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela2_exemplo_numerico-e1788923313165-300x145.jpg 300w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela2_exemplo_numerico-e1788923313165-1024x495.jpg 1024w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela2_exemplo_numerico-e1788923313165-768x371.jpg 768w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela2_exemplo_numerico-e1788923313165-555x268.jpg 555w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela2_exemplo_numerico-e1788923313165-1110x536.jpg 1110w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela2_exemplo_numerico-e1788923313165-600x290.jpg 600w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela2_exemplo_numerico-e1788923313165-1200x580.jpg 1200w" sizes="(max-width: 728px) 100vw, 728px" /></strong></p>
<p>Esse cálculo é um exemplo. Para engenharia detalhada, deve-se verificar quantos frames são efetivamente transmitidos por ciclo em cada direção e contabilizar o overhead de cada um. Como o enlace é full-duplex, também é recomendável calcular separadamente a ocupação em cada direção quando Input e Output forem assimétricos.</p>
<p><strong>5. Sensibilidade ao ciclo e número de dispositivos<br />
</strong></p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-13219" src="https://www.profibus.org.br/wp-content/uploads/2026/09/Ciclo-RT.png" alt="" width="628" height="441" srcset="https://www.profibus.org.br/wp-content/uploads/2026/09/Ciclo-RT.png 1251w, https://www.profibus.org.br/wp-content/uploads/2026/09/Ciclo-RT-300x211.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/09/Ciclo-RT-1024x720.png 1024w, https://www.profibus.org.br/wp-content/uploads/2026/09/Ciclo-RT-768x540.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/09/Ciclo-RT-555x390.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/09/Ciclo-RT-1110x781.png 1110w, https://www.profibus.org.br/wp-content/uploads/2026/09/Ciclo-RT-600x422.png 600w, https://www.profibus.org.br/wp-content/uploads/2026/09/Ciclo-RT-1200x844.png 1200w" sizes="(max-width: 628px) 100vw, 628px" /></p>
<p style="text-align: center;"><em>Figura 3 – Ocupação estimada para 200 bytes por dispositivo/ciclo em 8, 16 e 32 ms.</em></p>
<p>O gráfico evidencia a relação inversa entre tempo de ciclo e banda. Com a mesma quantidade de dados, 8 ms exige aproximadamente o dobro da taxa de 16 ms, enquanto 32 ms exige metade. Portanto, definir ciclos muito curtos sem necessidade de processo consome margem que poderia ser usada para expansão e tráfego concorrente.</p>
<p><strong>6. Sensibilidade ao tamanho de dados<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-13220" src="https://www.profibus.org.br/wp-content/uploads/2026/09/Dados.png" alt="" width="614" height="419" srcset="https://www.profibus.org.br/wp-content/uploads/2026/09/Dados.png 1235w, https://www.profibus.org.br/wp-content/uploads/2026/09/Dados-300x205.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/09/Dados-1024x698.png 1024w, https://www.profibus.org.br/wp-content/uploads/2026/09/Dados-768x524.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/09/Dados-555x378.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/09/Dados-1110x757.png 1110w, https://www.profibus.org.br/wp-content/uploads/2026/09/Dados-600x409.png 600w, https://www.profibus.org.br/wp-content/uploads/2026/09/Dados-1200x818.png 1200w" sizes="(max-width: 614px) 100vw, 614px" /></strong></p>
<p style="text-align: center;"><em>Figura 4 – Efeito do volume de dados no ciclo de 16 ms.</em></p>
<p>Dispositivos com mais módulos, status ou diagnósticos cíclicos aumentam a carga. A lista de IO deve ser congelada ou revisada antes do cálculo final; alterações de configuração podem modificar significativamente a ocupação.</p>
<p><strong>7. Orçamento de banda<br />
</strong></p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-13221" src="https://www.profibus.org.br/wp-content/uploads/2026/09/Orcamento-de-banda.png" alt="" width="416" height="373" srcset="https://www.profibus.org.br/wp-content/uploads/2026/09/Orcamento-de-banda.png 701w, https://www.profibus.org.br/wp-content/uploads/2026/09/Orcamento-de-banda-300x269.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/09/Orcamento-de-banda-555x497.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/09/Orcamento-de-banda-600x538.png 600w" sizes="(max-width: 416px) 100vw, 416px" /></p>
<p style="text-align: center;"><em>Figura 5 – Exemplo conceitual de distribuição da capacidade.</em></p>
<p>A reserva não é desperdício: ela absorve variações de carga, engenharia, diagnósticos, crescimento e condições transitórias. Uma recomendação é trabalhar normalmente com ocupação cíclica + acíclica na faixa de até 50–70% e alerta que acima de 85% a rede se torna mais sensível a picos e jitter. Esses percentuais devem ser tratados como regras práticas do artigo e validados contra a arquitetura real.</p>
<p><strong>8. Uplink e Agregação<br />
</strong>O spur APL pode não ser o gargalo. O uplink do Field Switch agrega múltiplas portas e pode carregar simultaneamente IO, diagnósticos, engenharia e tráfego de gestão. Por isso, deve ser dimensionado separadamente, considerando velocidade do uplink, quantidade de Field Switches agregados, VLANs, redundância e cenários de pico.</p>
<p><strong><img loading="lazy" decoding="async" class="aligncenter wp-image-13182 size-full" src="https://www.profibus.org.br/wp-content/uploads/2026/09/tabela3_uplink_agregacao-e1788924369851.jpg" alt="" width="2087" height="584" srcset="https://www.profibus.org.br/wp-content/uploads/2026/09/tabela3_uplink_agregacao-e1788924369851.jpg 2087w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela3_uplink_agregacao-e1788924369851-300x84.jpg 300w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela3_uplink_agregacao-e1788924369851-1024x287.jpg 1024w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela3_uplink_agregacao-e1788924369851-768x215.jpg 768w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela3_uplink_agregacao-e1788924369851-1536x430.jpg 1536w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela3_uplink_agregacao-e1788924369851-2048x573.jpg 2048w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela3_uplink_agregacao-e1788924369851-555x155.jpg 555w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela3_uplink_agregacao-e1788924369851-1110x311.jpg 1110w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela3_uplink_agregacao-e1788924369851-600x168.jpg 600w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela3_uplink_agregacao-e1788924369851-1200x336.jpg 1200w" sizes="(max-width: 2087px) 100vw, 2087px" /></strong></p>
<p><strong>9. QoS, Jitter e número de Hops<br />
</strong>A largura de banda média não é suficiente para caracterizar determinismo. Jitter de switches, filas, store-and-forward/cut-through, número de hops, prioridade VLAN PCP e rajadas concorrentes podem alterar a latência e a regularidade do RT.</p>
<ul>
<li>Priorizar frames RT nas filas apropriadas.</li>
<li>Evitar storms e broadcasts desnecessários.</li>
<li>Verificar comportamento de filas sob tráfego acíclico intenso.</li>
<li>Considerar o número de hops entre controlador e dispositivo.</li>
<li>Planejar downloads de firmware e operações intensivas de engenharia.</li>
</ul>
<p><strong>10. Cenários de projeto<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-13183 size-full" src="https://www.profibus.org.br/wp-content/uploads/2026/09/tabela4_cenarios_projeto-e1788924464856.jpg" alt="" width="2249" height="573" srcset="https://www.profibus.org.br/wp-content/uploads/2026/09/tabela4_cenarios_projeto-e1788924464856.jpg 2249w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela4_cenarios_projeto-e1788924464856-300x76.jpg 300w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela4_cenarios_projeto-e1788924464856-1024x261.jpg 1024w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela4_cenarios_projeto-e1788924464856-768x196.jpg 768w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela4_cenarios_projeto-e1788924464856-1536x391.jpg 1536w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela4_cenarios_projeto-e1788924464856-2048x522.jpg 2048w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela4_cenarios_projeto-e1788924464856-555x141.jpg 555w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela4_cenarios_projeto-e1788924464856-1110x283.jpg 1110w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela4_cenarios_projeto-e1788924464856-600x153.jpg 600w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela4_cenarios_projeto-e1788924464856-1200x306.jpg 1200w" sizes="(max-width: 2249px) 100vw, 2249px" /></strong></p>
<p><strong>11. Planilha de cálculo por dispositivo<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-13184 size-full" src="https://www.profibus.org.br/wp-content/uploads/2026/09/tabela5_planilha_calculo-e1788924549371.jpg" alt="" width="2168" height="463" srcset="https://www.profibus.org.br/wp-content/uploads/2026/09/tabela5_planilha_calculo-e1788924549371.jpg 2168w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela5_planilha_calculo-e1788924549371-300x64.jpg 300w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela5_planilha_calculo-e1788924549371-1024x219.jpg 1024w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela5_planilha_calculo-e1788924549371-768x164.jpg 768w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela5_planilha_calculo-e1788924549371-1536x328.jpg 1536w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela5_planilha_calculo-e1788924549371-2048x437.jpg 2048w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela5_planilha_calculo-e1788924549371-555x119.jpg 555w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela5_planilha_calculo-e1788924549371-1110x237.jpg 1110w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela5_planilha_calculo-e1788924549371-600x128.jpg 600w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela5_planilha_calculo-e1788924549371-1200x256.jpg 1200w" sizes="(max-width: 2168px) 100vw, 2168px" /></strong></p>
<p>Para maior precisão, calcular cada direção separadamente. Banda_In ≈ Σ[(Input + overhead correspondente) × 8]/T; Banda_Out ≈ Σ[(Output + overhead correspondente) × 8]/T. A ocupação percentual é a banda calculada dividida por 10 Mbit/s em cada direção.</p>
<p><strong>12. Checklist de dimensionamento<br />
<img loading="lazy" decoding="async" class="aligncenter wp-image-13185 " src="https://www.profibus.org.br/wp-content/uploads/2026/09/tabela6_checklist-e1788924653468.jpg" alt="" width="816" height="368" srcset="https://www.profibus.org.br/wp-content/uploads/2026/09/tabela6_checklist-e1788924653468.jpg 2005w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela6_checklist-e1788924653468-300x136.jpg 300w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela6_checklist-e1788924653468-1024x463.jpg 1024w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela6_checklist-e1788924653468-768x347.jpg 768w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela6_checklist-e1788924653468-1536x694.jpg 1536w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela6_checklist-e1788924653468-555x251.jpg 555w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela6_checklist-e1788924653468-1110x502.jpg 1110w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela6_checklist-e1788924653468-600x271.jpg 600w, https://www.profibus.org.br/wp-content/uploads/2026/09/tabela6_checklist-e1788924653468-1200x542.jpg 1200w" sizes="(max-width: 816px) 100vw, 816px" /><br />
</strong><strong>13. Recomendações para validação em comissionamento<br />
</strong>O cálculo de projeto deve ser confrontado com medições da rede real. Durante o comissionamento, registrar carga média e de pico, contadores de erro, latência/jitter quando disponíveis, comportamento durante acesso de engenharia e, quando aplicável, durante failover.</p>
<ul>
<li>Comparar carga real com a prevista.</li>
<li>Executar teste com tráfego acíclico representativo.</li>
<li>Verificar estabilidade do IO durante engenharia/diagnósticos.</li>
<li>Registrar baseline de utilização dos uplinks.</li>
<li>Repetir testes após expansão ou atualização relevante.</li>
</ul>
<p><strong>14. Conclusão<br />
</strong>O 10BASE-T1L oferece capacidade confortável para muitas aplicações de processo, mas robustez não deve ser inferida apenas dos 10 Mbit/s nominais. O projeto precisa relacionar ciclo, volume de dados, overhead, direções full-duplex, tráfego acíclico, jitter, QoS, uplinks e crescimento.</p>
<p>O resultado esperado do dimensionamento é um orçamento de comunicação documentado, com margem conhecida e hipóteses rastreáveis. Isso permite que futuras expansões sejam avaliadas quantitativamente, em vez de depender da percepção de que ainda existe &#8216;banda sobrando&#8217;.</p>
<p>&nbsp;</p>
<p><strong>Referências do documento-base</strong></p>
<ul>
<li>IEEE Std 802.3-2022, Clause 146 – 10BASE-T1L.</li>
<li>PROFIBUS &amp; PROFINET International – PROFINET specification.</li>
<li>FieldComm Group / ODVA / OPC Foundation / PI – Ethernet-APL Engineering Guideline.</li>
<li>Documentação dos Field Switches – capacidade de comutação, QoS e portas.</li>
<li>Artigos Técnicos César Cassiolato</li>
</ul>
<p><strong> </strong></p>
<p><em>(<strong>*</strong>) <strong>César Cassiolato</strong>, CEO da Vivace Process Instruments LTDA</em></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.profibus.org.br/noticia/dimensionamento-de-carga-e-performance-em-redes-ethernet-apl/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">13216</post-id>	</item>
		<item>
		<title>Migração de Redes PROFIBUS PA para Ethernet-APL: um guia de viabilidade e benefícios</title>
		<link>https://www.profibus.org.br/noticia/migracao-de-redes-profibus-pa-para-ethernet-apl-um-guia-de-viabilidade-e-beneficios/</link>
					<comments>https://www.profibus.org.br/noticia/migracao-de-redes-profibus-pa-para-ethernet-apl-um-guia-de-viabilidade-e-beneficios/#respond</comments>
		
		<dc:creator><![CDATA[Marketing]]></dc:creator>
		<pubDate>Wed, 09 Sep 2026 02:55:39 +0000</pubDate>
				<category><![CDATA[Artigo técnico]]></category>
		<guid isPermaLink="false">https://www.profibus.org.br/?p=13204</guid>

					<description><![CDATA[PEPPERL+FUCHS Modernizar a rede de campo da sua fábrica pode ocorrer de forma simplificada, mantendo a instrumentação de campo existente. O Ethernet-APL é o salto definitivo da comunicação industrial, levando a velocidade Ethernet diretamente para áreas seguras e áreas classificadas com total compatibilidade com a infraestrutura atual de quem já trabalha com PROFIBUS PA. A [&#8230;]]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><a href="https://www.pepperl-fuchs.com/pt-br" target="_blank" rel="noopener"><strong>PEPPERL+FUCHS</strong></a></p>
<p>Modernizar a rede de campo da sua fábrica pode ocorrer de forma simplificada, mantendo a instrumentação de campo existente. O Ethernet-APL é o salto definitivo da comunicação industrial, levando a velocidade Ethernet diretamente para áreas seguras e áreas classificadas com total compatibilidade com a infraestrutura atual de quem já trabalha com PROFIBUS PA.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-13206" src="https://www.profibus.org.br/wp-content/uploads/2026/09/Topologia-1.png" alt="" width="784" height="404" srcset="https://www.profibus.org.br/wp-content/uploads/2026/09/Topologia-1.png 1386w, https://www.profibus.org.br/wp-content/uploads/2026/09/Topologia-1-300x155.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/09/Topologia-1-1024x528.png 1024w, https://www.profibus.org.br/wp-content/uploads/2026/09/Topologia-1-768x396.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/09/Topologia-1-555x286.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/09/Topologia-1-1110x572.png 1110w, https://www.profibus.org.br/wp-content/uploads/2026/09/Topologia-1-600x309.png 600w, https://www.profibus.org.br/wp-content/uploads/2026/09/Topologia-1-1200x618.png 1200w" sizes="(max-width: 784px) 100vw, 784px" /></p>
<p><strong>A tecnologia Ethernet-APL na prática<br />
</strong>Padronizado globalmente sob a norma IEEE 802.3cg 10BASE-T1L, o Ethernet-APL atua como uma camada física avançada, desenvolvida especificamente para as demandas críticas da indústria de processos. Ele viabiliza o tráfego de protocolos Industrial Ethernet diretamente até os instrumentos de campo, fornecendo energia e dados em alta velocidade, por meio de um único par de fios.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-13205" src="https://www.profibus.org.br/wp-content/uploads/2026/09/PP1-scaled-e1788922059841.png" alt="" width="608" height="479" srcset="https://www.profibus.org.br/wp-content/uploads/2026/09/PP1-scaled-e1788922059841.png 2560w, https://www.profibus.org.br/wp-content/uploads/2026/09/PP1-scaled-e1788922059841-300x236.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/09/PP1-scaled-e1788922059841-1024x807.png 1024w, https://www.profibus.org.br/wp-content/uploads/2026/09/PP1-scaled-e1788922059841-768x605.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/09/PP1-scaled-e1788922059841-1536x1211.png 1536w, https://www.profibus.org.br/wp-content/uploads/2026/09/PP1-scaled-e1788922059841-2048x1614.png 2048w, https://www.profibus.org.br/wp-content/uploads/2026/09/PP1-scaled-e1788922059841-555x437.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/09/PP1-scaled-e1788922059841-1110x875.png 1110w, https://www.profibus.org.br/wp-content/uploads/2026/09/PP1-scaled-e1788922059841-600x473.png 600w, https://www.profibus.org.br/wp-content/uploads/2026/09/PP1-scaled-e1788922059841-1200x946.png 1200w" sizes="(max-width: 608px) 100vw, 608px" /></p>
<p>Além de trazer essas novas e avançadas funções, também é possível migrar de uma topologia PROFIBUS PA para Ethernet-APL de maneira facilitada, graças à funcionalidade Proxy PA, que permite que as migrações de instrumentos sejam feitas de maneira gradativa, operando de forma híbrida com instrumentos.</p>
<ul>
<li><strong>Tecnologia Proxy PA</strong>: o switch atua como um dispositivo híbrido. Em um modelo de 8, 16 ou 24 portas, é possível conectar simultaneamente instrumentos PROFIBUS PA e novos instrumentos Ethernet-APL em portas individualizadas e intrinsecamente seguras.</li>
<li><strong>Topologia muito mais enxuta e simples</strong>: terminadores, protetores de segmento ou field barriers não são mais necessários, tampouco o risco dos erros de instalação comuns do PROFIBUS PA. O instrumento conecta-se diretamente na porta do switch, dispensando terminação ou derivações.</li>
<li><strong>Conexão individualizada</strong>: cada instrumento tem seu cabo físico dedicado ligado diretamente a uma porta do Switch de Campo, isolando falhas por canal e prevenindo que problemas em um instrumento derrubem o segmento.</li>
<li><strong>Acesso direto</strong>: instrumentos APL possuem IP próprio e Webserver integrado, viabilizando parametrização avançada e intervenções remotas isoladas por dispositivo, por meio de diagnósticos avançados e individuais.</li>
<li><strong>Flexibilidade em expansões</strong>: havendo portas disponíveis no switch, a inclusão de um novo instrumento ocorre de forma plug-and-play, dispensando recálculos complexos de consumo do barramento.</li>
<li><strong>Maior segurança</strong>: proteção contra curto-circuito, inversão de polaridade de fios ou nós repetidos.</li>
</ul>
<table width="553">
<tbody>
<tr>
<td width="151"><strong>Característica</strong></td>
<td width="178"><strong>PROFIBUS PA</strong></td>
<td width="162"><strong>Ethernet-APL</strong></td>
<td width="198"><strong>Ganho</strong></td>
</tr>
<tr>
<td width="151">Velocidade</td>
<td width="178">31,25 kbps</td>
<td width="162">10.000 kbps</td>
<td width="198"> 300x mais rápido; viabiliza manutenção preditiva real e otimiza os tempos de comissionamento.</td>
</tr>
<tr>
<td width="151">Cabo de campo</td>
<td width="178">Par trançado tipo A</td>
<td width="162">Par trançado tipo A</td>
<td width="198">Alto reaproveitamento.</td>
</tr>
<tr>
<td width="151">Parametrização</p>
<p>(200 inst.)</td>
<td width="178">Aprox. 10 horas</td>
<td width="162">Aprox. 33 minutos</td>
<td width="198">Redução de 98% no tempo de engenharia e paradas.</td>
</tr>
<tr>
<td width="151">Segurança Intrínseca</td>
<td width="178">Modelo FISCO</td>
<td width="162">Padrão 2-WISE</td>
<td width="198">Sem cálculos de parâmetros de entidade e com segurança em áreas classificadas.</td>
</tr>
<tr>
<td width="151">Hardware até o instrumento</td>
<td width="178">Gateways e acopladores, barreiras de campo, protetores de segmento, derivadores, terminadores.</td>
<td width="162">Switch APL (com Proxy) com conexão direta ao instrumento.</td>
<td width="198">Menos componentes, menor risco de instalação, mais disponibilidade.</td>
</tr>
<tr>
<td width="151">Distância até o instrumento</td>
<td width="178">Limitada pela quantidade de instrumentos.<br />
1-12: 120 m<br />
13-14: 90 m<br />
15-18: 60 m<br />
19-24: 30 m<br />
25-32: 1 m</td>
<td width="162">120 m para instrumentos PA sem limitação pela quantidade de nós;<br />
200 m para instrumentos Ethernet-APL</td>
<td width="198">Maior autonomia para o projeto da planta.</td>
</tr>
</tbody>
</table>
<p>Modernizar para Ethernet-APL com switches Proxy otimiza seus investimentos em instrumentação e prepara sua fábrica para a Indústria 4.0 de forma segura, gradual e econômica.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-13207" src="https://www.profibus.org.br/wp-content/uploads/2026/09/Topologia-2.png" alt="" width="790" height="343" srcset="https://www.profibus.org.br/wp-content/uploads/2026/09/Topologia-2.png 1489w, https://www.profibus.org.br/wp-content/uploads/2026/09/Topologia-2-300x130.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/09/Topologia-2-1024x445.png 1024w, https://www.profibus.org.br/wp-content/uploads/2026/09/Topologia-2-768x334.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/09/Topologia-2-555x241.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/09/Topologia-2-1110x482.png 1110w, https://www.profibus.org.br/wp-content/uploads/2026/09/Topologia-2-600x261.png 600w, https://www.profibus.org.br/wp-content/uploads/2026/09/Topologia-2-1200x521.png 1200w" sizes="(max-width: 790px) 100vw, 790px" /></p>
<p>Saiba mais sobre essa <a href="https://www.pepperl-fuchs.com/pt-br/trends/tendencias/ethernet-apl-gp55679" target="_blank" rel="noopener">tecnologia e os Switches APL</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.profibus.org.br/noticia/migracao-de-redes-profibus-pa-para-ethernet-apl-um-guia-de-viabilidade-e-beneficios/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">13204</post-id>	</item>
		<item>
		<title>Ethernet-APL: Diagnóstico avançado da camada Física &#038; Confiabilidade</title>
		<link>https://www.profibus.org.br/noticia/ethernet-apl-diagnostico-avancado-da-camada-fisica-confiabilidade/</link>
					<comments>https://www.profibus.org.br/noticia/ethernet-apl-diagnostico-avancado-da-camada-fisica-confiabilidade/#respond</comments>
		
		<dc:creator><![CDATA[Marketing]]></dc:creator>
		<pubDate>Mon, 10 Aug 2026 02:23:27 +0000</pubDate>
				<category><![CDATA[Artigo técnico]]></category>
		<guid isPermaLink="false">https://www.profibus.org.br/?p=13156</guid>

					<description><![CDATA[Parâmetros, métodos e correlação entre defeitos e sintomas em redes 10BASE-T1L para automação de processos César Cassiolato (*) Resumo O Ethernet-APL (Advanced Physical Layer) representa a evolução da comunicação Ethernet para a automação de processos, permitindo taxas de 10 Mbit/s em full-duplex sobre um único par trançado, com alcance de até 1000 m e suporte [&#8230;]]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><strong><em>Parâmetros, métodos e correlação entre defeitos e sintomas em redes 10BASE-T1L para automação de processos</em></strong></p>
<p style="text-align: right;"><strong><em>César Cassiolato (*)</em></strong></p>
<p><strong>Resumo</strong><br />
O Ethernet-APL (Advanced Physical Layer) representa a evolução da comunicação Ethernet para a automação de processos, permitindo taxas de 10 Mbit/s em full-duplex sobre um único par trançado, com alcance de até 1000 m e suporte a segurança intrínseca. A robustez da camada física 10BASE-T1L (IEEE 802.3cg) depende criticamente da qualidade do canal de transmissão. Este artigo apresenta uma análise aprofundada dos principais parâmetros de diagnóstico da camada física: BER, SNR, diagrama de olho, Return Loss, TCL, ELTCTL, jitter, reflexões, TDR e resistência de loop; estabelecendo a correlação causal entre defeitos físicos, como conectores oxidados, cabos danificados e desequilíbrio do par, e os sintomas observáveis até a queda do link. São fornecidas tabelas de mapeamento defeito→sintoma, diagramas, fluxogramas e orientações práticas para manutenção preditiva e comissionamento.</p>
<p><strong>1.   Introdução</strong><br />
A digitalização de plantas de processo exige comunicação de alta largura de banda até o campo, incluindo áreas classificadas (Zonas 0/1/2). O Ethernet-APL, resultado da colaboração entre FieldComm Group, ODVA, OPC Foundation e PROFIBUS &amp; PROFINET International, padroniza o uso do 10BASE-T1L com perfis de porta, classes de potência e requisitos de compatibilidade eletromagnética e segurança intrínseca (IEC TS 63444).</p>
<p>Diferentemente de fieldbuses clássicos (Foundation Fieldbus H1, PROFIBUS PA) que operam a 31,25 kbit/s, o Ethernet-APL opera a 10 Mbit/s com codificação PAM-3 e equalização adaptativa. Isso torna o canal muito mais sensível a imperfeições de instalação: descontinuidades de impedância, assimetrias de par, ruído de modo comum e envelhecimento de cabos. O diagnóstico avançado da camada física deixa de ser opcional e passa a ser requisito essencial para disponibilidade e manutenção preditiva.</p>
<p>Historicamente, a recomendação NAMUR NE 123 orientava o diagnóstico de fieldbuses clássicos com base em quatro parâmetros: nível de sinal, ruído, jitter e desequilíbrios. No Ethernet-APL, esses conceitos são preservados e ampliados por métricas digitais nativas dos PHYs, como MSE, SQI e contadores internos de erro, além de recursos ativos como TDR on-chip. Essa combinação permite detectar a degradação do meio físico e auxiliar na localização da região provável do defeito.</p>
<p><strong>1.1 Objetivos do artigo</strong><br />
•  Apresentar os parâmetros de diagnóstico definidos ou suportados por PHYs 10BASE-T1L e especificações APL.<br />
•  Explicar o significado físico e o impacto de cada métrica na qualidade do link.<br />
•  Estabelecer cadeias causais claras: defeito físico → efeito elétrico → degradação de sinal → aumento de BER → falha de link.<br />
•  Fornecer orientações práticas de interpretação, fluxogramas de troubleshooting e ações corretivas.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-13157" src="https://www.profibus.org.br/wp-content/uploads/2026/08/1.png" alt="" width="772" height="322" srcset="https://www.profibus.org.br/wp-content/uploads/2026/08/1.png 1251w, https://www.profibus.org.br/wp-content/uploads/2026/08/1-300x125.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/08/1-1024x427.png 1024w, https://www.profibus.org.br/wp-content/uploads/2026/08/1-768x320.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/08/1-555x232.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/08/1-1110x463.png 1110w, https://www.profibus.org.br/wp-content/uploads/2026/08/1-600x250.png 600w, https://www.profibus.org.br/wp-content/uploads/2026/08/1-1200x501.png 1200w" sizes="(max-width: 772px) 100vw, 772px" /></p>
<p style="text-align: center;"><em>Figura 1 – Topologia típica Ethernet-APL (Trunk + Spur) com diagnóstico por porta.</em></p>
<p><strong>2.  A camada física 10BASE-T1L no contexto APL</strong><br />
O 10BASE-T1L (IEEE Std 802.3-2022, Clause 146) utiliza um único par balanceado, transmissão full-duplex com cancelamento de eco, símbolos PAM-3 a 7,5 MBd e equalização DFE (Decision Feedback Equalizer). O alcance nominal é de até 1000 m com cabo de categoria adequada (inserção de perda limitada). O Ethernet-APL adiciona:</p>
<p>•  Perfis de porta (Trunk 2,4 Vpp e Spur 1,0 Vpp) com classes de potência (A/B/C para spur, 3/4 para trunk).<br />
•  Requisitos de Return Loss e Coupling Attenuation mais rigorosos que o IEEE puro (tipicamente +6 dB de margem no RL de cabo).<br />
•  Suporte a segurança intrínseca (Ex i) e proteção de surto (TVS 25 A).<br />
•  Polaridade automática e auto-negociação (Clause 98).<br />
• Requisitos de Insertion Loss, Return Loss, balanceamento e compatibilidade eletromagnética aplicáveis ao cabo e ao canal, de acordo com o perfil Ethernet-APL adotado.</p>
<p>A qualidade do link é monitorada em tempo real por registradores do PHY (MSE, SNR, SQI, contadores de erro de slicer) e por mecanismos de teste ativos (TDR, PRBS, modos de teste PMA). A combinação desses recursos transforma cada porta em um sensor de integridade do meio físico.</p>
<p><strong>2.1 Principais parâmetros do meio físico para Ethernet-APL / 10BASE-T1L</strong></p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-13132 " src="https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_01-e1786326345251.png" alt="" width="792" height="611" srcset="https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_01-e1786326345251.png 2400w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_01-e1786326345251-300x232.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_01-e1786326345251-1024x790.png 1024w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_01-e1786326345251-768x593.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_01-e1786326345251-1536x1185.png 1536w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_01-e1786326345251-2048x1580.png 2048w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_01-e1786326345251-555x428.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_01-e1786326345251-1110x857.png 1110w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_01-e1786326345251-600x463.png 600w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_01-e1786326345251-1200x926.png 1200w" sizes="(max-width: 792px) 100vw, 792px" /></p>
<p style="text-align: center;"><em>Tabela 1 – Principais parâmetros do meio físico para Ethernet-APL / 10BASE-T1L<br />
</em><em>Os limites aplicáveis dependem da especificação Ethernet-APL, do perfil de porta, da topologia, do cabo utilizado, das condições ambientais e do PHY. Comprimento, isoladamente, não determina a conformidade do enlace. A avaliação deve considerar a análise completa do canal, incluindo parâmetros de transmissão, balanceamento, alimentação e instalação.</em></p>
<p><strong>3. Parâmetros de diagnóstico avançado</strong><br />
<strong>3.1 Bit Error Rate (BER)</strong><br />
A Taxa de Erro de Bit (BER) é a razão entre bits incorretos e bits totais transmitidos. Nas especificações Ethernet-APL / 10BASE-T1L, o receptor deve manter BER &lt; 10−9 sob condições de ruído e canal de pior caso (Insertion Loss máximo + ruído AWGN + ripple de potência + spurs). Em operação, BER é estimado indiretamente via contadores de erros de frame (CRC), erros de símbolo ou via métricas internas do equalizador (MSE).</p>
<p>Um aumento persistente da BER, mesmo com o link ativo, indica redução da margem de comunicação e pode anteceder a perda do link. Como critério de manutenção, uma elevação sustentada da BER estimada em relação ao baseline deve ser investigada, especialmente quando acompanhada de redução do SNR ou degradação de outras métricas do PHY. Nos testes de conformidade citados neste artigo, o DUT deve atender ao limite de BER definido para o canal e as condições de ruído especificadas.</p>
<p><strong>3.2 Signal-to-Noise Ratio (SNR) e Mean Squared Error (MSE)</strong><br />
O SNR mede a relação entre a potência do sinal útil e a potência do ruído + interferência no ponto de decisão do receptor. Em PHYs 10BASE-T1L modernos (ex.: ADI ADIN1100/1110/2111, TI DP83TD510E), o MSE do equalizador é mapeado diretamente para SNR e para um indicador de qualidade de sinal (SQI) em escala discreta (0–7 ou similar). O MSE é calculado a partir do erro residual após o DFE.</p>
<p style="text-align: center;"><img loading="lazy" decoding="async" class="aligncenter wp-image-13133 " src="https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_02-e1786326453678.png" alt="" width="791" height="178" srcset="https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_02-e1786326453678.png 2400w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_02-e1786326453678-300x68.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_02-e1786326453678-1024x230.png 1024w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_02-e1786326453678-768x173.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_02-e1786326453678-1536x346.png 1536w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_02-e1786326453678-2048x461.png 2048w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_02-e1786326453678-555x125.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_02-e1786326453678-1110x250.png 1110w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_02-e1786326453678-600x135.png 600w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_02-e1786326453678-1200x270.png 1200w" sizes="(max-width: 791px) 100vw, 791px" /><em>Tabela 2 – Exemplo ilustrativo de classificação da qualidade do link a partir do SNR. Os valores apresentados são referências de análise; os limites efetivos dependem do PHY, das condições do canal e dos critérios definidos pelo fabricante.</em></p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-13158" src="https://www.profibus.org.br/wp-content/uploads/2026/08/2.png" alt="" width="752" height="507" srcset="https://www.profibus.org.br/wp-content/uploads/2026/08/2.png 1515w, https://www.profibus.org.br/wp-content/uploads/2026/08/2-300x202.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/08/2-1024x690.png 1024w, https://www.profibus.org.br/wp-content/uploads/2026/08/2-768x518.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/08/2-555x374.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/08/2-1110x748.png 1110w, https://www.profibus.org.br/wp-content/uploads/2026/08/2-600x404.png 600w, https://www.profibus.org.br/wp-content/uploads/2026/08/2-1200x809.png 1200w" sizes="(max-width: 752px) 100vw, 752px" /></p>
<p style="text-align: center;"><em>Figura 2 – Relação conceitual entre SNR e BER em 10BASE-T1L / Ethernet-APL.</em></p>
<p>O monitoramento contínuo do SNR permite construir tendências e a emissão de alarmes de manutenção preditiva muito antes da falha completa do link. Valores de SQI ou equivalentes podem ser mapeados para indicadores NAMUR NE 107 (Maintenance Required, Out of Spec etc.).</p>
<p>A figura 2 apresenta a relação entre SNR (Signal-to-Noise Ratio) e BER (Bit Error Rate) em enlaces 10BASE-T1L / Ethernet-APL. O objetivo principal é mostrar que, à medida que a margem de sinal aumenta, a probabilidade de erro de bit tende a diminuir, permitindo avaliar não apenas se o link está ativo, mas também o quanto ele está afastado de uma condição marginal.</p>
<p>O eixo horizontal representa o SNR em dB. Quanto maior esse valor, maior a relação entre a potência do sinal útil e o ruído/interferência presentes no receptor. O eixo vertical representa a BER, em escala logarítmica. Por isso, cada divisão representa ordens de grandeza: passar de 10⁻⁷ para 10⁻⁹, por exemplo, corresponde a uma redução de 100 vezes na taxa de erro.</p>
<p>A curva azul mostra uma tendência conceitual SNR × BER: com SNR baixo, a BER tende a ser maior; com SNR crescente, a BER tende a cair rapidamente. Essa curva não deve ser interpretada como uma característica normativa universal de todos os PHYs 10BASE-T1L. Ela representa uma relação ilustrativa, pois o comportamento real depende do transceptor, do canal, da equalização, do jitter, das reflexões, da interferência eletromagnética e das condições de operação.</p>
<p>A linha horizontal vermelha em BER = 10⁻⁹ é usada como referência visual. Uma BER de 10⁻⁹ corresponde, estatisticamente, a aproximadamente um bit errado a cada um bilhão de bits transmitidos, nas condições em que a BER foi medida. Valores abaixo dessa linha representam uma taxa de erro ainda menor.</p>
<p>Já a linha vertical verde em 20,5 dB foi mantida apenas como referência ilustrativa de SNR, e não como um limite normativo universal. Essa distinção é importante: o gráfico não afirma que todo enlace acima de 20,5 dB necessariamente apresenta BER inferior a 10⁻⁹, nem que um enlace abaixo desse valor esteja automaticamente fora de especificação.</p>
<p>As três regiões coloridas tornam a interpretação mais didática. A região vermelha, à esquerda, representa uma condição de margem insuficiente, em que o sistema está mais suscetível a ruído, interferências, reflexões e variações do ambiente. Nessa região, é recomendável verificar conectores, emendas, cabos, aterramento, blindagem e fontes externas de EMI.</p>
<p>A região amarela representa uma zona de transição. O link pode permanecer operacional, porém com menor margem. Essa é justamente a faixa em que o acompanhamento por tendência se torna mais importante. Uma medição isolada pode não caracterizar um problema, mas uma queda progressiva do SNR em relação ao baseline pode indicar degradação do meio físico.</p>
<p>A região verde representa uma condição de maior margem. Nessa situação, a comunicação tende a ser mais robusta frente a variações de ruído, temperatura, interferência e pequenas alterações do canal. Mesmo assim, o valor absoluto não substitui o acompanhamento histórico.</p>
<p>Os pontos destacados no gráfico ajudam a visualizar essa ideia. Um ponto em torno de 16 dB representa uma condição de margem reduzida e BER relativamente elevada. Próximo de 20,5 dB, a condição é tratada como transicional. Em torno de 26 dB, a figura representa uma situação de margem confortável e BER muito baixa.</p>
<p>O aspecto mais importante para manutenção preditiva é observar a evolução temporal. Imagine uma porta que, no comissionamento, apresente SNR de 26 dB e, após alguns anos, passe para 23 dB e depois para 21 dB. Mesmo que o link continue ativo, a redução progressiva da margem pode indicar envelhecimento do cabo, oxidação de conexão, aumento de interferência, alteração de impedância ou outro mecanismo de degradação.</p>
<p>Por isso, a interpretação ideal não é apenas: “O SNR está acima ou abaixo de um limite?”<br />
Mas sim: “Como o SNR atual se compara ao baseline dessa porta e como ele está evoluindo?”</p>
<p>Quando a queda de SNR aparece acompanhada de outras evidências — como aumento dos contadores de erro, piora do MSE/SQI, alteração da resistência de loop ou novas reflexões no TDR — a confiança no diagnóstico aumenta significativamente.</p>
<p>A mensagem central da figura pode ser resumida assim:<br />
maior SNR → maior margem de decisão do receptor → menor probabilidade de erro → maior robustez da comunicação.</p>
<p>E, do ponto de vista de manutenção:<br />
baseline + tendência + correlação entre métricas é muito mais útil do que depender de um único valor instantâneo de SNR ou BER.</p>
<p><strong>3.3 Diagrama de olho (Eye Diagram)</strong><br />
O diagrama de olho é a sobreposição de múltiplos períodos de símbolo no domínio do tempo. Em 10BASE-T1L a modulação é PAM-3 (três níveis: −1, 0, +1), portanto o olho apresenta duas aberturas verticais. A abertura vertical está diretamente relacionada ao SNR residual após equalização; a abertura horizontal relaciona-se ao jitter e à margem de amostragem.</p>
<p>Em aplicações de campo, essas métricas internas fornecem indicadores operacionais relacionados à qualidade que seria observada no eye diagram.</p>
<p><img loading="lazy" decoding="async" class="wp-image-13159 aligncenter" src="https://www.profibus.org.br/wp-content/uploads/2026/08/3.png" alt="" width="749" height="499" srcset="https://www.profibus.org.br/wp-content/uploads/2026/08/3.png 1211w, https://www.profibus.org.br/wp-content/uploads/2026/08/3-300x200.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/08/3-1024x682.png 1024w, https://www.profibus.org.br/wp-content/uploads/2026/08/3-768x512.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/08/3-555x370.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/08/3-1110x740.png 1110w, https://www.profibus.org.br/wp-content/uploads/2026/08/3-600x400.png 600w, https://www.profibus.org.br/wp-content/uploads/2026/08/3-1200x800.png 1200w" sizes="(max-width: 749px) 100vw, 749px" /></p>
<p style="text-align: center;"><em>Figura 3 – Conceito de diagrama de olho: aberto (bom SNR/jitter) versus fechado (degradado).</em></p>
<p><strong>3.4 Return Loss (Perda de retorno)</strong><br />
Return Loss (RL) quantifica a fração de potência refletida devido a descontinuidades de impedância (conectores, emendas, variação de dielétrico, terminações). É definido como:</p>
<p>RL (dB) = −20 · log₁₀|Γ|, onde Γ = (ZL − Z₀) / (ZL + Z₀) é o coeficiente de reflexão.</p>
<p>Valores altos de RL (ex.: &gt; 20 dB) significam baixa reflexão e são desejáveis. A especificação Ethernet-APL exige limites de RL de cabo mais rigorosos que o IEEE 802.3cg (tipicamente +6 dB de margem) para acomodar múltiplas reflexões em segmentos curtos e a presença de power coupling. No MDI do dispositivo, o teste de Return Loss faz parte dos testes de conformidade do transmissor (APL.146.1.6). Reflexões não canceladas pelo DFE reduzem a abertura do olho e elevam o BER.</p>
<p style="text-align: center;"><img loading="lazy" decoding="async" class="aligncenter wp-image-13160" src="https://www.profibus.org.br/wp-content/uploads/2026/08/4.png" alt="" width="722" height="390" srcset="https://www.profibus.org.br/wp-content/uploads/2026/08/4.png 1156w, https://www.profibus.org.br/wp-content/uploads/2026/08/4-300x162.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/08/4-1024x553.png 1024w, https://www.profibus.org.br/wp-content/uploads/2026/08/4-768x415.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/08/4-555x300.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/08/4-1110x599.png 1110w, https://www.profibus.org.br/wp-content/uploads/2026/08/4-600x324.png 600w" sizes="(max-width: 722px) 100vw, 722px" /></p>
<p style="text-align: center;"><em>Figura 4 – Limites de Return Loss (IEEE vs. APL) e exemplos de cabos bom/ruim.</em></p>
<p><strong>3.5 TCL e ELTCTL (Conversão de Modo)</strong><br />
TCL (Transverse Conversion Loss) caracteriza a conversão de sinal diferencial para modo comum ao longo do cabo ou conector. Essa conversão decorre de assimetrias geométricas ou de impedância entre os dois condutores do par. Valores baixos de TCL indicam maior conversão indesejada entre os modos diferencial e comum, aumentando a emissão e a suscetibilidade a interferências de modo comum.</p>
<p>ELTCTL (Equal Level Transverse Conversion Transfer Loss) caracteriza a transferência associada à conversão de modo ao longo do canal, permitindo avaliar como desequilíbrios do par favorecem a transformação entre componentes diferenciais e de modo comum. Em conjunto, TCL e ELTCTL são importantes em ambientes industriais sujeitos a elevado ruído eletromagnético e em enlaces de maior comprimento. Os limites aplicáveis devem ser verificados nas especificações pertinentes ao cabo, ao canal e ao ambiente de instalação.</p>
<p>Defeitos típicos que degradam TCL/ELTCTL: torção irregular do par, conectores com pinos desbalanceados, dano mecânico assimétrico no cabo, ou uso de cabo não-balanceado. Em campo, a degradação de TCL manifesta-se frequentemente como SNR que piora quando fontes de EMI (inversores, motores, soldas) estão ativas.</p>
<p><strong>3.6 Jitter</strong><br />
Jitter é a variação temporal da posição dos flancos do sinal em relação a um relógio ideal. No 10BASE-T1L, o teste de Transmitter Timing Jitter (APL.146.1.3) verifica que o jitter do transmissor permanece dentro de limites definidos (Test Mode 1). No receptor, o jitter residual reduz a abertura horizontal do olho e aumenta a probabilidade de erro de amostragem.</p>
<p>Fontes de jitter: ruído de fase do PLL local, inter-symbol interference residual após equalização, reflexões próximas (que o DFE pode não cancelar completamente) e interferências de baixa frequência (ripple de potência nas linhas de alimentação). Jitter excessivo aparece frequentemente junto com redução de SNR e pode ser o fator limitante em links longos com equalização agressiva.</p>
<p><strong>3.7 Reflexões e TDR (Time Domain Reflectometry)</strong><br />
Reflexões ocorrem sempre que a impedância característica do meio muda. Em regime estacionário, elas degradam o Return Loss e podem reduzir a margem do link. No domínio do tempo, o TDR aplica um sinal de teste ao par e analisa as reflexões retornadas. A polaridade e a amplitude da reflexão ajudam a caracterizar a descontinuidade, enquanto o atraso, associado ao tempo de voo, permite estimar sua posição:</p>
<p>•  Reflexão positiva → circuito aberto (open) ou aumento de impedância (ex.: conector solto).<br />
•  Reflexão negativa → curto-circuito (short) ou redução de impedância.<br />
•  Múltiplas reflexões pequenas → emendas, conectores intermediários ou variação de cabo.</p>
<p>Alguns PHYs 10BASE-T1L implementam recursos de TDR on-chip para auxiliar na localização de circuitos abertos, curtos e outras descontinuidades. A resolução, o alcance, a precisão e as condições de execução dependem do PHY, do algoritmo, do cabo e do modo de teste utilizado. Por isso, os resultados devem ser interpretados de acordo com a documentação do componente e correlacionados com outras métricas do enlace.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-13161" src="https://www.profibus.org.br/wp-content/uploads/2026/08/5.jpg" alt="" width="758" height="265" srcset="https://www.profibus.org.br/wp-content/uploads/2026/08/5.jpg 1608w, https://www.profibus.org.br/wp-content/uploads/2026/08/5-300x105.jpg 300w, https://www.profibus.org.br/wp-content/uploads/2026/08/5-1024x357.jpg 1024w, https://www.profibus.org.br/wp-content/uploads/2026/08/5-768x268.jpg 768w, https://www.profibus.org.br/wp-content/uploads/2026/08/5-1536x536.jpg 1536w, https://www.profibus.org.br/wp-content/uploads/2026/08/5-555x194.jpg 555w, https://www.profibus.org.br/wp-content/uploads/2026/08/5-1110x387.jpg 1110w, https://www.profibus.org.br/wp-content/uploads/2026/08/5-600x209.jpg 600w, https://www.profibus.org.br/wp-content/uploads/2026/08/5-1200x419.jpg 1200w" sizes="(max-width: 758px) 100vw, 758px" /></p>
<p style="text-align: center;"> <em>Figura 5 – Assinaturas típicas de TDR: cabo saudável, open e short.</em></p>
<p>A figura 5 apresenta, de maneira didática, como um TDR (Time Domain Reflectometry – Reflectometria no Domínio do Tempo) pode distinguir diferentes condições do meio físico a partir das reflexões produzidas por mudanças de impedância. Os três gráficos representam um cabo saudável, um circuito aberto (open) e um curto-circuito (short).</p>
<p><strong>3.7.1 O que o TDR está medindo?</strong><br />
O princípio do TDR é semelhante ao de um radar aplicado ao cabo. O instrumento injeta um sinal de teste no par e observa a energia refletida ao longo do tempo.</p>
<p>Em um cabo uniforme, cuja impedância característica permanece aproximadamente constante, há pouca energia refletida. Quando o sinal encontra uma descontinuidade de impedância, parte da energia retorna ao ponto de medição.</p>
<p>O tempo transcorrido entre a transmissão e a chegada da reflexão permite estimar a posição da descontinuidade:</p>
<p><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-13164" src="https://www.profibus.org.br/wp-content/uploads/2026/08/f1.jpg" alt="" width="97" height="49" /><br />
onde d é a distância até a descontinuidade, vₚ é a velocidade de propagação no cabo e Δt é o tempo de ida e volta do sinal. A divisão por 2 ocorre porque o sinal percorre o caminho até o defeito e retorna.</p>
<p>Portanto, o TDR fornece duas informações fundamentais: a posição aproximada da anomalia e a natureza da alteração de impedância.</p>
<p><strong>3.7.2 Cabo saudável — sem reflexão significativa</strong><br />
O gráfico da esquerda representa o comportamento esperado de um cabo em boas condições.</p>
<p>A amplitude refletida permanece próxima de zero. As pequenas oscilações mostradas no início representam imperfeições residuais, ruído ou resposta do próprio sistema de medição, mas não existe uma reflexão suficientemente significativa que caracterize uma descontinuidade importante.</p>
<p>Em termos físicos:<br />
impedância relativamente uniforme → pouca reflexão → sinal refletido próximo de zero.</p>
<p>Isso não significa que o cabo seja absolutamente perfeito. Conectores, transições e pequenas variações construtivas podem produzir reflexões discretas. O importante é que não apareçam eventos incompatíveis com os limites e com o baseline da instalação.</p>
<p><strong>3.7.3 Circuito aberto — reflexão positiva</strong><br />
O gráfico central representa um circuito aberto, como poderia ocorrer com um condutor rompido, terminal desconectado ou conector sem contato.</p>
<p>Quando a onda encontra uma impedância muito superior à impedância característica do cabo, ocorre uma reflexão positiva.</p>
<p>Isso pode ser entendido pelo coeficiente de reflexão:<br />
<img loading="lazy" decoding="async" class="size-full wp-image-13165 aligncenter" src="https://www.profibus.org.br/wp-content/uploads/2026/08/f2.jpg" alt="" width="108" height="46" /><br />
Para um circuito aberto:<img loading="lazy" decoding="async" class="aligncenter size-full wp-image-13166" src="https://www.profibus.org.br/wp-content/uploads/2026/08/f3.jpg" alt="" width="136" height="36" /></p>
<p>Ou seja, idealmente, a reflexão apresenta a mesma polaridade do sinal incidente.</p>
<p>Na figura, o grande pico positivo próximo da posição 4 indica onde se encontra a descontinuidade. Em um equipamento real, essa posição seria convertida em metros a partir do tempo de propagação e do fator de velocidade do cabo.</p>
<p>Assim: pico positivo → aumento de impedância → possível circuito aberto.</p>
<p><strong>3.7.4 Curto-circuito — reflexão negativa</strong><br />
O gráfico da direita apresenta a situação oposta.</p>
<p>Em um curto entre os condutores:</p>
<p><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-13167" src="https://www.profibus.org.br/wp-content/uploads/2026/08/f4.jpg" alt="" width="675" height="124" srcset="https://www.profibus.org.br/wp-content/uploads/2026/08/f4.jpg 675w, https://www.profibus.org.br/wp-content/uploads/2026/08/f4-300x55.jpg 300w, https://www.profibus.org.br/wp-content/uploads/2026/08/f4-555x102.jpg 555w, https://www.profibus.org.br/wp-content/uploads/2026/08/f4-600x110.jpg 600w" sizes="(max-width: 675px) 100vw, 675px" /></p>
<p>A energia refletida retorna com polaridade invertida, produzindo o pico negativo observado aproximadamente na posição 6.</p>
<p>A interpretação é: pico negativo → redução de impedância → possível curto-circuito.</p>
<p>Da mesma maneira que no circuito aberto, a posição horizontal do evento permite estimar a distância até o defeito.</p>
<p><strong>3.7.5 O que ocorre com defeitos menos extremos</strong><br />
Na instalação real de Ethernet-APL, nem toda anomalia será um open ou short completo. O TDR também pode revelar alterações intermediárias.</p>
<p>Um conector oxidado, emenda inadequada, terminal frouxo, esmagamento do cabo ou mudança local de impedância pode produzir reflexões menores. Nesse caso, a amplitude e a polaridade ajudam a interpretar se houve aumento ou redução local da impedância, enquanto a posição do evento ajuda a localizar onde investigar.</p>
<p>Por exemplo, uma reflexão positiva pequena não significa necessariamente circuito aberto. Pode representar simplesmente uma transição para uma impedância maior. Da mesma forma, uma reflexão negativa pequena pode indicar uma redução localizada de impedância sem que exista um curto completo.</p>
<p><strong>3.7.6 Relação com Ethernet-APL</strong><br />
No diagnóstico de uma rede Ethernet-APL, o TDR é particularmente interessante porque permite sair de uma informação genérica, como “a qualidade do link está ruim”, para uma indicação física do tipo: “existe uma descontinuidade aproximadamente a determinada distância desta porta”.</p>
<p>Ele complementa métricas como SNR, MSE, SQI, Return Loss e contadores de erro.</p>
<p>Por exemplo:<br />
SNR reduzido + reflexão localizada no TDR + aumento da resistência de loop pode indicar uma conexão ou região do cabo que merece inspeção.</p>
<p>Já um Link Down + grande reflexão positiva sugere investigar circuito aberto ou desconexão próximo da distância indicada.</p>
<p><strong>3.7.7 Como interpretar os três gráficos</strong><br />
A mensagem principal da figura pode ser sintetizada assim:<br />
Cabo saudável: reflexão ≈ 0 → impedância uniforme.<br />
Open: reflexão positiva → impedância aumentou significativamente.<br />
Short: reflexão negativa → impedância caiu significativamente.</p>
<p>E a posição horizontal da reflexão representa o tempo de voo e, depois da conversão adequada, a distância aproximada até a descontinuidade.</p>
<p>A forma da assinatura depende do cabo, comprimento, velocidade de propagação, largura do pulso, resolução do TDR, conectores e múltiplas reflexões. Portanto, não se deve interpretar todo pico positivo como um open ou todo pico negativo como um short; o resultado deve ser correlacionado com outras medições e com o baseline do segmento.</p>
<p><strong>3.8 Resistência de loop (Loop resistance)</strong><br />
A resistência CC do loop, considerando ida e volta do par, é uma medida simples e útil de integridade do cabo e da qualidade das conexões. Variações ao longo do tempo indicam corrosão, afrouxamento de terminais ou degradação do condutor. Além disso, a queda de tensão resistiva limita o orçamento de potência em segmentos alimentados (PoDL / SPoE). Switches e dispositivos APL frequentemente reportam tensão e corrente de porta, permitindo inferir a resistência efetiva.</p>
<p>A resistência de loop depende da seção dos condutores, do material, do comprimento e da temperatura. Para fins de diagnóstico, seu maior valor está na comparação com o baseline registrado durante o comissionamento. Um aumento súbito ou gradual de Loop R, especialmente quando correlacionado com redução de SNR ou aumento de erros, pode indicar problemas de contato, como oxidação, vibração, torque insuficiente ou degradação do condutor.</p>
<p><strong>4. Correlação defeito físico → sintoma</strong><br />
A força do diagnóstico avançado reside na capacidade de mapear sintomas elétricos de volta à causa física raiz. A Figura 6 e a Tabela 3 sintetizam as cadeias causais mais comuns em instalações Ethernet-APL.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-13162" src="https://www.profibus.org.br/wp-content/uploads/2026/08/6.png" alt="" width="653" height="325" srcset="https://www.profibus.org.br/wp-content/uploads/2026/08/6.png 926w, https://www.profibus.org.br/wp-content/uploads/2026/08/6-300x149.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/08/6-768x382.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/08/6-555x276.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/08/6-600x299.png 600w" sizes="(max-width: 653px) 100vw, 653px" /></p>
<p style="text-align: center;"><em>Figura 6 – Exemplo de cadeia causal completa: conector oxidado até queda do link.</em></p>
<p><strong>4.1 Tabela de mapeamento defeito → sintomas</strong></p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-13134 " src="https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_03-e1786327969567.png" alt="" width="769" height="579" srcset="https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_03-e1786327969567.png 2400w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_03-e1786327969567-300x226.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_03-e1786327969567-1024x771.png 1024w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_03-e1786327969567-768x579.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_03-e1786327969567-1536x1157.png 1536w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_03-e1786327969567-2048x1543.png 2048w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_03-e1786327969567-555x418.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_03-e1786327969567-1110x836.png 1110w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_03-e1786327969567-600x452.png 600w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_03-e1786327969567-1200x904.png 1200w" sizes="(max-width: 769px) 100vw, 769px" /></p>
<p><strong>5. Ferramentas e métodos de diagnóstico em campo</strong><br />
Os PHYs 10BASE-T1L de última geração expõem registradores e funções de diagnóstico acessíveis via MDIO / SPI ou através de protocolos de gerenciamento (PROFINET, EtherNet/IP, OPC UA). Ferramentas e métodos típicos incluem:<br />
•  Monitoramento contínuo de SNR/MSE/SQI — disponível com link ativo; ideal para tendências e alarmes de manutenção preditiva.<br />
•   TDR on-chip — execução sob demanda, conforme os recursos do PHY; permite estimar a localização de circuitos abertos, curtos e outras descontinuidades, com resolução e precisão dependentes do componente, do cabo e das condições do teste.<br />
•  Contadores de erro de frame e de símbolo — base para estimativa de BER em operação.<br />
•  Medição de resistência de loop e corrente/tensão de porta — integrada em switches e dispositivos com alimentação.<br />
•  Modos de teste PMA (Test Mode 1, 2, 3) — para validação de conformidade em laboratório (jitter, droop, PSD, return loss).<br />
•  Analisadores de rede / TAPs / mirror ports — para diagnóstico de camadas superiores e captura de tráfego.</p>
<p><strong>5.1 Fluxograma de Troubleshooting<br />
</strong>Em comissionamento, recomenda-se a sequência: (1) verificar continuidade e resistência de loop; (2) executar TDR em cada segmento; (3) estabelecer link e registrar SNR baseline; (4) aplicar carga de tráfego e confirmar BER/contador de erros próximos de zero; (5) documentar valores para comparação futura. Sem baseline, a detecção de tendência fica impossível.</p>
<p>A figura 7 apresenta um fluxo sistemático para diagnóstico da camada física de uma rede Ethernet-APL, partindo de um sintoma observado — link indisponível ou BER/SNR inadequados — e avançando por verificações elétricas e de qualidade do sinal até chegar à causa raiz e à ação corretiva. A lógica é importante porque evita substituir instrumentos, switches ou cabos sem antes determinar onde está efetivamente a degradação.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-13163" src="https://www.profibus.org.br/wp-content/uploads/2026/08/7.png" alt="" width="642" height="584" srcset="https://www.profibus.org.br/wp-content/uploads/2026/08/7.png 1027w, https://www.profibus.org.br/wp-content/uploads/2026/08/7-300x273.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/08/7-1024x931.png 1024w, https://www.profibus.org.br/wp-content/uploads/2026/08/7-768x698.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/08/7-555x505.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/08/7-600x546.png 600w" sizes="(max-width: 642px) 100vw, 642px" /></p>
<p style="text-align: center;"><em>Figura 7 – Fluxograma sugerido de diagnóstico de camada física em Ethernet-APL.</em></p>
<p><strong>5.1.1 Sintoma: Link down ou BER/SNR ruim</strong><br />
O diagnóstico começa quando há uma condição anormal. Ela pode ser evidente, como Link Down, ou uma degradação ainda sem perda de comunicação, percebida por redução do SNR, aumento da BER ou incremento dos contadores de erros.</p>
<p>É importante distinguir esses dois cenários. No Link Down, deve-se primeiro procurar problemas básicos de alimentação, continuidade e conexão. Quando o link permanece ativo, mas sua qualidade piora, a análise deve concentrar-se nas margens do canal e na evolução das métricas em relação ao estado de referência.</p>
<p><strong>5.1.2 Verificar alimentação e status da porta</strong><br />
Antes de analisar a integridade do sinal Ethernet, deve-se confirmar que o dispositivo está corretamente alimentado e que a porta do field switch está operacional.</p>
<p>Devem ser verificados tensão e corrente da porta, estado do PSE, presença de sobrecorrente ou proteção ativa, status do PHY e eventos de Link Up/Link Down. Uma queda excessiva de tensão, por exemplo, pode provocar reinicializações do instrumento e aparentar ser uma falha de comunicação.</p>
<p>Essa etapa separa rapidamente um problema de alimentação de um problema propriamente relacionado à transmissão 10BASE-T1L.</p>
<p><strong>5.1.3 Medir resistência de loop</strong><br />
A resistência de loop corresponde à resistência CC do caminho formado pelos dois condutores do par. Mais importante que avaliar apenas um valor absoluto é compará-lo com o baseline obtido durante o comissionamento.</p>
<p>Um aumento em relação ao histórico pode indicar oxidação, contato inadequado, terminal frouxo, degradação de conector ou cabo, além de contribuir para maior queda de tensão.</p>
<p>Por isso, a indicação lateral “Loop R alto? Contato/corrosion” representa uma primeira correlação entre uma grandeza elétrica e uma possível causa física.</p>
<p><strong>5.1.4 Executar TDR</strong><br />
Quando a condição do link e do equipamento permitir o teste, o TDR é utilizado para identificar descontinuidades de impedância ao longo do cabo.</p>
<p>O objetivo não é apenas dizer que o cabo está defeituoso, mas determinar aproximadamente onde está a anomalia. Uma reflexão pode estar associada a circuito aberto, curto-circuito, conector, emenda ou outra alteração de impedância. A distância estimada pelo TDR permite direcionar a inspeção física para uma região específica da instalação.</p>
<p>Assim, o TDR responde principalmente à pergunta: “Existe uma descontinuidade no meio físico e onde ela está?”</p>
<p><strong>5.1.5 Estabelecer o link e avaliar SNR / MSE / SQI</strong><br />
Com alimentação e integridade básica do meio verificadas, estabelece-se o link e passa-se à avaliação da qualidade efetiva da comunicação.</p>
<p>O SNR indica a margem entre o sinal útil e ruído/interferências. O MSE representa o erro residual observado no processo de recepção/equalização, enquanto o SQI fornece, quando disponibilizado pelo PHY, uma indicação consolidada da qualidade do sinal.</p>
<p>Essas métricas devem ser analisadas em conjunto e, principalmente, comparadas com o baseline daquela porta. Um SNR que permanece funcional, mas caiu significativamente em relação ao valor registrado no comissionamento, pode revelar uma degradação antes que ocorra a perda do link.</p>
<p>O valor 20,5 dB mostrado na lateral da figura deve ser entendido no contexto dos critérios adotados no artigo/PHY considerado, e não como um limite universal aplicável a qualquer implementação Ethernet-APL.</p>
<p><strong>5.1.6 Aplicar tráfego e monitorar contadores</strong><br />
Um link aparentemente saudável em condição estática pode apresentar problemas quando submetido à comunicação normal da planta. Por isso, a etapa seguinte verifica o comportamento durante o tráfego.</p>
<p>Devem ser acompanhados os contadores de erros, eventos do PHY, erros de frame/símbolo e eventuais perdas ou restabelecimentos do link. O objetivo é identificar problemas intermitentes que não aparecem em uma medição instantânea.</p>
<p>Por exemplo, uma conexão marginal pode manter Link Up e apresentar SNR aceitável, mas produzir aumento intermitente dos contadores de erros quando ocorre interferência eletromagnética ou quando aumenta a atividade da rede.</p>
<p><strong>5.1.7 Comparar com o baseline</strong><br />
Esta é uma das etapas mais importantes do fluxograma.</p>
<p>O diagnóstico não deve se limitar a perguntar se uma variável está “dentro ou fora do limite”. Deve também responder: “Quanto essa porta mudou desde que a rede estava comprovadamente saudável?”</p>
<p>Devem ser comparados valores atuais de SNR, MSE/SQI, resistência de loop, resultados do TDR e contadores de erro com aqueles registrados no comissionamento.</p>
<p>Imagine uma porta que apresentava SNR de 25 dB e, depois de alguns anos, passa a operar em 21 dB. Mesmo que o link continue ativo, a redução de 4 dB em relação ao baseline é uma informação relevante para manutenção preditiva.</p>
<p><strong>5.1.8 Identificar causa raiz e executar ação corretiva</strong><br />
A última etapa reúne todas as evidências.</p>
<p>Um Loop R crescente + reflexão localizada no TDR + redução gradual de SNR, por exemplo, forma uma assinatura muito mais útil do que qualquer uma dessas medições isoladamente. Dependendo do conjunto de sintomas, a causa pode estar relacionada a conectores, terminações, cabo, blindagem, interferência eletromagnética, alimentação ou ao próprio dispositivo.</p>
<p>A ação corretiva deve então atuar sobre a causa identificada: reaperto ou substituição de conexão, reparo do cabo, correção de aterramento/blindagem, redução da fonte de EMI, correção da alimentação ou substituição do componente defeituoso.</p>
<p>A lógica completa<br />
A ideia central do fluxograma pode ser resumida pela cadeia:</p>
<p>Sintoma → Alimentação/porta → Integridade CC → Integridade do cabo → Qualidade do sinal → Comportamento sob tráfego → Comparação histórica → Causa raiz</p>
<p>Assim, o diagnóstico deixa de ser baseado em tentativa e erro e passa a utilizar evidências correlacionadas. Em Ethernet-APL, isso é especialmente útil porque uma degradação física pode começar pequena — como oxidação de contato, alteração de impedância ou aumento de interferência — e inicialmente aparecer apenas como redução da margem do link, evoluindo posteriormente para erros e, finalmente, perda da comunicação.</p>
<p><strong>6. Exemplos ilustrativos de diagnóstico</strong><br />
Os casos a seguir são exemplos ilustrativos construídos para demonstrar a correlação entre sintomas, métricas e possíveis causas físicas. Os valores numéricos devem ser entendidos como exemplos de diagnóstico, e não como limites universais do Ethernet-APL.</p>
<p><strong>6.1 Caso 1 – Conector oxidado em Área Classificada</strong><br />
Sintoma: Link intermitente; SNR oscilando entre 18 e 22 dB; aumento intermitente dos contadores de erros de CRC. Investigação: TDR mostra pequeno pico de reflexão a 87 m; resistência de loop 10 % acima do valor de comissionamento.</p>
<p>Causa raiz: Conector M12 com oxidação por umidade e vibração.</p>
<p>Ação: Substituição do conector e reaperto com torque especificado; SNR estabilizou em 24 dB e erros desapareceram.</p>
<p><strong>6.2 Caso 2 – Cabo com dano de blindagem</strong><br />
Sintoma: SNR bom em laboratório, mas degrada para 19 dB quando motores de grande porte estão ligados.</p>
<p>Investigação: Medição de TCL fora de especificação; inspeção visual revela corte na blindagem próximo a uma passagem de cabo.</p>
<p>Causa raiz: Conversão de modo comum (EMI dos motores) para diferencial devido ao dano de shield. Ação: Reparo da blindagem + melhoria do aterramento; SNR recuperado sob carga.</p>
<p><strong>6.3 Caso 3 – Comprimento no limite + envelhecimento</strong><br />
Sintoma: SNR lentamente caindo de 22 dB (comissionamento) para 20,2 dB após 1 ano; BER residual detectável sob tráfego intenso.</p>
<p>Investigação: Insertion Loss estimado maior; Loop R aumentou 8 %.</p>
<p>Causa raiz: Envelhecimento do dielétrico e leve corrosão em terminais de campo.</p>
<p>Ação: Planejamento de substituição do segmento no próximo turnaround; monitoramento intensificado até lá.</p>
<p><strong>6.4 Caso 4 – Micro-interrupções por vibração</strong><br />
Sintoma: Oscilações aleatórias do link com duração de recuperação entre 400 ms e 3 s; sem defeito permanente detectável por TDR ou Loop R.</p>
<p>Investigação: Correlação temporal com vibração de equipamento rotativo próximo; teste de interrupção controlada confirma sensibilidade a gaps &gt; 750 µs.</p>
<p>Causa raiz: Contato por pressão (spring contact) inadequado para o ambiente vibratório.</p>
<p>Ação: Substituição por conector com travamento mecânico positivo (IEC 63171 série) ou terminal parafuso; oscilações do link eliminadas.</p>
<p><strong>7. Recomendações de boas-práticas</strong><br />
1.   Baseline no comissionamento: registre SNR, Loop R, comprimento TDR e contadores de erro para cada porta. Sem um baseline, torna-se difícil identificar tendências de degradação.<br />
2.   Alarmes de SNR: configure níveis de alerta com base nas recomendações do fabricante do PHY e, preferencialmente, na variação em relação ao baseline obtido durante o comissionamento. Integre esses alarmes ao sistema de manutenção (CMMS / asset management) e, quando aplicável, ao modelo de diagnóstico NE 107.<br />
3.   TDR periódico: em segmentos críticos, execute TDR anualmente ou após intervenções mecânicas no cabo.<br />
4.    Qualidade de conectores: prefira conectores especificados para SPE/APL (IEC 63171-2 / 63171-6) e torques de aperto controlados; evite contatos por pressão simples em ambientes vibratórios.<br />
5.    Cabo especificado: utilize cabos adequados ao Ethernet-APL e que atendam aos requisitos aplicáveis de Insertion Loss, Return Loss, Coupling Attenuation, balanceamento e às condições ambientais da instalação.<br />
6.   Documentação de topologia: mantenha mapa atualizado de comprimentos e classes de potência para facilitar o isolamento de falhas.<br />
7.    Treinamento: capacite a equipe de manutenção para interpretar SNR, TDR e contadores de erro, evitando substituições desnecessárias de dispositivos.</p>
<p><strong>8. Checklist de comissionamento — Ethernet-APL (10BASE-T1L)</strong><br />
Segue um checklist prático e resumido, seguindo a sequência lógica do fluxograma de troubleshooting.</p>
<p><strong>8.1 Pré-comissionamento — documentação e topologia</strong><br />
&#8211; Mapa de topologia atualizado (trunk + spur) com comprimentos e classes de potência;<br />
&#8211; Cabos especificados para Ethernet-APL (Insertion Loss, Return Loss, Coupling Attenuation e balanceamento dentro dos requisitos);<br />
&#8211; Conectores conforme IEC 63171-2 / 63171-6 (evitar contatos por pressão simples em ambientes vibratórios);<br />
&#8211; Perfis de porta definidos (Trunk 2,4 Vpp / Spur 1,0 Vpp) e classes de potência (A/B/C para spur, 3/4 para trunk);<br />
&#8211; Orçamento de potência validado (PoDL / SPoE).</p>
<p><strong>8.2 Verificação de continuidade e resistência de loop</strong><br />
&#8211; Medir resistência de loop (ida e volta do par) e registrar como baseline;<br />
&#8211; Comparar com o valor esperado para o comprimento e seção do condutor;<br />
&#8211; Verificar continuidade dos condutores (sem aberto ou curto);<br />
&#8211; Verificar integridade da blindagem (shield) e aterramento.</p>
<p><strong>8.3 Reflectometria no Domínio do Tempo (TDR)</strong><br />
&#8211; Executar TDR em cada segmento (trunk e spur)<br />
&#8211; Registrar assinatura de reflexão como baseline<br />
&#8211; Verificar ausência de:<br />
Picos positivos (circuito aberto ou aumento de impedância);<br />
Picos negativos (curto-circuito ou redução de impedância);<br />
Múltiplas reflexões pequenas (emendas, conectores intermediários);<br />
&#8211; Se houver reflexões, estimar a distância:</p>
<p><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-13168" src="https://www.profibus.org.br/wp-content/uploads/2026/08/f5.jpg" alt="" width="92" height="51" /></p>
<p><strong>8.4 Estabelecimento do link e qualidade do sinal</strong><br />
&#8211; Estabelecer link e verificar status da porta (Link Up);<br />
&#8211; Medir SNR e registrar como baseline;<br />
&#8211; Medir MSE / SQI e registrar baseline;<br />
&#8211; Verificar classificação do SNR:<br />
&gt; 20,5 dB → boa margem ✅<br />
19,5 – 20,5 dB → zona de transição, monitorar ⚠️<br />
&lt; 19,5 dB → margem insuficiente, investigar ❌<br />
&#8211; Verificar Return Loss (deve atender aos limites APL, que são +6 dB mais rigorosos que IEEE 802.3cg);<br />
&#8211; Verificar TCL e ELTCTL (balanceamento do par).</p>
<p><strong>8.5 Teste sob tráfego</strong><br />
&#8211; Aplicar carga de tráfego normal da planta;<br />
&#8211; Monitorar contadores de erro (CRC, erros de símbolo, erros de frame);<br />
&#8211; Verificar BER estimada conforme os critérios aplicáveis do PHY e do canal;<br />
&#8211; Confirmar que não há perdas ou oscilações de link;<br />
&#8211; Testar com fontes de EMI ativas (inversores, motores, soldas) para verificar degradação de SNR.</p>
<p><strong>8.6 Documentação do baseline</strong><br />
Registrar para cada porta:</p>
<p style="text-align: center;"><img loading="lazy" decoding="async" class="aligncenter wp-image-13135 " src="https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_04-e1786328258246.png" alt="" width="717" height="221" srcset="https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_04-e1786328258246.png 2400w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_04-e1786328258246-300x93.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_04-e1786328258246-1024x316.png 1024w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_04-e1786328258246-768x237.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_04-e1786328258246-1536x474.png 1536w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_04-e1786328258246-2048x631.png 2048w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_04-e1786328258246-555x171.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_04-e1786328258246-1110x342.png 1110w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_04-e1786328258246-600x185.png 600w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela_04-e1786328258246-1200x370.png 1200w" sizes="(max-width: 717px) 100vw, 717px" /><em>Tabela 4 – Documentação do Baseline por porta</em></p>
<p><strong>8.7 Configuração de alarmes e manutenção preditiva</strong><br />
&#8211; Configurar alarmes de SNR com base no baseline (ex.: alerta se SNR cair X dB abaixo do valor de comissionamento);<br />
&#8211; Integrar alarmes ao CMMS / sistema de asset management;<br />
&#8211; Mapear SQI/MSE para indicadores NAMUR NE 107 (Good / Maintenance Required / Out of Spec / Failure);<br />
&#8211; Programar TDR periódico (anual ou após intervenções mecânicas no cabo).</p>
<p><strong>9. Confiabilidade, arquitetura e resiliência operacional</strong><br />
O diagnóstico da camada física permite reconhecer a degradação de um enlace e localizar causas prováveis. Entretanto, a disponibilidade de uma instalação Ethernet-APL também depende de como esses enlaces são organizados na arquitetura. A conexão ponto a ponto entre instrumento e Field Switch melhora o isolamento de falhas no nível do instrumento e do spur, enquanto Field Switches, fontes, uplinks e elementos de agregação permanecem compartilhados. Por isso, confiabilidade deve ser analisada simultaneamente nos níveis físico e arquitetural.</p>
<p><strong>9.1 Ethernet-APL muda o domínio das falhas</strong><br />
O domínio de falha representa quantos elementos ou funções do processo podem ser afetados pela falha de determinado componente. Falhas do instrumento, spur ou porta individual tendem a afetar um único dispositivo. Já falhas do Field Switch, alimentação ou uplink podem afetar vários instrumentos simultaneamente. Em níveis superiores, uma falha de agregação pode atingir vários Field Switches. A vantagem do APL está no forte isolamento das falhas locais; o desafio está em projetar adequadamente os elementos compartilhados.</p>
<p><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-13131" src="https://www.profibus.org.br/wp-content/uploads/2026/08/tabela-05.png" alt="" width="734" height="199" srcset="https://www.profibus.org.br/wp-content/uploads/2026/08/tabela-05.png 734w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela-05-300x81.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela-05-555x150.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/08/tabela-05-600x163.png 600w" sizes="(max-width: 734px) 100vw, 734px" /></p>
<p style="text-align: center;"><em>Tabela 5 – Domínios de falha em uma arquitetura Ethernet-APL</em></p>
<p style="text-align: left;"><strong>9.2 MTBF não é suficiente para avaliar a confiabilidade da planta</strong><br />
Comparar arquiteturas apenas pelo MTBF – Mean Time Between Failures – é insuficiente. Um componente pode falhar raramente e, ainda assim, produzir grande impacto quando falha. A disponibilidade pode ser expressa de forma simplificada por A = MTBF / (MTBF + MTTR), onde MTTR é o tempo médio para restauração. A análise deve considerar MTBF, MTTR, cobertura de diagnóstico, redundância, domínio de falha e consequência para o processo.</p>
<p><strong>9.3 Mais Field Switches podem significar maior disponibilidade</strong><br />
Mais componentes podem aumentar a probabilidade de que algum deles apresente uma falha, mas isso não significa necessariamente menor disponibilidade da planta. Um único switch para 16 instrumentos concentra a consequência; dois switches com oito instrumentos cada reduzem o domínio de cada falha. A decisão deve considerar Risco ≈ Probabilidade × Consequência. O objetivo não é simplesmente minimizar o número de switches, mas limitar o impacto de cada evento.</p>
<p><strong>9.4 Não basta dividir instrumentos numericamente</strong><br />
A segmentação deve considerar a função de processo. Colocar todos os instrumentos essenciais a uma mesma função crítica no mesmo Field Switch pode criar um domínio de falha funcional. A filosofia deve evitar que uma única falha elimine simultaneamente medição, controle e informação operacional essenciais. Portanto, deve-se segmentar também por consequência da falha.</p>
<p><strong>9.5 Pontos únicos de falha</strong><br />
Para cada elemento da cadeia Instrumento → Field Switch → uplink → agregação → controlador, deve-se perguntar: se este componente falhar, qual será a consequência? Field Switches, fontes e switches de agregação podem constituir Pontos únicos de falha. Redundância, segregação física, alimentação independente e caminhos alternativos devem ser aplicados quando a análise de risco justificar.</p>
<p><strong>9.6 A confiabilidade começa antes da falha</strong><br />
Ethernet-APL pode disponibilizar Link Up/Down, SNR, MSE, SQI, contadores de erro, tensão/corrente de porta, eventos do PHY e, dependendo do hardware, TDR e outros diagnósticos do cabo. Isso permite migrar de “falhou → investigar” para “está degradando → investigar antes da falha”. O baseline de comissionamento é fundamental para detectar tendências.</p>
<p><strong>9.7 Diagnóstico físico e arquitetural são complementares</strong><br />
O diagnóstico físico responde por que um instrumento apresenta problemas e pode correlacionar conector, reflexão, SNR, erros, TDR e Loop R. O diagnóstico arquitetural responde por que vários instrumentos ficaram indisponíveis simultaneamente. Quando vários dispositivos do mesmo Field Switch desaparecem ao mesmo tempo, a investigação deve priorizar os elementos compartilhados.</p>
<p><strong>9.8 Alarmes sem correlação podem criar confusão</strong><br />
Uma falha de uplink pode gerar vários alarmes de comunicação e parecer uma falha simultânea de instrumentos. Uma infraestrutura inteligente deve apresentar a causa comum — por exemplo, “FS-03 – UPLINK DOWN” — e os dispositivos afetados como consequências. A correlação de alarmes reduz o MTTR e direciona o troubleshooting.</p>
<p><strong>9.9 Confiabilidade técnica e confiança operacional</strong><br />
A confiança dos operadores não aparece nos cálculos de MTBF. Se um Field Switch falha e vários instrumentos “desaparecem”, a percepção da equipe dependerá da rapidez com que a causa é identificada e a operação recuperada. A confiança na tecnologia é construída principalmente durante as falhas. Projeto, procedimentos e treinamento devem ser tratados conjuntamente.</p>
<p><strong>9.10 O operador precisa reconhecer padrões de falha</strong><br />
Um instrumento offline direciona a investigação para instrumento, spur, conector e porta. Vários instrumentos do mesmo Field Switch offline direcionam para switch, alimentação e uplink. Dispositivos de vários switches indisponíveis sugerem investigar agregação, rede superior, alimentação compartilhada ou controlador. Esses padrões devem fazer parte do treinamento.</p>
<p><strong>9.11 MTTR pode ser tão importante quanto MTBF</strong><br />
Uma falha rara, mas que exige horas para localização, pode ter impacto maior que uma falha rapidamente diagnosticada. Registros temporais, diagnósticos precisos e correlação de causas comuns permitem reduzir o MTTR. O projeto deve buscar simultaneamente alta confiabilidade e rápida recuperação.</p>
<p><strong>9.12 Redundância deve ser baseada em risco</strong><br />
Nem todo Field Switch precisa necessariamente ser redundante. A pergunta correta é qual a consequência da falha daquele switch. Para funções cuja perda simultânea comprometa produção, qualidade ou disponibilidade, deve-se avaliar redundância, segregação, alimentação independente, caminhos alternativos e estratégias de recuperação. Funções de segurança exigem análise específica.</p>
<p><strong>9.13 O retorno ao 4–20 mA não deve ser automático</strong><br />
Sistemas convencionais também possuem elementos compartilhados: cartões de I/O, fontes, racks, backplanes, controladores e redes. A comparação deve considerar a arquitetura completa. Manter instrumentos críticos fora da infraestrutura digital também pode significar abrir mão de informações de diagnóstico valiosas para manutenção preditiva.</p>
<p><strong>9.14 Uma filosofia de projeto para Ethernet-APL confiável</strong><br />
Uma estratégia pode seguir seis etapas: definir criticidade dos loops; mapear domínios de falha; identificar Pontos únicos de falha; aplicar segmentação e redundância onde justificadas; projetar diagnóstico e correlação de alarmes; criar baseline, procedimentos e treinamento. O objetivo é fazer com que falhas locais permaneçam locais e falhas comuns sejam rapidamente identificadas.</p>
<p><strong>9.15 Da confiabilidade do componente à resiliência do sistema</strong><br />
Um componente confiável falha pouco. Um sistema resiliente continua desempenhando suas funções essenciais ou se recupera rapidamente quando ocorre uma falha. Uma arquitetura resiliente combina componentes confiáveis, isolamento de falhas, redundância adequada, diagnóstico, recuperação rápida e procedimentos operacionais.</p>
<p><strong>10. Conclusão</strong><br />
A confiabilidade de uma instalação Ethernet-APL deve ser tratada em duas dimensões complementares. A primeira é a integridade do enlace 10BASE-T1L, avaliada por métricas como BER, SNR, MSE/SQI, Return Loss, TCL/ELTCTL, jitter, TDR e resistência de loop. A segunda é a resiliência da arquitetura, que determina quantos instrumentos podem ser afetados por uma falha de Field Switch, alimentação, uplink ou agregação e quão rapidamente a operação pode ser restaurada.</p>
<p>O baseline de comissionamento conecta essas duas dimensões: permite reconhecer a degradação física antes da perda do link e fornece dados objetivos para reduzir o MTTR. Ao mesmo tempo, segmentação por criticidade, identificação e mitigação de Single Points of Failure, correlação de alarmes e treinamento operacional limitam as consequências das falhas que inevitavelmente ocorrerão ao longo do ciclo de vida da planta.</p>
<p>Assim, uma estratégia madura de Ethernet-APL não pergunta apenas se o link está ativo. Ela procura saber qual é sua margem, como essa margem está evoluindo, onde está a anomalia, qual é o domínio de falha do componente envolvido e qual será o impacto no processo. Diagnóstico físico, arquitetura e operação passam a formar um único sistema de gestão da confiabilidade.</p>
<p>Uma rede tecnicamente funcional torna-se realmente confiável quando falhas locais permanecem locais, falhas comuns são rapidamente reconhecidas, o impacto sobre o processo é controlado e a equipe de operação dispõe de informação suficiente para agir com segurança e rapidez.</p>
<p><strong>11. Referências</strong><br />
1.     IEEE Std 802.3-2022 – IEEE Standard for Ethernet (Clause 146 – 10BASE-T1L; Clause 98 – Auto-Negotiation).<br />
2.     IEC TS 63444:2023 – Industrial networks – Ethernet-APL port profile specification.<br />
3.    FieldComm Group / ODVA / OPC Foundation / PI – Ethernet-APL Engineering Guideline (v1.0 e posteriores).<br />
4.    Analog Devices AN-2553 – ADIN1100/ADIN1110/ADIN2111 Link and Cable Diagnostics.<br />
5.    Texas Instruments SNLA364 – DP83TD510E Cable Diagnostics Application Note.<br />
6.    NAMUR Recommendation NE 123 – Service and maintenance of the physical layer of fieldbuses.<br />
7.    NAMUR Recommendation NE 107 – Self-Monitoring and Diagnosis of Field Devices.<br />
8.    Telebyte / FieldComm Group – Ethernet-APL Data Test Specification e Method of Implementation.<br />
9.    ISO/IEC 11801-3 e especificações de cabo T1-A-1000 / SP1-1000 (referência de canal).<br />
10. Ethernet-APL Engineering Guideline.<br />
11. Artigos Técnicos César Cassiolato</p>
<p>&nbsp;</p>
<p><em><strong>(*) César Cassiolato, </strong>CEO da Vivace Process Instruments LTDA.</em></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.profibus.org.br/noticia/ethernet-apl-diagnostico-avancado-da-camada-fisica-confiabilidade/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">13156</post-id>	</item>
		<item>
		<title>Ethernet-APL: o meio físico que está transformando a instrumentação – instalação e boas práticas</title>
		<link>https://www.profibus.org.br/noticia/ethernet-apl-o-meio-fisico-que-esta-transformando-a-instrumentacao-instalacao-e-boas-praticas/</link>
					<comments>https://www.profibus.org.br/noticia/ethernet-apl-o-meio-fisico-que-esta-transformando-a-instrumentacao-instalacao-e-boas-praticas/#respond</comments>
		
		<dc:creator><![CDATA[Marketing]]></dc:creator>
		<pubDate>Tue, 07 Jul 2026 00:58:17 +0000</pubDate>
				<category><![CDATA[Artigo técnico]]></category>
		<guid isPermaLink="false">https://www.profibus.org.br/?p=13061</guid>

					<description><![CDATA[César Cassiolato (*) 1. Introdução e contexto A evolução da automação de processos industriais exige cada vez mais largura de banda, integração nativa com sistemas corporativos (TI/OT) e capacidades avançadas de diagnóstico e manutenção preditiva. O Ethernet-APL (Advanced Physical Layer) surge como a solução padronizada para levar Ethernet de alta velocidade diretamente aos instrumentos de [&#8230;]]]></description>
										<content:encoded><![CDATA[<p style="text-align: right;"><em><strong>César Cassiolato (*) </strong></em></p>
<p><strong>1. Introdução e contexto<br />
</strong>A evolução da automação de processos industriais exige cada vez mais largura de banda, integração nativa com sistemas corporativos (TI/OT) e capacidades avançadas de diagnóstico e manutenção preditiva.</p>
<p>O Ethernet-APL (Advanced Physical Layer) surge como a solução padronizada para levar Ethernet de alta velocidade diretamente aos instrumentos de campo em áreas classificadas. Ele combina a robustez e a segurança intrínseca dos fieldbuses tradicionais com a velocidade e a universalidade do Ethernet (10 Mbit/s full-duplex sobre apenas dois fios).</p>
<p>Este artigo foca especificamente no <strong>sinal APL</strong>, o sinal elétrico que trafega na camada física, detalhando suas características, diferenças entre tronco (trunk) e ramal (spur), implicações práticas para projetos de instrumentação e apresentando formas de onda ilustrativas do meio físico para facilitar a compreensão técnica.</p>
<p><strong>2. O que é o Sinal APL e o Ethernet-APL</strong><br />
O sinal APL é o sinal elétrico de camada física definido pelo padrão Ethernet-APL. Ele é baseado no PHY 10BASE-T1L do IEEE 802.3cg-2019 (Single Pair Ethernet), com extensões específicas para aplicações em automação de processos:</p>
<ul>
<li>Transmissão full-duplex a 10 Mbit/s sobre um único par trançado balanceado</li>
<li>Fornecimento simultâneo de potência e dados (Power over Data Line — PoDL)</li>
<li>Suporte nativo a segurança intrínseca segundo IEC TS 60079-47 (2-WISE)</li>
<li>Topologia trunk-and-spur otimizada para plantas de processo</li>
<li>Compatibilidade com cabos de fieldbus existentes (Type A IEC 61158-2)</li>
<li>Port profiles padronizados que definem características elétricas e de potência de cada porta</li>
</ul>
<p>Diferentemente do Ethernet industrial convencional (100BASE-TX/1000BASE-T), o sinal APL foi projetado para operar em ambientes hostis, longas distâncias e com restrições rigorosas de energia em áreas explosivas. A taxa de 10 Mbit/s representa um avanço de aproximadamente <strong>300 vezes</strong> em relação à taxa de 31,25 kbit/s dos fieldbuses clássicos de processo.</p>
<p><img loading="lazy" decoding="async" class="aligncenter  wp-image-13062" src="https://www.profibus.org.br/wp-content/uploads/2026/07/F-1.png" alt="" width="670" height="448" srcset="https://www.profibus.org.br/wp-content/uploads/2026/07/F-1.png 910w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-1-300x200.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-1-768x513.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-1-555x371.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-1-600x401.png 600w" sizes="(max-width: 670px) 100vw, 670px" /></p>
<p style="text-align: center;"><em>Figura 1 &#8211; Comparando o Ethernet-APL x outros protocolos em relação a velocidade de comunicação</em></p>
<p><strong>3. Arquitetura do PHY Ethernet-APL</strong><br />
O PHY Ethernet-APL implementa o padrão 10BASE-T1L com extensões específicas para automação de processos. A arquitetura interna inclui:</p>
<p style="text-align: center;"><img loading="lazy" decoding="async" class="aligncenter  wp-image-13064" src="https://www.profibus.org.br/wp-content/uploads/2026/07/F-2.jpg" alt="" width="606" height="407" srcset="https://www.profibus.org.br/wp-content/uploads/2026/07/F-2.jpg 1168w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-2-300x201.jpg 300w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-2-1024x687.jpg 1024w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-2-768x516.jpg 768w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-2-555x373.jpg 555w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-2-1110x745.jpg 1110w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-2-600x403.jpg 600w" sizes="(max-width: 606px) 100vw, 606px" /></p>
<p style="text-align: center;"><em>Figura 2 &#8211; Arquitetura de blocos do PHY Ethernet-APL (10BASE-T1L). Destaque para o bloco PMA com Echo Canceller, Equalizer e PAM-3 Modulator, além da injeção de potência (PoDL) diferenciada para Trunk e Spur.</em></p>
<p>Componentes-chave: MAC Interface, Physical Coding Sublayer (PCS), Physical Medium Attachment (PMA) com Scrambler, Encoder, PAM-3 Modulator, Echo Canceller, Equalizer e Line Driver. A separação lógica entre Trunk e Spur permite otimizar potência e segurança conforme a localização na planta.</p>
<p><strong>4. Características Técnicas do Sinal Físico<br />
</strong><strong>4.1 Taxa de Transmissão e Modulação PAM-3<br />
</strong>O sinal APL opera a <strong>10 Mbit/s full-duplex</strong>. A modulação utilizada é <strong>PAM-3</strong> (Pulse Amplitude Modulation com 3 níveis). Essa escolha permite boa imunidade a ruído, equalização eficiente e cancelamento de eco necessário para operação full-duplex em um único par. O sinal é transmitido de forma <strong>diferencial</strong> entre os dois condutores do par (APL Signal + e APL Signal −), conferindo excelente imunidade a ruídos de modo comum, fundamental em ambientes industriais com altas interferências eletromagnéticas. A modulação PAM‑3 utiliza três níveis de tensão (+1, 0 e −1), aumentando a eficiência espectral e reduzindo a largura de banda necessária.</p>
<p>A operação full-duplex em um único par é possível graças a técnicas avançadas implementadas no PHY: cancelamento de eco adaptativo, equalização de canal e codificação específica que mantém o sinal DC-balanceado.</p>
<p><strong>4.2 Modulação Pam-3 E Codificação 4B3T</strong><br />
O Ethernet-APL utiliza a modulação PAM-3 combinada com técnicas de codificação ternária (4B3T) para entregar uma solução de camada física robusta, eficiente e adequada para automação de processos. Essa escolha técnica permite atingir 10 Mbit/s full-duplex em um único par trançado, com excelente imunidade a ruído e capacidade de operar em distâncias de até 1.000 metros no tronco, algo que seria muito mais difícil ou impossível com modulações binárias tradicionais.</p>
<p>PAM-3 significa <strong>Pulse Amplitude Modulation com 3 níveis</strong> (Modulação por Amplitude de Pulso com 3 níveis).</p>
<p>Diferente da modulação binária tradicional (PAM-2 ou NRZ), que usa apenas dois níveis de tensão (ex: 0V e +V), o PAM-3 utiliza <strong>três níveis distintos de amplitude</strong> para representar os dados.</p>
<p>No Ethernet-APL, os três níveis são tipicamente representados como:</p>
<ul>
<li>+1 → Tensão positiva (ex: +1,2 V no Trunk)</li>
<li>0  → Tensão zero</li>
<li>-1 → Tensão negativa (ex: -1,2 V no Trunk)</li>
</ul>
<p style="text-align: left;"><strong>4.2.1 Por que usar PAM-3 no Ethernet-APL?<br />
</strong>A escolha do PAM-3 traz várias vantagens importantes para aplicações de automação de processos:</p>
<table class=" aligncenter" style="height: 459px;" width="644">
<tbody>
<tr>
<td width="187"><strong>Característica</strong></td>
<td width="228">
<p style="text-align: left;"><strong>PAM-2 (NRZ)</strong></p>
</td>
<td width="228"><strong>PAM-3 (APL)</strong></td>
</tr>
<tr>
<td width="187"><strong>Níveis de tensão</strong></td>
<td width="228">2 níveis</td>
<td width="228">3 níveis</td>
</tr>
<tr>
<td width="187"><strong>Eficiência espectral</strong></td>
<td width="228">Menor</td>
<td width="228">Maior</td>
</tr>
<tr>
<td width="187"><strong>Imunidade a ruído</strong></td>
<td width="228">Boa</td>
<td width="228">Superior</td>
</tr>
<tr>
<td width="187"><strong>Cancelamento de eco</strong></td>
<td width="228">Mais difícil</td>
<td width="228">Mais fácil</td>
</tr>
<tr>
<td width="187"><strong>Full-duplex em 1 par</strong></td>
<td width="228">Limitado</td>
<td width="228">Viável</td>
</tr>
<tr>
<td width="187"><strong>Largura de banda necessária</strong></td>
<td width="228">Maior</td>
<td width="228">Menor</td>
</tr>
</tbody>
</table>
<p style="text-align: center;"><em>Tabela 1 &#8211; Comparação entre PAM-2 e PAM-3 no contexto do Ethernet-APL.</em></p>
<p><strong>4.2.2 O que é e como funciona 4B3T?</strong><br />
4B3T significa <strong>4 Binary bits para 3 Ternary symbols</strong> (4 bits binários mapeados em 3 símbolos ternários).</p>
<p>É um <strong>esquema de codificação de linha</strong> (line coding), não a modulação propriamente dita. Sua função é converter grupos de bits binários em símbolos que usam os três níveis do PAM-3 de forma eficiente.</p>
<p>Em sistemas binários tradicionais, cada bit é representado por um símbolo. No 4B3T, o sistema agrupa <strong>4 bits binários</strong> e os converte em <strong>3 símbolos ternários</strong> (cada símbolo pode assumir os valores -1, 0 ou +1).</p>
<p>Essa conversão traz duas grandes vantagens:</p>
<ul>
<li>Redução da taxa de símbolo: 4 bits são transmitidos usando apenas 3 símbolos → maior eficiência espectral.</li>
<li>Melhor controle do espectro e balanço DC: A codificação é projetada para evitar longas sequências de símbolos iguais, reduzindo componentes de baixa frequência e melhorando a equalização.</li>
</ul>
<p style="text-align: center;"><img loading="lazy" decoding="async" class="aligncenter  wp-image-13065" src="https://www.profibus.org.br/wp-content/uploads/2026/07/F-3.png" alt="" width="710" height="473" srcset="https://www.profibus.org.br/wp-content/uploads/2026/07/F-3.png 1536w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-3-300x200.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-3-1024x683.png 1024w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-3-768x512.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-3-555x370.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-3-1110x740.png 1110w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-3-600x400.png 600w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-3-1200x800.png 1200w" sizes="(max-width: 710px) 100vw, 710px" /></p>
<p style="text-align: center;"><em>Figura 3 &#8211; PAM-3 x APL</em></p>
<p><strong>4.2.3 Relação entre PAM-3 e 4B3T no Ethernet-APL<br />
</strong>No padrão IEEE 802.3cg (10BASE-T1L), que serve de base para o Ethernet-APL, a camada física combina:</p>
<ul>
<li><strong>Modulação PAM-3</strong> → Define os três níveis de tensão do sinal físico.</li>
<li><strong>Codificação ternária (baseada em 4B3T)</strong> → Mapeia os bits de dados em sequências de símbolos ternários de forma eficiente e com bom balanço DC.</li>
<li><strong>Scrambling + Precodificação</strong> → Técnicas adicionais para randomizar o sinal e melhorar o desempenho do cancelamento de eco e da equalização.</li>
</ul>
<p>Embora o 10BASE-T1L não utilize exatamente o 4B3T clássico (como no antigo 100BASE-T4), ele emprega um mapeamento ternário muito similar, otimizado para operação full-duplex em longas distâncias e com forte ênfase em DC balance e redução de interferência eletromagnética.</p>
<p><strong>4.2.4 Benefícios Práticos no Contexto do APL<br />
</strong>A combinação de PAM-3 com codificação ternária traz benefícios diretos para aplicações industriais:</p>
<ul>
<li><strong>Operação full-duplex em um único par</strong> — essencial para reduzir cabeamento em plantas existentes.</li>
<li><strong>Maior imunidade a ruído industrial</strong> — fundamental em ambientes com VFDs, motores e fontes de interferência.</li>
<li><strong>Alcance de até 1.000 m no Trunk</strong> — com boa relação sinal/ruído mesmo em cabos longos.</li>
<li><strong>Menor consumo de energia e aquecimento</strong> — importante para dispositivos alimentados pelo próprio barramento.</li>
<li><strong>Melhor equalização e cancelamento de eco</strong> — permite que o PHY recupere o sinal mesmo em canais difíceis.</li>
</ul>
<p><strong>4.3 Níveis de Tensão: Trunk vs Spur — Diferença Crítica<br />
</strong>Uma das características mais importantes do padrão APL é a existência de <strong>dois modos de operação com amplitudes de sinal distintas</strong>:</p>
<table class=" aligncenter" width="643">
<tbody>
<tr>
<td width="147"><strong>Parâmetro</strong></td>
<td width="248"><strong>Trunk (Tronco)</strong></td>
<td width="248"><strong>Spur (Ramal)</strong></td>
</tr>
<tr>
<td width="147"><strong>Taxa de dados</strong></td>
<td width="248">10 Mbit/s full-duplex</td>
<td width="248">10 Mbit/s full-duplex</td>
</tr>
<tr>
<td width="147"><strong>Modulação</strong></td>
<td width="248">PAM-3 (3 níveis)</td>
<td width="248">PAM-3 (3 níveis)</td>
</tr>
<tr>
<td width="147"><strong>Amplitude do sinal</strong></td>
<td width="248">~2,4 Vpp (diferencial)</td>
<td width="248">~1,0 Vpp (diferencial)</td>
</tr>
<tr>
<td width="147"><strong>Distância máxima</strong></td>
<td width="248">até 1.000 m (Cat. IV)</td>
<td width="248">até 200 m (2-WISE)</td>
</tr>
<tr>
<td width="147"><strong>Potência típica</strong></td>
<td width="248">Alta (até ~57-92 W @ 50 V)</td>
<td width="248">Baixa — IS: Classe A 0,54 W / Classe C 1,1 W @ 15 V</td>
</tr>
<tr>
<td width="147"><strong>Finalidade principal</strong></td>
<td width="248">Power Switch ↔ Field Switches</td>
<td width="248">Field Switch → Dispositivo de campo</td>
</tr>
<tr>
<td width="147"><strong>Requisito de segurança</strong></td>
<td width="248">Ex ib / Ex ic (área classificada)</td>
<td width="248">Ex ia / Ex ib (Zona 0/1) — 2-WISE</td>
</tr>
</tbody>
</table>
<p style="text-align: center;"><em>Tabela 2 &#8211; Comparação dos parâmetros do sinal APL entre Trunk e Spur (fontes: Ethernet-APL Engineering Guideline, especificações de conformidade e IEEE 802.3cg-2019).</em></p>
<p><strong>Trunk (2,4 Vpp): </strong>Utilizado no segmento principal que conecta o Power Switch aos Field Switches. A maior amplitude proporciona melhor relação sinal/ruído em longas distâncias (até 1.000 m) e suporta maior número de dispositivos e maior potência agregada.</p>
<p><strong>Spur (1,0 Vpp): </strong>Utilizado nos ramais que conectam os Field Switches aos instrumentos de campo. A amplitude reduzida é essencial para limitar a energia disponível em áreas classificadas, permitindo certificação intrinsecamente segura (Ex ia/ic) conforme o conceito 2-WISE (IEC TS 60079-47).</p>
<p style="text-align: center;"><img loading="lazy" decoding="async" class="aligncenter  wp-image-13075" src="https://www.profibus.org.br/wp-content/uploads/2026/07/F-4.png" alt="" width="731" height="403" srcset="https://www.profibus.org.br/wp-content/uploads/2026/07/F-4.png 2141w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-4-300x165.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-4-1024x564.png 1024w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-4-768x423.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-4-1536x847.png 1536w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-4-2048x1129.png 2048w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-4-555x306.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-4-1110x612.png 1110w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-4-600x331.png 600w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-4-1200x661.png 1200w" sizes="(max-width: 731px) 100vw, 731px" /></p>
<p style="text-align: center;"><em>Figura 4 &#8211; Diagrama do meio físico Ethernet-APL: topologia Trunk-and-Spur, componentes da camada física (Power Switch, Field Switch) e características principais de sinal e potência.</em></p>
<p>No tronco utiliza-se aproximadamente 2,4 Vpp diferencial para maximizar o alcance; nos spurs utiliza-se cerca de 1,0 Vpp para atender aos requisitos de segurança intrínseca.</p>
<p>Já nos fieldbuses tradicionais, como o PROFIBUS-PA e o Foundation Fieldbus H1, a amplitude típica do sinal Manchester é significativamente menor (em torno de centenas de milivolts até cerca de 1 Vpp, dependendo do ponto de medição e da carga do barramento). Além disso, a taxa de transmissão é de apenas 31,25 kbit/s. Essa diferença faz com que o Ethernet-APL disponha de uma margem muito maior para compensar perdas do meio físico e recuperar o sinal através dos algoritmos implementados no PHY.</p>
<p><strong>4.3.1 A Maior Robustez do Sinal Ethernet-APL em Relação aos Fieldbuses Convencionais<br />
</strong>Uma das principais vantagens do Ethernet-APL em relação aos fieldbuses tradicionais não está apenas na velocidade de comunicação, mas também na robustez elétrica do seu sinal.</p>
<p>Embora o Ethernet-APL opere a uma taxa aproximadamente <strong>300 vezes superior</strong> à do PROFIBUS-PA ou Foundation Fieldbus H1, seu desempenho em ambientes industriais severos é notavelmente elevado. Isso é possível graças à combinação de maior amplitude de sinal (especialmente no Trunk), transmissão diferencial, processamento digital avançado e técnicas modernas de recuperação do sinal.</p>
<p><strong>4.3.1.1 Maior amplitude, maior margem contra ruídos<br />
</strong>No segmento <strong>Trunk</strong>, o Ethernet-APL utiliza uma amplitude diferencial próxima de <strong>2,4 Vpp</strong>, enquanto nos <strong>Spurs</strong> essa amplitude é reduzida para aproximadamente <strong>1,0 Vpp</strong>, preservando os requisitos de segurança intrínseca.</p>
<p>Essa amplitude é significativamente superior à encontrada nos fieldbuses convencionais, proporcionando uma melhor relação sinal/ruído (SNR), especialmente em longos trechos de cabo.</p>
<p>A consequência prática é uma maior imunidade a:</p>
<ul>
<li>interferências eletromagnéticas;</li>
<li>perdas por atenuação;</li>
<li>conectores envelhecidos;</li>
<li>pequenas variações de impedância;</li>
<li>degradação natural do cabeamento.</li>
</ul>
<p>Quanto maior a amplitude disponível no receptor, maior é a distância entre os níveis válidos do sinal e o nível de ruído presente na instalação.</p>
<p><strong>4.3.1.2 Robustez além da amplitude<br />
</strong>Entretanto, atribuir toda a robustez apenas ao aumento da tensão seria uma simplificação excessiva.</p>
<p>O Ethernet-APL incorpora recursos inexistentes nos fieldbuses clássicos, tais como:</p>
<ul>
<li>modulação PAM-3;</li>
<li>equalização adaptativa;</li>
<li>cancelamento adaptativo de eco;</li>
<li>recuperação digital de clock;</li>
<li>filtragem digital;</li>
<li>correção dinâmica das características do canal.</li>
</ul>
<p>Esses recursos permitem que o receptor acompanhe continuamente as alterações do meio físico, compensando automaticamente perdas introduzidas pelo cabo.</p>
<p><strong>4.3.1.3 Equalização adaptativa<br />
</strong>Em cabos longos ocorre uma atenuação progressiva das componentes de alta frequência.</p>
<p>No PROFIBUS-PA e Foundation fieldbus essa degradação reduz diretamente a qualidade do sinal recebido.</p>
<p>No Ethernet-APL, o equalizador adaptativo mede continuamente a resposta do canal e ajusta automaticamente seu ganho em diferentes frequências.</p>
<p>Como resultado, parte da atenuação provocada pelo cabo pode ser compensada eletronicamente.</p>
<p><strong>4.3.1.4 Cancelamento de eco<br />
</strong>Outra característica exclusiva é o cancelamento adaptativo de eco.</p>
<p>Como a transmissão ocorre em <strong>full-duplex</strong> sobre um único par de fios, o receptor recebe simultaneamente:</p>
<ul>
<li>o sinal proveniente do equipamento remoto;</li>
<li>uma cópia do próprio sinal transmitido.</li>
</ul>
<p>O PHY estima matematicamente esse eco e o subtrai em tempo real, permitindo separar os dois fluxos de comunicação.</p>
<p>Essa técnica aumenta significativamente a imunidade a reflexões e descontinuidades do canal.</p>
<p><strong>4.3.1.5 Comunicação diferencial<br />
</strong>Assim como os fieldbuses modernos, o Ethernet-APL utiliza transmissão diferencial.</p>
<p>A diferença está na qualidade do processamento realizado após a recepção.</p>
<p>Mesmo quando ruídos de modo comum são parcialmente convertidos em ruído diferencial devido a problemas de instalação, o PHY ainda dispõe de mecanismos digitais para recuperar o sinal.</p>
<p><strong>4.3.1.6 Melhor aproveitamento da energia do sinal<br />
</strong>Outro aspecto importante é que o sinal PAM-3 distribui a informação em três níveis de tensão.</p>
<p>Isso melhora a eficiência espectral e reduz a largura de banda necessária para transmitir a mesma quantidade de dados.</p>
<p>Além disso, a codificação utilizada evita sequências longas de símbolos iguais, reduzindo componentes contínuas e facilitando tanto a equalização quanto a recuperação de clock.</p>
<p><strong>4.3.1.7 Margem operacional<br />
</strong>Em instalações industriais é comum encontrar:</p>
<ul>
<li>cabos antigos;</li>
<li>conectores parcialmente oxidados;</li>
<li>pequenas infiltrações de umidade;</li>
<li>variações de temperatura;</li>
<li>interferência de inversores de frequência;</li>
<li>motores de grande porte.</li>
</ul>
<p>Enquanto essas condições podem degradar rapidamente sistemas de baixa velocidade e processamento analógico, o Ethernet-APL mantém uma margem operacional muito maior devido ao conjunto formado por:</p>
<ul>
<li>maior amplitude de transmissão;</li>
<li>elevada relação sinal/ruído;</li>
<li>processamento digital do PHY;</li>
<li>algoritmos adaptativos;</li>
<li>transmissão diferencial balanceada.</li>
</ul>
<p style="text-align: left;"><strong>Comparação entre Ethernet-APL e Fieldbuses Tradicionais</strong></p>
<table class=" aligncenter" style="height: 683px;" width="577">
<thead>
<tr>
<td>
<p style="text-align: left;"><strong>Característica</strong></p>
</td>
<td style="text-align: left;"><strong>PROFIBUS-PA / FF H1</strong></td>
<td style="text-align: center;">
<p style="text-align: left;"><strong>Ethernet-APL</strong></p>
</td>
</tr>
</thead>
<tbody>
<tr>
<td>Taxa de transmissão</td>
<td>31,25 kbit/s</td>
<td>10 Mbit/s</td>
</tr>
<tr>
<td>Amplitude típica do sinal</td>
<td>Menor</td>
<td>Até 2,4 Vpp (Trunk)</td>
</tr>
<tr>
<td>Comunicação</td>
<td>Half-Duplex</td>
<td>Full-Duplex</td>
</tr>
<tr>
<td>Modulação</td>
<td>Manchester</td>
<td>PAM-3</td>
</tr>
<tr>
<td>Equalização adaptativa</td>
<td>Não</td>
<td>Sim</td>
</tr>
<tr>
<td>Cancelamento de eco</td>
<td>Não</td>
<td>Sim</td>
</tr>
<tr>
<td>Recuperação digital de clock</td>
<td>Limitada</td>
<td>Avançada</td>
</tr>
<tr>
<td>Processamento do canal</td>
<td>Analógico</td>
<td>DSP dedicado</td>
</tr>
<tr>
<td>Robustez a degradação do cabo</td>
<td>Média</td>
<td>Elevada</td>
</tr>
<tr>
<td style="text-align: left;">Imunidade a ruídos industriais</td>
<td style="text-align: left;">Boa</td>
<td>
<p style="text-align: left;">Muito elevada</p>
</td>
</tr>
</tbody>
</table>
<p style="text-align: center;"><em>Tabela 3 &#8211; Comparação entre Ethernet-APL e Fieldbuses Tradicionais</em></p>
<p>A maior robustez do Ethernet-APL resulta da integração entre um sinal elétrico com maior margem (principalmente no Trunk), uma modulação mais eficiente e um conjunto de algoritmos avançados implementados no PHY. Essa combinação permite que a rede mantenha comunicação confiável mesmo em condições de instalação desafiadoras, com longos cabos, interferências eletromagnéticas, pequenas degradações do meio físico e variações ambientais.</p>
<p>Em outras palavras, o Ethernet-APL não é apenas um &#8220;fieldbus mais rápido&#8221;. Ele representa uma nova geração de camada física, projetada para explorar técnicas modernas de processamento digital de sinais e garantir alta confiabilidade nas aplicações de automação de processos, sem abrir mão da compatibilidade com os requisitos de segurança intrínseca e das grandes distâncias exigidas pela indústria de processo.</p>
<p><strong>5. Formas de Onda do Sinal APL<br />
</strong>Para facilitar a compreensão prática do comportamento do sinal na camada física, vejamos as formas de ondas com a modulação PAM-3 com três níveis de amplitude, a 10 Mbaud e transições suaves representativas de equalização e pulse shaping implementados no PHY.</p>
<p>A Figura 5 apresenta um exemplo detalhado do sinal diferencial no Trunk, com amplitude de aproximadamente 2,4 Vpp (níveis em ±1,2 V). Note-se a presença dos três níveis distintos da modulação PAM-3 e a estrutura temporal dos símbolos.</p>
<p style="text-align: center;"><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-13066" src="https://www.profibus.org.br/wp-content/uploads/2026/07/F-5-scaled.png" alt="" width="2560" height="832" srcset="https://www.profibus.org.br/wp-content/uploads/2026/07/F-5-scaled.png 2560w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-5-300x98.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-5-1024x333.png 1024w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-5-768x250.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-5-1536x499.png 1536w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-5-2048x666.png 2048w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-5-555x180.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-5-1110x361.png 1110w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-5-600x195.png 600w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-5-1200x390.png 1200w" sizes="(max-width: 2560px) 100vw, 2560px" /></p>
<p style="text-align: center;"><em>Figura 5 &#8211; Forma de onda ilustrativa do sinal diferencial APL no Trunk (~2,4 Vpp). Modulação PAM-3 com níveis em aproximadamente +1,2 V / 0 V / −1,2 V. A amplitude maior garante melhor SNR em distâncias de até 1.000 m.</em></p>
<p>A comparação direta entre Trunk e Spur (Figura 6) evidencia a diferença crítica de amplitude para a mesma sequência de símbolos. Enquanto o Trunk opera com ~2,4 Vpp para maximizar desempenho em distância, o Spur opera com ~1,0 Vpp para limitar rigorosamente a energia disponível, requisito fundamental para a certificação intrinsecamente segura segundo o conceito 2-WISE.</p>
<p><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-13067" src="https://www.profibus.org.br/wp-content/uploads/2026/07/F-6-scaled.png" alt="" width="2560" height="927" srcset="https://www.profibus.org.br/wp-content/uploads/2026/07/F-6-scaled.png 2560w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-6-300x109.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-6-1024x371.png 1024w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-6-768x278.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-6-1536x556.png 1536w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-6-2048x742.png 2048w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-6-555x201.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-6-1110x402.png 1110w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-6-600x217.png 600w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-6-1200x435.png 1200w" sizes="(max-width: 2560px) 100vw, 2560px" /></p>
<p style="text-align: center;"><em>Figura 6 &#8211; Comparação das formas de onda do sinal APL: Trunk (~2,4 Vpp) versus Spur (~1,0 Vpp) para a mesma sequência de símbolos PAM-3. A redução de amplitude no Spur é intencional e essencial para segurança intrínseca em áreas classificadas (Zonas 0/1).</em></p>
<p><strong>6. Topologia Trunk-and-Spur e Componentes do Meio Físico<br />
</strong>A comunicação até o nível de campo é extremamente rápida graças à taxa de 10 Mbit/s. Os operadores da planta conseguem tomar decisões com base em informações detalhadas fornecidas pela tecnologia em tempo real. O acesso rápido e direto aos dispositivos, com dados de processo e diagnósticos avançados, facilita a manutenção preditiva, permitindo identificar anomalias antes que causem falhas nos equipamentos.</p>
<p>Essa arquitetura permite que até aproximadamente 50 dispositivos de campo sejam alimentados por segmento (dependendo da classe de potência e seção do cabo), mantendo a simplicidade de instalação e a robustez típica de redes de campo.</p>
<ul>
<li>Número de Field Switches conectados ao tronco alimentado</li>
<li>Número de dispositivos de campo conectados e seu consumo de potência</li>
<li>Bitola do cabo utilizado</li>
<li>Temperatura ambiente ao longo do cabo</li>
<li>Classificação da área (Zona 1 / Zona 2)</li>
</ul>
<p>O Ethernet-APL suporta qualquer topologia, porém a arquitetura trunk-and-spur é a mais recomendada para plantas de processo. O comprimento máximo do tronco depende de vários fatores:</p>
<p>Diferentemente das caixas de junção passivas utilizadas em PROFIBUS-PA, no Ethernet-APL as caixas de junção são substituídas pelos APL Field Switches, que são dispositivos ativos e inteligentes.</p>
<ul>
<li>Spur (Derivação): Cabo que liga o Field Switch ao dispositivo de campo (sensor, transmissor, posicionador de válvula etc.). Distância máxima de 200 m em configuração intrinsecamente segura (2-WISE).</li>
<li>Field Switch: Switch de campo com portas Trunk_in / Trunk_out e múltiplas portas Spur (normalmente 8 a 16 portas). Responsável por distribuir o sinal para os instrumentos de campo.</li>
<li>Trunk (Tronco): Cabo principal que distribui sinal e potência entre o Power Switch e os Field Switches. Distância máxima de até 1.000 m (Categoria IV).</li>
<li>Power Switch: Dispositivo de infraestrutura que converte Ethernet industrial convencional (100/1000 Mbit/s) para o sinal APL de 10 Mbit/s e injeta potência no tronco.</li>
</ul>
<p>Os principais componentes dessa arquitetura são:</p>
<p>A topologia recomendada e padronizada pelo Ethernet-APL é a do tipo trunk-and-spur (tronco e ramais), muito similar à utilizada em PROFIBUS PA e Foundation Fieldbus H1, porém com capacidade muito superior de dados e potência.</p>
<p><img loading="lazy" decoding="async" class="aligncenter  wp-image-13068" src="https://www.profibus.org.br/wp-content/uploads/2026/07/F-7.png" alt="" width="686" height="386" srcset="https://www.profibus.org.br/wp-content/uploads/2026/07/F-7.png 1366w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-7-300x169.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-7-1024x576.png 1024w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-7-768x432.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-7-555x312.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-7-1110x624.png 1110w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-7-600x337.png 600w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-7-1200x675.png 1200w" sizes="(max-width: 686px) 100vw, 686px" /></p>
<p style="text-align: center;"><em>Figura 7 &#8211; Aplicações integradas com redes Ethernet, dados em nuvem, análise de dados</em></p>
<p><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-13076" src="https://www.profibus.org.br/wp-content/uploads/2026/07/F-8.png" alt="" width="599" height="380" srcset="https://www.profibus.org.br/wp-content/uploads/2026/07/F-8.png 599w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-8-300x190.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-8-555x352.png 555w" sizes="(max-width: 599px) 100vw, 599px" /></p>
<p style="text-align: center;"><em>Figura 8 &#8211; Ethernet APL x Ethernet Industrial</em></p>
<p><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-13069" src="https://www.profibus.org.br/wp-content/uploads/2026/07/F-9.png" alt="" width="589" height="323" srcset="https://www.profibus.org.br/wp-content/uploads/2026/07/F-9.png 589w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-9-300x165.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-9-555x304.png 555w" sizes="(max-width: 589px) 100vw, 589px" /></p>
<p style="text-align: center;"><em>Figura 9 &#8211; Ethernet APL x Área Classificada</em></p>
<p>Alguns pontos marcantes que fazem a diferença:</p>
<ul>
<li>Permite até 60W de alimentação em áreas não classificadas</li>
<li>maior quantidade de equipamentos: até 50 dispositivos de campo de até 500 mW cada um</li>
<li>em conjunto com comunicação operando à velocidade de 10 Mbps usando apenas 1 par de fios.</li>
<li>O comprimento ponto a ponto máximo é de 1000 m e spurs de até 200 m.</li>
<li>O cabo adotado deve atender a IEC 61158-2 (AWG 22-14), permitindo aos clientes de PROFIBUS-PA conservar o investimento realizado em infraestrutura de cabeamento</li>
</ul>
<p style="text-align: center;"><em> <img loading="lazy" decoding="async" class="aligncenter  wp-image-13070" src="https://www.profibus.org.br/wp-content/uploads/2026/07/F-10.png" alt="" width="642" height="351" srcset="https://www.profibus.org.br/wp-content/uploads/2026/07/F-10.png 658w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-10-300x164.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-10-555x304.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-10-600x328.png 600w" sizes="(max-width: 642px) 100vw, 642px" /></em></p>
<p style="text-align: center;"><em>Figura 10 &#8211; Ethernet APL x Cabos</em></p>
<p>A topologia pode ser do tipo trunk e spurs. As caixas de junção e proteção, utilizadas em instalações PROFIBUS-PA para isolar curtos e facilitar a manutenção são agora substituídas pelos chamados APL Field Switches.</p>
<p>Na verdade, o Ethernet-APL suporta qualquer topologia. O tronco pode ter uma distância máxima de 1000m com alimentação externa, sendo que isto dependerá:</p>
<ul>
<li>Número de APL field switches conectados ao APL trunk alimentado</li>
<li>Número de APL field devices conectados, field switches e o consumo deles</li>
<li>Bitola do cabo</li>
<li>Temperatura no cabo</li>
<li>Classificação de área</li>
</ul>
<p><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-13071" src="https://www.profibus.org.br/wp-content/uploads/2026/07/F-11.png" alt="" width="626" height="331" srcset="https://www.profibus.org.br/wp-content/uploads/2026/07/F-11.png 626w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-11-300x159.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-11-555x293.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-11-600x317.png 600w" sizes="(max-width: 626px) 100vw, 626px" /></p>
<p style="text-align: center;"><em>Figura 11 &#8211; Ethernet APL x Topologia</em></p>
<p>A comunicação até o nível de campo é extremamente rápida graças à rápida taxa de dados de 10 MBit/s. Os operadores da planta são capazes de tomar as decisões certas com base em informações detalhadas sobre as operações da planta fornecidas pela tecnologia. A comunicação padronizada de alta velocidade em todos os níveis torna o status geral da planta acessível em tempo real. O acesso rápido e direto ao dispositivo, com dados do processo e dados de diagnóstico facilita a manutenção preditiva, pois as anomalias podem ser identificadas no estágio inicial antes que possam causar falha no equipamento. Portas de diagnósticos estão presentes. Veja a figura a seguir.</p>
<p><em> <img loading="lazy" decoding="async" class="aligncenter size-full wp-image-13072" src="https://www.profibus.org.br/wp-content/uploads/2026/07/F-12.png" alt="" width="640" height="361" srcset="https://www.profibus.org.br/wp-content/uploads/2026/07/F-12.png 640w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-12-300x169.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-12-555x312.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-12-600x338.png 600w" sizes="(max-width: 640px) 100vw, 640px" /></em></p>
<p style="text-align: center;"><em>Figura 12 &#8211; Ethernet APL x Diagnósticos</em></p>
<p><strong>7. Fornecimento de Potência sobre o Sinal (Power over APL)<br />
</strong>Uma das grandes vantagens do Ethernet-APL é a capacidade de fornecer potência e dados simultaneamente pelo mesmo par de fios, eliminando a necessidade de cabos de alimentação separados na maioria dos casos. Existem classes de potência bem definidas nos port profiles:</p>
<ul>
<li><strong>Spur – Classe A: </strong>15 V / 0,54 W (adequado para a maioria dos instrumentos de baixo consumo)</li>
<li><strong>Spur – Classe C: </strong>15 V / 1,1 W (para dispositivos com maior demanda, ex.: posicionadores inteligentes)</li>
<li><strong>Trunk – Classes 3 e 6: </strong>até 50 V / 57,5 W ou 92 W (para alimentar vários Field Switches e seus spurs)</li>
</ul>
<p>O conceito de 2-WISE (2-Wire Intrinsically Safe Ethernet) define os parâmetros de entidade (Ui, Ii, Pi, Ci, Li) que devem ser respeitados para garantir segurança intrínseca em spurs.</p>
<p><strong>8. Segurança Intrínseca – Conceito 2-WISE<br />
</strong>O Ethernet-APL foi projetado desde o início para operar em áreas classificadas (Zonas 0, 1, 2 / Div 1, 2). O conceito <strong>2-WISE</strong> (IEC TS 60079-47) permite que o spur seja intrinsecamente seguro, possibilitando:</p>
<ul>
<li>Manutenção ao vivo (live work) sem necessidade de permissão de trabalho a quente</li>
<li>Substituição de instrumentos em área classificada sem desligar o segmento</li>
<li>Parâmetros de entidade universais que simplificam a certificação do sistema</li>
<li>Uso de barreiras de segurança intrínseca simplificadas ou integradas nos switches</li>
</ul>
<p>A amplitude reduzida do sinal no spur (1,0 Vpp) e os limites rigorosos de potência são fundamentais para manter a energia abaixo dos níveis de ignição para gases do grupo IIC (mais sensíveis).</p>
<p><strong>9. Requisitos de Cabo e Parâmetros Elétricos do Meio Físico</strong><br />
Uma grande vantagem prática é a possibilidade de <strong>reutilizar cabos de fieldbus existentes</strong> (PROFIBUS PA / Foundation Fieldbus Type A). O cabo deve atender a:</p>
<ul>
<li>Impedância característica: 100 Ω ± 20% (faixa de frequência relevante)</li>
<li>Blindagem individual + blindagem geral (shielded twisted pair)</li>
<li>Seção condutor: tipicamente 0,75 mm² a 2,5 mm² (AWG 18 a 14)</li>
<li>Resistência de loop: ≤ 15 Ω/km (para minimizar queda de tensão em trechos longos)</li>
<li>Baixa capacitância e indutância por unidade de comprimento</li>
</ul>
<p>O Engineering Guideline define quatro categorias de cabo (I a IV) que determinam as distâncias máximas permitidas no trunk e no spur. A Categoria IV permite os valores máximos (1.000 m trunk / 200 m spur).</p>
<p><strong>10. Comparação com Tecnologias Legadas<br />
</strong>A tabela a seguir resume as principais diferenças entre o sinal APL e as tecnologias tradicionais de instrumentação de processo:</p>
<table class=" aligncenter" width="643">
<tbody>
<tr>
<td width="140"><strong>Característica</strong></td>
<td width="160"><strong>4-20 mA + HART</strong></td>
<td width="173"><strong>PROFIBUS PA / FF H1</strong></td>
<td width="169"><strong>Ethernet-APL</strong></td>
</tr>
<tr>
<td width="140"><strong>Taxa de comunicação</strong></td>
<td width="160">~1,2 kbit/s (HART)</td>
<td width="173">31,25 kbit/s</td>
<td width="169">10 Mbit/s (300×)</td>
</tr>
<tr>
<td width="140"><strong>Sinal</strong></td>
<td width="160">Analógico + digital</td>
<td width="173">Digital Manchester</td>
<td width="169">Digital Ethernet (PAM-3)</td>
</tr>
<tr>
<td width="140"><strong>Cabo</strong></td>
<td width="160">Par trançado simples</td>
<td width="173">Type A (IEC 61158-2)</td>
<td width="169">Reutiliza Type A</td>
</tr>
<tr>
<td width="140"><strong>Topologia</strong></td>
<td width="160">Ponto a ponto</td>
<td width="173">Barramento linear</td>
<td width="169">Trunk + Spur (flexível)</td>
</tr>
<tr>
<td width="140"><strong>Potência no campo</strong></td>
<td width="160">Loop-powered</td>
<td width="173">Bus-powered (~few mA)</td>
<td width="169">Alta potência (PoDL)</td>
</tr>
<tr>
<td width="140"><strong>Integração IT/OT</strong></td>
<td width="160">Gateways complexos</td>
<td width="173">Gateways / proxies</td>
<td width="169">Nativa Ethernet</td>
</tr>
<tr>
<td width="140"><strong>Diagnósticos / IIoT</strong></td>
<td width="160">Limitado</td>
<td width="173">Moderado</td>
<td width="169">Avançado (alta banda)</td>
</tr>
<tr>
<td width="140"><strong>Segurança Intrínseca</strong></td>
<td width="160">Sim (barreiras)</td>
<td width="173">Sim (FISCO / Entity)</td>
<td width="169">2-WISE nativo (live work)</td>
</tr>
</tbody>
</table>
<p style="text-align: center;"><em>Tabela 4 &#8211; Comparação do sinal APL com tecnologias legadas de automação de processos.</em></p>
<p><strong>11. Vantagens Estratégicas para a Indústria 4.0</strong></p>
<ul>
<li><strong>Velocidade: </strong>10 Mbit/s permite transmitir não apenas variáveis de processo, mas também diagnósticos avançados, dados brutos de sensores, logs de manutenção e até atualizações de firmware em tempo razoável.</li>
<li><strong>Integração nativa: </strong>Dispositivos APL aparecem como nós Ethernet padrão. Não são necessários gateways complexos para conectar ao sistema supervisório, MES, ERP ou nuvem.</li>
<li><strong>Manutenção preditiva: </strong>Alta banda permite estratégias de Condition Monitoring muito mais sofisticadas (vibração, espectro, tendências, etc.).</li>
<li><strong>Convergência de protocolos: </strong>O mesmo meio físico pode transportar PROFINET, EtherNet/IP, Modbus TCP, OPC UA, HART-IP etc. simultaneamente.</li>
<li><strong>Redução de complexidade: </strong>Menos tipos de cabo, menos barreiras, topologia mais flexível e menor necessidade de treinamento específico de fieldbus.</li>
<li><strong>Futuro-proof: </strong>Prepara a planta para os próximos 15-20 anos de evolução digital sem necessidade de substituição massiva da infraestrutura de cabeamento.</li>
</ul>
<p><strong>12. Considerações de Implementação<br />
</strong><strong>12.1 Projetos<br />
</strong>Para projetos que envolvem o sinal APL, recomenda-se observar os seguintes pontos:</p>
<ul>
<li>Realizar estudo de carga de rede (network load) — o Engineering Guideline recomenda manter carga &lt; 20% para boa performance.</li>
<li>Dimensionar corretamente a seção do cabo do trunk para minimizar queda de tensão quando há alimentação de potência.</li>
<li>Verificar compatibilidade de port profiles entre Power Switch, Field Switches e dispositivos de campo.</li>
<li>Em áreas classificadas, elaborar o documento descritivo do sistema 2-WISE conforme IEC TS 60079-47.</li>
<li>Aproveitar a oportunidade de reutilizar cabos existentes de fieldbus, desde que atendam aos parâmetros elétricos exigidos.</li>
<li>Planejar a migração gradual: é possível coexistir APL com 4-20 mA/HART e fieldbuses legados na mesma planta.</li>
</ul>
<p><strong>13. Problemas de Instalação</strong><br />
Embora o Ethernet-APL seja um padrão robusto e bem projetado, a camada física apresenta desafios práticos significativos durante a instalação e operação em ambientes industriais reais. Vamos exploras alguns pontos e as melhores práticas para evitá-los.</p>
<p><strong>13.1 Reutilização de Cabos Fieldbus Antigos<br />
</strong>Um dos maiores atrativos do Ethernet-APL é a possibilidade de reutilizar cabos Type A de PROFIBUS-PA / Foundation Fieldbus. No entanto, isso é também uma das maiores fontes de problemas em campo:</p>
<ul>
<li>Impedância fora da faixa: Cabos antigos podem apresentar impedância muito diferente de 100 Ω ±20% na faixa de frequência do APL (devido a envelhecimento, umidade ou danos mecânicos). Isso causa reflexões e degradação do sinal.</li>
<li>Resistência de loop alta: Cabos com condutores finos ou oxidados geram queda de tensão excessiva no Trunk, reduzindo a potência disponível nos Field Switches.</li>
<li>Blindagem degradada: Tranças soltas ou corroídas comprometem a imunidade a ruído e a performance de EMC.</li>
<li>Emendas mal executadas: Conectores de emenda ou caixas de junção antigas introduzem descontinuidades de impedância severas.</li>
</ul>
<p><strong>13.2 Erros Comuns de Topologia e Comprimento</strong><br />
Violar os limites de comprimento é um erro frequente:</p>
<ul>
<li>Trunk &gt; 1.000 m (Categoria IV) ou comprimentos excessivos em categorias inferiores → alta atenuação</li>
<li>Spur &gt; 200 m em configuração 2-WISE → violação dos parâmetros de entidade e risco de certificação de segurança intrínseca.</li>
<li>Excesso de dispositivos por segmento sem verificação de carga de potência e tráfego de rede.</li>
</ul>
<p><strong>13.3 Aterramento e Blindagem<br />
</strong>O aterramento incorreto é uma das principais causas de problemas de ruído e instabilidade no APL. Recomenda-se fortemente o aterramento em ponto único (single-point grounding) no painel de controle, com continuidade da blindagem ao longo de todo o cabo. Aterramentos múltiplos podem criar loops de terra que captam ruído de modo comum.</p>
<p><strong>13.3.1 Conceito de Bonding Recomendado</strong><br />
É recomendado fortemente o uso de uma <strong>rede de equipotencialidade malhada (Meshed Common Bonding Network &#8211; CBN)</strong>. Quando existe uma boa CBN malhada, a configuração preferencial é conectar o shield do cabo <strong>em ambas as extremidades diretamente à CBN</strong>, com baixa impedância e grande área de contato.</p>
<p><strong>13.3.2 Regras para Áreas Classificadas (Ex)<br />
</strong>Este é um ponto mais crítico:</p>
<p>Em áreas classificadas, o aterramento do shield em <strong>ambas as pontas só é permitido</strong> se houver <strong>alta garantia de equipotencialidade</strong> entre as duas extremidades do cabo (conforme IEC 60079-14).</p>
<p><strong>13.3.3 Quando Usar Capacitor no Shield?<br />
</strong>Quando a equipotencialidade não puder ser garantida com alto grau de confiança (situação comum em plantas existentes ou grandes), recomenda-se:</p>
<ul>
<li>Uma ponta conectada diretamente à CBN</li>
<li>Outra ponta conectada via capacitor</li>
</ul>
<p>Essa configuração evita que correntes parasitas circulem pelo shield, o que é especialmente importante em atmosferas explosivas. Alguns dispositivos APL possuem jumper interno para selecionar entre conexão direta ou capacitiva.</p>
<p><strong>13.3.4 Vantagens e Desvantagens<br />
</strong><strong>Conexão em ambas as pontas (com boa CBN):</strong></p>
<ul>
<li>Melhor desempenho EMC geral</li>
<li>Melhor imunidade a campos magnéticos</li>
</ul>
<p><strong>Uso de capacitor em uma das pontas:</strong></p>
<ul>
<li>Evita correntes no shield (mais seguro em Ex)</li>
<li>Reduz imunidade contra campos magnéticos → exige maior separação física dos cabos de potência</li>
</ul>
<p><strong>13.3.5 Recomendações Práticas</strong></p>
<ul>
<li>Em projetos novos (greenfield): Buscar implementar uma CBN malhada de qualidade e conectar o shield em ambas as pontas.</li>
<li>Em retrofit ou plantas existentes: Avaliar o nível real de equipotencialidade. Na dúvida, adotar a solução com capacitor (especialmente em spurs em área classificada).</li>
<li>Priorizar conexões de baixa impedância (shield clamp em vez de rabichos longos).</li>
<li>Documentar claramente a estratégia de aterramento/blindagem</li>
</ul>
<p><strong>14. Ruído e Interferência Eletromagnética<br />
</strong>Ambientes industriais são hostis. Mesmo com sinalização diferencial e blindagem, o meio físico do APL pode sofrer com:</p>
<table class=" aligncenter" width="643">
<tbody>
<tr>
<td width="160"><strong>Problema</strong></td>
<td width="187"><strong>Causa Principal</strong></td>
<td width="147"><strong>Impacto</strong></td>
<td width="149"><strong>Mitigação</strong></td>
</tr>
<tr>
<td width="160"><strong>Ruído de modo comum</strong></td>
<td width="187">Acoplamento capacitivo/indutivo de cabos de potência, VFDs e motores</td>
<td width="147">Degradação do SNR, erros de bit</td>
<td width="149">Blindagem contínua + aterramento correto + separação física de cabos</td>
</tr>
<tr>
<td width="160"><strong>Reflexões por descontinuidade</strong></td>
<td width="187">Conectores ruins, emendas, mudança de tipo de cabo</td>
<td width="147">Jitter aumentado, diagrama de olho fechado</td>
<td width="149">Usar conectores recomendados APL + preparação correta do cabo</td>
</tr>
<tr>
<td width="160"><strong>Atenuação excessiva</strong></td>
<td width="187">Cabo longo + alta resistência de loop + temperatura elevada</td>
<td width="147">Redução de amplitude → pior BER</td>
<td width="149">Verificar categoria do cabo e queda de tensão calculada</td>
</tr>
<tr>
<td width="160"><strong>Crosstalk excessivo</strong></td>
<td width="187">Muitos cabos APL em eletrocalha sem separação adequada</td>
<td width="147">Interferência entre pares adjacentes</td>
<td width="149">Separar bundles ou usar cabos com blindagem individual reforçada</td>
</tr>
</tbody>
</table>
<p style="text-align: center;"><em>Tabela 5 &#8211; Principais problemas de ruído e interferência no meio físico APL.</em></p>
<p><strong>15. Jitter e desbalanceamento no Ethernet-APL<br />
</strong>Jitter (variação no tempo de chegada dos símbolos) é um parâmetro crítico no 10BASE-T1L. O padrão define limites rigorosos de jitter que o PHY deve tolerar para manter baixa taxa de erro de bit (BER).<strong> D</strong>e acordo com o padrão IEEE 802.3cg-2019 (base do Ethernet-APL) e o Ethernet-APL Engineering Guideline, o principal limite de jitter do transmissor especificado é de 10ns(peak-to-peak). O jitter é medido como Time Interval Error (TIE) entre símbolos consecutivos.</p>
<p>No contexto do Ethernet-APL, o jitter é mais crítico no Trunk (longa distância) do que no Spur.</p>
<p>A maioria dos PHYs comerciais de 10BASE-T1L (como DP83TD510E da TI, ADIN1100 da Analog Devices, etc.) são projetados para ficar bem abaixo desse limite (geralmente entre 2~6 ns em condições normais).</p>
<p>Em instalações com cabos longos, conectores ruins ou má equalização, o <strong>jitter efetivo no receptor</strong> pode aumentar devido a reflexões e ISI (Inter Symbol Interference).</p>
<p><strong>15.1 Fontes de Jitter no Meio Físico</strong></p>
<ul>
<li>Reflexões por mismatches de impedância: Conectores, emendas, mudança abrupta de seção de cabo ou tipo de cabo geram ecos que chegam ao receptor com atraso variável.</li>
<li>Equalização insuficiente: Em cabos longos ou de baixa qualidade, o equalizador adaptativo do PHY pode não conseguir compensar totalmente a distorção do canal.</li>
<li>Ruído de fase do clock recovery: Ruído de modo comum ou interferência que afeta o circuito de recuperação de clock do PHY.</li>
<li>Variação de temperatura: Parâmetros do cabo (atenuação, velocidade de propagação) mudam com temperatura, alterando o canal dinamicamente.</li>
</ul>
<p><strong>15.2 Impacto Prático do Jitter<br />
</strong>Jitter excessivo reduz a abertura do diagrama de olho, aumentando a probabilidade de amostragem incorreta pelo receptor. Em casos extremos, causa perda de link intermitente ou alta taxa de erros, especialmente em trunks longos operando próximo ao limite de 1.000 m. O PHY do APL possui circuitos robustos de equalização e cancelamento de eco, mas eles têm limites — não substituem uma instalação de qualidade.</p>
<p><strong>15.3 Desbalanceamento Do Sinal No Ethernet-APL</strong><br />
No Ethernet-APL, o sinal é transmitido de forma diferencial sobre um único par trançado balanceado. Qualquer desbalanceamento físico ou elétrico entre as duas pernas do par (APL+ e APL−) pode degradar significativamente o desempenho do sistema. Vejamos as principais causas de desbalanceamento, seus impactos e as recomendações para evitá-lo.</p>
<p><strong>15.3.1 O que é Desbalanceamento do Sinal?<br />
</strong>Desbalanceamento do sinal ocorre quando há uma assimetria entre os dois condutores do par diferencial. Isso faz com que parte do sinal diferencial se converta em modo comum (e vice-versa), prejudicando a imunidade a ruído e o desempenho do cancelamento de eco no PHY.</p>
<p>Diferente de sistemas de múltiplos pares (como 1000BASE-T), no APL não existe o conceito clássico de “skew entre pares”. O problema aqui é o desbalanceamento dentro do próprio par diferencial.</p>
<p><strong>15.3.2 Principais Causas de Desbalanceamento<br />
</strong>A tabela abaixo resume as causas mais comuns de desbalanceamento físico do sinal no Ethernet-APL:</p>
<table class=" aligncenter" width="643">
<tbody>
<tr>
<td width="213"><strong>Causa</strong></td>
<td width="213"><strong>Impacto</strong></td>
<td width="216"><strong>Recomendação</strong></td>
</tr>
<tr>
<td width="213"><strong>Cabo com mau balanceamento (baixa TCL)</strong></td>
<td width="213">Alta conversão de modo diferencial para comum</td>
<td width="216">Usar cabos certificados com bom TCL/ELTCTL</td>
</tr>
<tr>
<td width="213"><strong>Conectores assimétricos ou mal instalados</strong></td>
<td width="213">Descontinuidade de impedância e geração de modo comum</td>
<td width="216">Usar conectores de qualidade e instalar corretamente (evitar pigtails longos)</td>
</tr>
<tr>
<td width="213"><strong>Emendas ruins ou caixas de junção inadequadas</strong></td>
<td width="213">Reflexões e desbalanceamento local</td>
<td width="216">Evitar emendas sempre que possível. Quando inevitável, usar componentes de alta qualidade</td>
</tr>
<tr>
<td width="213"><strong>Diferença de comprimento entre as pernas do par</strong></td>
<td width="213">Skew efetivo e conversão de modo</td>
<td width="216">Manter comprimentos iguais nas duas pernas até o conector</td>
</tr>
<tr>
<td width="213"><strong>Conexão assimétrica do shield</strong></td>
<td width="213">Correntes de modo comum e ruído</td>
<td width="216">Conectar o shield com baixa impedância e de forma simétrica (preferir shield clamp)</td>
</tr>
<tr>
<td width="213"><strong>Torção irregular ou danos mecânicos no cabo</strong></td>
<td width="213">Alteração local da impedância e balanceamento</td>
<td width="216">Respeitar raio de curvatura mínimo e evitar torção excessiva durante a instalação</td>
</tr>
<tr>
<td width="213"><strong>Layout assimétrico na placa (PCB)</strong></td>
<td width="213">Desbalanceamento na interface MDI</td>
<td width="216">Manter traços simétricos, mesmo comprimento e impedância controlada</td>
</tr>
</tbody>
</table>
<p style="text-align: center;"><em>Tabela 6 &#8211; Principais causas de desbalanceamento do sinal no Ethernet-APL e recomendações.</em></p>
<p><strong>15.3.3 Impactos do Desbalanceamento<br />
</strong>O desbalanceamento físico do sinal pode causar os seguintes problemas:</p>
<ul>
<li><strong>Piora no desempenho do cancelamento de eco</strong> — o PHY tem mais dificuldade para separar o sinal transmitido do recebido.</li>
<li><strong>Aumento de ruído de modo comum</strong> — maior suscetibilidade a interferências eletromagnéticas.</li>
<li><strong>Fechamento do diagrama de olho</strong> — aumento da taxa de erro de bit (BER).</li>
<li><strong>Degradação da imunidade EMI/EMC</strong> — especialmente crítico em ambientes industriais com VFDs e motores.</li>
<li><strong>Possível impacto na certificação 2-WISE</strong> — em casos extremos de desbalanceamento em áreas classificadas.</li>
</ul>
<p>Os fabricantes de PHY normalmente trabalham aproximadamente com os seguintes valores de projeto.</p>
<table class=" aligncenter" style="height: 459px;" width="492">
<thead>
<tr>
<td><strong>Desbalanceamento</strong></td>
<td><strong>Situação</strong></td>
</tr>
</thead>
<tbody>
<tr>
<td>&lt; 1 %</td>
<td>Excelente</td>
</tr>
<tr>
<td>1–2 %</td>
<td>Muito bom</td>
</tr>
<tr>
<td>2–5 %</td>
<td>Normal</td>
</tr>
<tr>
<td>5–10 %</td>
<td>Começa a degradar margem</td>
</tr>
<tr>
<td>&gt;10 %</td>
<td>Pode haver redução significativa da imunidade</td>
</tr>
<tr>
<td>&gt;15 %</td>
<td>Alto risco de erros em cabos longos</td>
</tr>
</tbody>
</table>
<p style="text-align: center;"><em>Tabela 7 &#8211; Valores recomendados para desbalanceamento</em></p>
<p>Esses valores não são limites normativos, mas são recomendados para preservar boa margem de comunicação.</p>
<p>Embora não exista um limite oficial em porcentagem no Ethernet-APL, é recomendável como especificação de projeto para equipamentos e infraestrutura:</p>
<ul>
<li>Desbalanceamento de amplitude: ≤ 2% (ideal), máximo 5%.</li>
<li>Diferença de atraso (skew) entre os condutores: ≤ 5 ns por segmento.</li>
<li>Diferença de impedância entre os condutores: ≤ 2%.</li>
<li>Diferença de capacitância para terra: ≤ 5% entre os dois condutores.</li>
<li>Conversão modo comum → diferencial (LCL/LCTL): manter margem elevada conforme os requisitos do IEEE 802.3cg e dos testes de conformidade do Ethernet-APL.</li>
</ul>
<p>A seguir uma curva conceitual ilustrando a redução da margem operacional à medida que aumenta o desbalanceamento do canal diferencial. Não representa um limite normativo do IEEE 802.3cg.</p>
<p><img loading="lazy" decoding="async" class="aligncenter  wp-image-13073" src="https://www.profibus.org.br/wp-content/uploads/2026/07/F-13.png" alt="" width="705" height="429" srcset="https://www.profibus.org.br/wp-content/uploads/2026/07/F-13.png 989w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-13-300x183.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-13-768x467.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-13-555x338.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-13-600x365.png 600w" sizes="(max-width: 705px) 100vw, 705px" /></p>
<p style="text-align: center;"><em>Figura 13 &#8211; Curva conceitual ilustrando a redução da margem operacional à medida que aumenta o desbalanceamento do canal diferencial.</em></p>
<p>A curva pode ser explicada da seguinte forma:</p>
<ul>
<li><strong>0 a 2% de desbalanceamento</strong>: operação praticamente ideal. O receptor mantém ampla margem de decisão, elevada relação sinal/ruído (SNR), excelente rejeição de modo comum (CMRR) e o diagrama de olho permanece totalmente aberto.</li>
<li><strong>2 a 5%</strong>: ainda é uma condição considerada muito boa para aplicações industriais. Os algoritmos de equalização adaptativa e cancelamento de eco compensam facilmente as pequenas assimetrias do canal.</li>
<li><strong>5 a 10%</strong>: a margem começa a diminuir de forma perceptível. A conversão de ruído de modo comum para diferencial aumenta, o cancelador de eco passa a trabalhar com maior erro residual e o diagrama de olho começa a apresentar fechamento.</li>
<li><strong>Acima de 10%</strong>: a degradação torna-se significativa, principalmente em troncos longos (até 1000 m). O sistema ainda pode operar, mas com menor imunidade a interferências, maior probabilidade de erros de símbolo e aumento das retransmissões.</li>
<li><strong>Próximo de 15%</strong>: a operação pode se tornar instável, dependendo do comprimento do cabo, da qualidade da instalação, da umidade, da blindagem, do aterramento e do nível de ruído eletromagnético presente na planta.</li>
</ul>
<ul>
<li>aterramento e do nível de ruído eletromagnético presente na planta.</li>
</ul>
<p><img loading="lazy" decoding="async" class="aligncenter  wp-image-13074" src="https://www.profibus.org.br/wp-content/uploads/2026/07/F-14.png" alt="" width="711" height="474" srcset="https://www.profibus.org.br/wp-content/uploads/2026/07/F-14.png 1536w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-14-300x200.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-14-1024x683.png 1024w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-14-768x512.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-14-555x370.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-14-1110x740.png 1110w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-14-600x400.png 600w, https://www.profibus.org.br/wp-content/uploads/2026/07/F-14-1200x800.png 1200w" sizes="(max-width: 711px) 100vw, 711px" /></p>
<p style="text-align: center;"><em>Figura 14 &#8211; Sequência de diagramas de olho (Eye Diagrams) mostrando o efeito visual do desbalanceamento</em></p>
<table class=" aligncenter" style="height: 455px;" width="522">
<thead>
<tr>
<td>
<p style="text-align: left;"><strong>Desbalanceamento</strong></p>
</td>
<td style="text-align: left;"><strong>Aspecto do Eye Diagram</strong></td>
</tr>
</thead>
<tbody>
<tr>
<td>0%</td>
<td>Abertura máxima, excelente margem</td>
</tr>
<tr>
<td>2%</td>
<td>Praticamente inalterado</td>
</tr>
<tr>
<td>5%</td>
<td>Pequena redução da abertura vertical</td>
</tr>
<tr>
<td>10%</td>
<td>Fechamento visível do olho, aumento de jitter</td>
</tr>
<tr>
<td>15%</td>
<td>Olho parcialmente fechado, margem reduzida</td>
</tr>
<tr>
<td>20%</td>
<td>Forte sobreposição dos níveis e elevado risco de erro</td>
</tr>
</tbody>
</table>
<p style="text-align: center;"><em>Tabela 8 &#8211; Desbalanceamento x Aspecto do Eye Diagram</em></p>
<p><strong>15.3.4 Recomendações Práticas<br />
</strong>Com base no Ethernet-APL Engineering Guideline e boas práticas de instalação, recomenda-se:</p>
<ul>
<li><strong>Utilizar cabos com bom balanceamento</strong> (verificar parâmetros de TCL/ELTCTL quando possível).</li>
<li><strong>Preferir conectores de alta qualidade</strong> e realizar a instalação de forma simétrica (evitar rabichos longos no shield).</li>
<li><strong>Manter simetria física</strong> entre as duas pernas do par até o ponto de conexão.</li>
<li><strong>Evitar emendas sempre que possível</strong>. Quando necessário, usar componentes projetados para alta frequência.</li>
<li><strong>Respeitar raio de curvatura e torção do cabo</strong> durante a instalação.</li>
<li><strong>Verificar integridade do cabo antes de reutilizar</strong> cabos de fieldbus antigos.</li>
<li><strong>Manter layout simétrico na placa</strong> (quando o PHY estiver em placa própria).</li>
</ul>
<p><strong>16. Boas Práticas Recomendadas<br />
</strong>Com base em experiências de campo e recomendações do Ethernet-APL Engineering Guideline:</p>
<ul>
<li>Sempre medir os parâmetros do cabo antes de reutilizar (impedância, resistência de loop, isolamento). Não assumir que &#8216;era PROFIBUS-PA, então serve&#8217;.</li>
<li>Usar conectores e ferramentas de crimpagem/aperto recomendados pelos fabricantes de switches APL.</li>
<li>Respeitar rigorosamente as distâncias máximas por categoria de cabo (I a IV).</li>
<li>Realizar estudo de carga de potência e de tráfego de rede antes de dimensionar o segmento.</li>
<li>Aterrar a blindagem em um único ponto (preferencialmente no painel de controle). Evitar aterramentos múltiplos.</li>
<li>Separar fisicamente cabos APL de cabos de potência e VFDs sempre que possível.</li>
<li>Após instalação, realizar testes de link (BER, diagrama de olho se disponível) e verificação dos parâmetros 2-WISE antes de energizar em área classificada.</li>
</ul>
<p><strong>17. Influência da Umidade e da Resistência de Isolação na Integridade do Sinal Ethernet-APL<br />
</strong>A confiabilidade de uma rede Ethernet-APL depende não apenas da qualidade dos dispositivos eletrônicos e da topologia da rede, mas também das condições elétricas do meio físico. Entre os fatores ambientais que mais afetam a camada física destacam-se a umidade, a contaminação superficial, a condensação e a redução da resistência de isolamento dos cabos, conectores e caixas de junção.</p>
<p>Embora esses problemas também existam em redes 4–20 mA, HART e PROFIBUS-PA, seus efeitos tornam-se muito mais relevantes no Ethernet-APL devido à elevada taxa de transmissão, à modulação PAM-3 e ao uso de técnicas sofisticadas de equalização e cancelamento de eco.</p>
<p><strong>17.1 Resistência de isolação<br />
</strong>Idealmente, os dois condutores do cabo Ethernet-APL devem permanecer eletricamente isolados entre si e também em relação à blindagem e ao terra. Na prática, sempre existe uma resistência de fuga. Em uma instalação nova essa resistência normalmente é extremamente elevada, da ordem de dezenas ou centenas de megaohms.</p>
<p>Entretanto, diversos fatores podem reduzi-la ao longo da vida útil da instalação: umidade, condensação, penetração de água em conectores, sujeira industrial, poeira condutiva, depósitos de sal, fertilizantes, produtos químicos, óleo contaminado, corrosão, envelhecimento do isolamento e danos mecânicos no cabo.</p>
<p>Quando essa resistência diminui, surgem correntes de fuga que alteram o comportamento elétrico da linha.</p>
<p><strong>17.2 Umidade como caminho condutivo<br />
</strong>A água pura possui baixa condutividade elétrica. Porém, em ambientes industriais, a umidade raramente é pura. Ela normalmente contém sais minerais, partículas metálicas, resíduos químicos, ácidos, álcalis e poeiras condutivas. Esses contaminantes transformam a película de água em um caminho resistivo entre os condutores ou entre o condutor e a blindagem. Mesmo que a resistência permaneça relativamente elevada, ela pode modificar o equilíbrio do par diferencial.</p>
<p><strong>17.3 Consequências elétricas<br />
</strong>Uma baixa resistência de isolamento provoca diversos efeitos simultâneos:</p>
<ol>
<li>Redução da amplitude diferencial: Parte da energia do transmissor passa a circular pelas correntes de fuga. Como consequência, a amplitude efetiva do sinal recebido diminui. Esse efeito é particularmente crítico nos spurs, onde a amplitude diferencial já é reduzida para aproximadamente 1 Vpp.</li>
<li>Desbalanceamento do par: Se apenas um dos condutores apresentar fuga para a blindagem ou para o terra, o sistema deixa de ser perfeitamente balanceado. Isso reduz a rejeição de modo comum e aumenta a suscetibilidade à interferência eletromagnética. Ruídos que antes eram cancelados passam a aparecer como ruído diferencial.</li>
<li>Alteração da impedância característica: A resistência de fuga atua em paralelo com a impedância característica da linha. Embora essa alteração possa parecer pequena, ela modifica a resposta em frequência do canal, produzindo reflexões adicionais e alterando a resposta do equalizador adaptativo.</li>
<li>Aumento da atenuação: Além da resistência do cabo e da capacitância distribuída, passa a existir uma dissipação adicional de energia através da umidade. Essa perda reduz ainda mais a relação sinal/ruído disponível no receptor.</li>
</ol>
<p><strong>17.4 Influência sobre a modulação PAM-3<br />
</strong>A modulação PAM-3 exige que o receptor diferencie corretamente três níveis de tensão. Quando há fuga de corrente causada por baixa isolação, esses níveis deixam de ser perfeitamente definidos. Os níveis positivos e negativos aproximam-se do nível central, reduzindo a margem de decisão do circuito receptor. Esse fenômeno aumenta a probabilidade de erro na identificação dos símbolos transmitidos.</p>
<p><strong>17.5 Influência no diagrama de olho<br />
</strong>Um dos melhores indicadores da qualidade da camada física é o diagrama de olho. Quando existe baixa resistência de isolamento, normalmente observam-se: redução da abertura vertical, aumento do ruído, deslocamento do nível médio, maior dispersão das transições e fechamento parcial do diagrama de olho. Embora o equalizador adaptativo consiga compensar parte dessas alterações, sua capacidade possui limites.</p>
<p><strong>17.5.1 Interação com o cancelamento de eco<br />
</strong>O Ethernet-APL utiliza cancelamento adaptativo de eco para permitir comunicação full-duplex em um único par de fios. Esse algoritmo parte do princípio de que o canal apresenta comportamento relativamente estável. Quando existe umidade variável ou condensação, a impedância do canal muda continuamente. Como consequência, o modelo matemático utilizado pelo cancelador de eco deixa de representar corretamente a linha, aumenta o erro residual, parte do sinal transmitido permanece presente no receptor e diminui a margem para recuperação do sinal recebido. Em casos extremos, o PHY pode precisar reinicializar o processo de adaptação.</p>
<p><strong>17.6 Influência da condensação<br />
</strong>Em plantas de processo é comum ocorrer condensação dentro de caixas de junção, Field Switches ou instrumentos submetidos a grandes variações térmicas. Durante a madrugada, por exemplo, a temperatura pode cair abaixo do ponto de orvalho. Uma fina película de água forma-se sobre placas eletrônicas e conectores. Embora essa película seja quase imperceptível, ela pode reduzir significativamente a resistência superficial do isolamento. O efeito costuma ser intermitente, dificultando o diagnóstico. Frequentemente a rede apresenta falhas apenas nas primeiras horas da manhã e volta a operar normalmente após o aquecimento dos equipamentos.</p>
<p><strong>17.7 Diagnóstico em campo<br />
</strong>Problemas de baixa isolação normalmente apresentam sintomas como: perda intermitente de comunicação, aumento de erros CRC, retransmissões frequentes, dispositivos desconectando esporadicamente, falhas após chuva intensa, degradação durante períodos de elevada umidade relativa e recuperação espontânea após secagem. Esses sintomas são frequentemente confundidos com defeitos de hardware ou problemas de software.</p>
<p><strong>17.8 Boas práticas</strong><br />
Para minimizar os efeitos da umidade recomenda-se: utilizar conectores com grau de proteção adequado, evitar condensação através de respiros apropriados, inspecionar periodicamente caixas de junção, manter prensa-cabos corretamente instalados, utilizar cabos compatíveis com aplicações externas, evitar emendas expostas, monitorar a resistência de isolamento em programas de manutenção preditiva, substituir componentes com sinais de corrosão e manter a blindagem íntegra e continuamente conectada.</p>
<p><strong>17.9 Considerações finais<br />
</strong>Embora a tecnologia Ethernet-APL possua elevada robustez contra interferências eletromagnéticas, ela continua dependente da qualidade elétrica do meio físico. Umidade, condensação e baixa resistência de isolamento não provocam apenas aumento de ruído; elas alteram diretamente a impedância do canal, reduzem a amplitude do sinal diferencial, degradam o diagrama de olho e dificultam o funcionamento de algoritmos fundamentais como a equalização adaptativa e o cancelamento de eco.</p>
<p>Por essa razão, o controle da integridade do isolamento deve fazer parte das estratégias de projeto, instalação e manutenção de redes Ethernet-APL, garantindo que a infraestrutura física preserve a confiabilidade necessária para aplicações críticas de automação de processos ao longo de toda a vida útil da planta.</p>
<p><strong>18. Conclusão<br />
</strong>O Ethernet-APL representa muito mais do que uma simples evolução tecnológica. Ele constitui a infraestrutura física necessária para viabilizar a convergência real entre TI e OT até o nível de campo em áreas classificadas.</p>
<p>Ao padronizar o meio físico com comunicação full-duplex de 10 Mbit/s, modulação PAM-3, fornecimento integrado de potência e segurança intrínseca nativa (2-WISE), o padrão elimina limitações históricas que impediam a digitalização plena de plantas industriais.</p>
<p>Neste artigo, buscamos ir além da teoria, explorando aspectos práticos frequentemente negligenciados em projetos reais: as diferenças críticas entre Trunk e Spur, os desafios de reutilização de cabos legados, os cuidados com aterramento e blindagem, os limites de jitter e, principalmente, os impactos do desbalanceamento físico do sinal; um tema que, embora pouco discutido, está entre as principais causas de problemas de desempenho e instabilidade em campo.</p>
<p>A implementação bem-sucedida do Ethernet-APL depende tanto da compreensão técnica do meio físico quanto da qualidade da instalação. Cabos, conectores, aterramento, balanceamento do par e práticas de instalação têm impacto direto no desempenho do cancelamento de eco, na imunidade eletromagnética e na confiabilidade da comunicação.</p>
<p>Para a indústria brasileira, especialmente nos setores de óleo &amp; gás, petroquímica, açúcar e álcool, mineração e alimentos, o Ethernet-APL representa uma oportunidade estratégica de modernização. Mais do que velocidade, ele oferece acesso nativo a dados de alta qualidade, viabilizando estratégias avançadas de manutenção preditiva, otimização de processos e integração com sistemas corporativos, sem a necessidade de gateways complexos.</p>
<p>A Vivace Process Instruments acredita que o futuro da instrumentação de processos passa necessariamente pela adoção consciente e bem executada do Ethernet-APL. Por isso, continuamos investindo no desenvolvimento de conhecimento técnico, na formação de equipes e no desenvolvimento de soluções que permitam aos nossos clientes e parceiros aproveitarem todo o potencial dessa tecnologia de forma segura, confiável e com alto desempenho operacional.</p>
<p><strong>Referências e Fontes<br />
</strong>[1] Cassiolato, C. APL – Advanced Physical Layer. Artigo técnico, Vivace Process Instruments.<br />
[2] Ethernet-APL Organization. Ethernet-APL Engineering Guideline, Version 1.11, 2022.<br />
[3] IEEE Std 802.3cg-2019 – IEEE Standard for Ethernet Amendment 5: Physical Layer Specifications and Management Parameters for 10 Mb/s Operation and Associated Power Delivery over a Single Balanced Pair of Conductors.<br />
[4] IEC TS 60079-47 – Explosive atmospheres – Part 47: Equipment protection by 2-wire intrinsically safe Ethernet concept (2-WISE).<br />
[6] PROFIBUS &amp; PROFINET International (PI). Documentos técnicos sobre PROFINET over APL.<br />
[7] ODVA. Especificações e whitepapers sobre EtherNet/IP over Ethernet-APL.<br />
[8] Materiais Ethernet &#8211; APL César Cassiolato</p>
<p>&nbsp;</p>
<p><em>(<strong>*</strong>) <strong>César Cassiolato</strong>, CEO da Vivace Process Instruments LTDA</em></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.profibus.org.br/noticia/ethernet-apl-o-meio-fisico-que-esta-transformando-a-instrumentacao-instalacao-e-boas-praticas/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">13061</post-id>	</item>
		<item>
		<title>Switches Ethernet-APL elevando topologias legadas à era digital em poucos passos</title>
		<link>https://www.profibus.org.br/noticia/switches-ethernet-apl-elevando-topologias-legadas-a-era-digital-em-poucos-passos/</link>
					<comments>https://www.profibus.org.br/noticia/switches-ethernet-apl-elevando-topologias-legadas-a-era-digital-em-poucos-passos/#respond</comments>
		
		<dc:creator><![CDATA[Marketing]]></dc:creator>
		<pubDate>Tue, 05 May 2026 17:44:57 +0000</pubDate>
				<category><![CDATA[Artigo técnico]]></category>
		<guid isPermaLink="false">https://www.profibus.org.br/?p=12924</guid>

					<description><![CDATA[PEPPERL+FUCHS Quando o termo &#8220;Ethernet&#8221; é citado, a primeira imagem que vem à nossa mente é o cabo clássico com conector RJ45 que você pluga em um computador, em uma impressora ou até mesmo em um CLP no painel e, rapidamente, tudo já está se comunicando na rede sem grandes dificuldades. Essa é a experiência [&#8230;]]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><strong><a href="https://www.pepperl-fuchs.com/pt-br" target="_blank" rel="noopener">PEPPERL+FUCHS</a></strong></p>
<p><img loading="lazy" decoding="async" class="wp-image-12930 alignleft" src="https://www.profibus.org.br/wp-content/uploads/2026/05/PF-1.png" alt="" width="468" height="264" srcset="https://www.profibus.org.br/wp-content/uploads/2026/05/PF-1.png 806w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-1-300x169.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-1-768x433.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-1-555x312.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-1-600x338.png 600w" sizes="(max-width: 468px) 100vw, 468px" />Quando o termo &#8220;Ethernet&#8221; é citado, a primeira imagem que vem à nossa mente é o cabo clássico com conector RJ45 que você pluga em um computador, em uma impressora ou até mesmo em um CLP no painel e, rapidamente, tudo já está se comunicando na rede sem grandes dificuldades. Essa é a experiência fluida e instantânea que nos acostumamos a vivenciar no escritório ou nos níveis de TI. Mas, e no chão de fábrica? Se você atua na manutenção ou na engenharia de campo, sabe bem que a realidade é, na maioria das vezes, outra. Enquanto a TI voava, o nível de campo é um pouco mais moroso com as topologias tradicionais 4-20 mA ou de redes de campo mais lentas, que podem exigir um esforço maior para comissionamento, diagnóstico e comunicação. Ao mesmo tempo que a prioridade do chão de fábrica é manter a operação rodando com eficiência temos também a necessidade e desejo de preparar as instalações para Indústria 4.0. Isso nos leva para uma realidade orientada por dados e focada na mobilidade e conectividade, em que utilizar equipamentos que apenas informam os seus devidos dados de processo da variável, mas não conectam a sua operação a um nível mais inteligente e preditivo, pode se tornar um gargalo para a produtividade. Isso limita o alcance e a transparência do que realmente está acontecendo na sua planta.</p>
<p>É exatamente para quebrar essa barreira que o <strong>Ethernet-APL (Advanced Physical Layer)</strong> surge como o divisor de águas definitivo da Indústria 4.0. O desenvolvimento dessa tecnologia busca trazer esse mesmo nível simplicidade de conexão que temos no nosso dia a dia para o nível industrial. Essa virada de jogo estende a comunicação IP direta até o instrumento final, mesmo nas áreas classificadas mais críticas (Zonas 0, 1 e 2). Tudo isso entregando energia e comunicação de dados com velocidade <strong>10 Mbit/s</strong>, utilizando o mesmo e tradicional cabo de dois fios trançados que as instalações padrões de instrumentação estão habituados de Fieldbus tipo “A”.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-12931" src="https://www.profibus.org.br/wp-content/uploads/2026/05/PF-2.png" alt="" width="788" height="343" srcset="https://www.profibus.org.br/wp-content/uploads/2026/05/PF-2.png 1394w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-2-300x130.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-2-1024x445.png 1024w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-2-768x334.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-2-555x241.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-2-1110x483.png 1110w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-2-600x261.png 600w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-2-1200x522.png 1200w" sizes="(max-width: 788px) 100vw, 788px" /><br />
E é nesse ponto que o Switch Ethernet APL representa um dispositivo essencial para a transição de topologias legadas para uma arquitetura inovadora e flexível para que sua planta não se adapte a nova infraestrutura e sim o APL se adaptando a sua realidade.</p>
<p><strong><img loading="lazy" decoding="async" class="wp-image-12933 aligncenter" src="https://www.profibus.org.br/wp-content/uploads/2026/05/PF-33.png" alt="" width="386" height="272" srcset="https://www.profibus.org.br/wp-content/uploads/2026/05/PF-33.png 933w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-33-300x212.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-33-768x542.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-33-555x392.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-33-600x424.png 600w" sizes="(max-width: 386px) 100vw, 386px" /></strong></p>
<p>Neste artigo, conheça alguns recursos estratégicos pelas quais este Switch Ethernet APL traz uma engenharia simplificada e uma estratégia de transição para novos e antigos projetos.</p>
<p><strong><img decoding="async" class="aligncenter size-full wp-image-12929" src="https://www.profibus.org.br/wp-content/uploads/2026/05/PF-3.tif" alt="" /><a href="https://www.profibus.org.br/wp-content/uploads/2026/05/PF-3-1.tif"><img decoding="async" class="aligncenter size-full wp-image-12932" src="https://www.profibus.org.br/wp-content/uploads/2026/05/PF-3-1.tif" alt="" /></a>1. Aplicações em áreas seguras e áreas classificadas<br />
</strong>Tenha apenas uma infraestrutura para a comunicação de todos os instrumentos do seu processo.</p>
<p>Os switches Ethernet-APL “ARS*” permitem a comunicação contínua e rápida do nível de campo (em áreas classificas até a Zona 0) até o sistema de controle de processos e a nuvem.  Isso reduz o esforço de gerenciamento para instrumentação do projeto até a configuração, o comissionamento e a operação.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-12934 size-large" src="https://www.profibus.org.br/wp-content/uploads/2026/05/PF-44-1024x1024.jpg" alt="" width="1024" height="1024" srcset="https://www.profibus.org.br/wp-content/uploads/2026/05/PF-44-1024x1024.jpg 1024w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-44-300x300.jpg 300w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-44-150x150.jpg 150w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-44-768x768.jpg 768w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-44-1536x1536.jpg 1536w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-44-50x50.jpg 50w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-44-555x555.jpg 555w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-44-1110x1110.jpg 1110w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-44-600x600.jpg 600w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-44-1200x1200.jpg 1200w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-44.jpg 1636w" sizes="(max-width: 1024px) 100vw, 1024px" /><br />
<strong>2. WISE: 2 Wire Intrinsically Safe Ethernet<br />
</strong>Conecte instrumentos em área classificada via uma comunicação Ethernet intrinsecamente segura de 2 fios padronizada e sem cálculos complexos.</p>
<p>Com o padrão 2-WISE adotado pelos switches da Pepperl+Fuchs, se o instrumento e o switch são certificados 2-WISE, a malha é intrinsecamente segura por padrão e cálculos como parâmetros de entidade e outros não são mais necessários.</p>
<p><strong>3. Tecnologia Proxy Integrada para migração<br />
</strong>Modernize a rede de controle e troca a instrumentação PA /FF por APL no seu próprio ritmo, sem perder o investimento existente.</p>
<p>A série de Field switches ARS1* da Pepperl+Fuchs na sua essência permite a conexão de instrumentos modernos que se comunicam no meio físico APL, como os instrumentos PROFINET-APL comportando-se como um switch que junta o pacote de informação dos instrumentos e retransmite.</p>
<p>Mas ele também possui um &#8220;Proxy&#8221; nativo. Isso permite plugar um instrumento legado PROFIBUS-PA ou FOUNDATION Fieldbus H1 diretamente no Switch APL que  detecta automaticamente o instrumento fieldbus e passa a se comportar como um gateway, convertendo o sinal e traduzindo para PROFINET.</p>
<p><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-12925" src="https://www.profibus.org.br/wp-content/uploads/2026/05/PF-5.png" alt="" width="800" height="320" srcset="https://www.profibus.org.br/wp-content/uploads/2026/05/PF-5.png 800w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-5-300x120.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-5-768x307.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-5-555x222.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-5-600x240.png 600w" sizes="(max-width: 800px) 100vw, 800px" /></p>
<p><strong>4. Soluções em painéis montados e certificados<br />
</strong>A Pepperl+Fuchs projeta e entrega painéis pré-montados e totalmente certificados para Zona 2/22 com invólucros em aço inox ou fibra de vidro. Projetos podem ser elaborados com redundância de fonte, bornes e proteção contra surtos integrados. Trata-se de uma solução pronta para instalação e operação em campo com certificação para áreas classificadas.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-12926 size-full" src="https://www.profibus.org.br/wp-content/uploads/2026/05/PF-6-e1778523031539.png" alt="" width="932" height="245" srcset="https://www.profibus.org.br/wp-content/uploads/2026/05/PF-6-e1778523031539.png 932w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-6-e1778523031539-300x79.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-6-e1778523031539-768x202.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-6-e1778523031539-555x146.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-6-e1778523031539-600x158.png 600w" sizes="(max-width: 932px) 100vw, 932px" /></p>
<p><strong>5. Diagnósticos de Camada Física em Tempo Real<br />
</strong>A evolução de uma manutenção reativa cega para uma manutenção preditiva inteligente.</p>
<p>O Web Server integrado no switch permite monitorar a saúde do meio físico em tempo real (níveis de tensão, corrente, relação sinal-ruído e instabilidades) de cada porta individualmente. Além disso, se temos um instrumento Ethernet-APL conectado a porta do Switch, é possível acessar o IP individual de cada instrumento para obter informações e níveis de acessibilidade ainda mais avançadas e individualizando o ativo.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-12927" src="https://www.profibus.org.br/wp-content/uploads/2026/05/PF-7.png" alt="" width="788" height="443" srcset="https://www.profibus.org.br/wp-content/uploads/2026/05/PF-7.png 1443w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-7-300x169.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-7-1024x576.png 1024w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-7-768x432.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-7-555x312.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-7-1110x624.png 1110w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-7-600x337.png 600w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-7-1200x674.png 1200w" sizes="(max-width: 788px) 100vw, 788px" /></p>
<p>Os <strong>switches Ethernet-APL da Pepperl+Fuchs</strong> permitem a digitalização total de instrumentação reduzindo horas de engenharia e infraestrutura com alta acessibilidade de dados (Web Server, OPC UA, FDI) para aplicações inteligentes. O nível de campo ganhou o seu endereço IP.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-12928" src="https://www.profibus.org.br/wp-content/uploads/2026/05/PF-8.png" alt="" width="790" height="383" srcset="https://www.profibus.org.br/wp-content/uploads/2026/05/PF-8.png 1236w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-8-300x146.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-8-1024x497.png 1024w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-8-768x373.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-8-555x269.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-8-1110x539.png 1110w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-8-600x291.png 600w, https://www.profibus.org.br/wp-content/uploads/2026/05/PF-8-1200x583.png 1200w" sizes="(max-width: 790px) 100vw, 790px" /></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.profibus.org.br/noticia/switches-ethernet-apl-elevando-topologias-legadas-a-era-digital-em-poucos-passos/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">12924</post-id>	</item>
		<item>
		<title>Segurança IO-Link: O próximo passo seguro em um mundo de produção em rede</title>
		<link>https://www.profibus.org.br/noticia/seguranca-io-link-o-proximo-passo-seguro-em-um-mundo-de-producao-em-rede/</link>
					<comments>https://www.profibus.org.br/noticia/seguranca-io-link-o-proximo-passo-seguro-em-um-mundo-de-producao-em-rede/#respond</comments>
		
		<dc:creator><![CDATA[Marketing]]></dc:creator>
		<pubDate>Thu, 12 Mar 2026 16:19:17 +0000</pubDate>
				<category><![CDATA[Artigo técnico]]></category>
		<guid isPermaLink="false">https://www.profibus.org.br/?p=12825</guid>

					<description><![CDATA[Há mais de uma década, o IO-Link possibilitou um enorme avanço na inovação em automação industrial: desde então, sensores e atuadores inteligentes têm sido facilmente integrados a todos os ambientes de sistema, parametrizados de forma flexível e diagnosticados com confiabilidade. Essa tecnologia evoluiu para um poderoso padrão global, hoje essencial em ambientes de produção modernos. [&#8230;]]]></description>
										<content:encoded><![CDATA[<p><img loading="lazy" decoding="async" class="aligncenter wp-image-12826 " src="https://www.profibus.org.br/wp-content/uploads/2026/03/io-link-tech-e1773332243266.webp" alt="" width="378" height="78" srcset="https://www.profibus.org.br/wp-content/uploads/2026/03/io-link-tech-e1773332243266.webp 784w, https://www.profibus.org.br/wp-content/uploads/2026/03/io-link-tech-e1773332243266-300x62.webp 300w, https://www.profibus.org.br/wp-content/uploads/2026/03/io-link-tech-e1773332243266-768x159.webp 768w, https://www.profibus.org.br/wp-content/uploads/2026/03/io-link-tech-e1773332243266-555x115.webp 555w, https://www.profibus.org.br/wp-content/uploads/2026/03/io-link-tech-e1773332243266-600x124.webp 600w" sizes="(max-width: 378px) 100vw, 378px" /></p>
<p><span dir="auto">Há mais de uma década, o IO-Link possibilitou um enorme avanço na inovação em automação industrial: desde então, sensores e atuadores inteligentes têm sido facilmente integrados a todos os ambientes de sistema, parametrizados de forma flexível e diagnosticados com confiabilidade. Essa tecnologia evoluiu para um poderoso padrão global, hoje essencial em ambientes de produção modernos.</span></p>
<p><span dir="auto">Embora o IO-Link seja há muito tempo o estado da arte em automação, a demanda por soluções de segurança seguras, escaláveis ​​e altamente flexíveis, com tecnologia de sensores simples, aumentou simultaneamente. É exatamente nessa área que o IO-Link Safety se destaca, marcando mais um marco para a automação industrial como um todo. Desenvolvido para o uso industrial diário, o IO-Link Safety é o resultado de uma intensa colaboração entre diversas empresas e especialistas da comunidade IO-Link.</span></p>
<p><strong><span dir="auto">O objetivo era criar uma solução segura, universalmente utilizável, tecnicamente excelente e que funcionasse na automação do dia a dia — simples, robusta e aberta.</span></strong></p>
<p><span dir="auto">O IO-Link Safety atende ao Nível de Integridade de Segurança 3, cumprindo assim os elevados requisitos de engenharia mecânica e de plantas industriais, por exemplo. O protocolo de segurança é independente e universal, podendo ser mapeado para todos os outros protocolos de barramento de campo de segurança de nível superior. Com a especificação, os componentes certificados e a crescente aceitação no mercado global, o IO-Link Safety está pronto para uso generalizado.</span></p>
<p><strong><span dir="auto">Em conclusão: o futuro de tecnologias de sensores e atuadores mais simples e funcionalmente seguras está começando.</span></strong></p>
<p><span dir="auto">Desde robôs e máquinas de embalagem até sistemas intralogísticos e máquinas de trabalho móveis, os produtos com IO-Link Safety oferecem novos conceitos de segurança para máquinas e sistemas onde flexibilidade e segurança precisam coexistir. Por exemplo, sensores de distância básicos agora podem transmitir valores de processo seguros através do mesmo cabo padrão. A conexão a um sistema de controle voltado para segurança, como o Profisafe, também é possível e já foi implementada. IO-Link Safety é mais do que apenas um novo recurso; é o próximo passo lógico rumo a uma produção flexível, baseada em dados, totalmente conectada em rede e segura.</span></p>
<p><strong><span dir="auto">Seguindo os passos do padrão IO-Link, o IO-Link Safety trilhará o mesmo caminho de crescimento, possibilitando uma ampla variedade de produtos.</span></strong></p>
<p><span dir="auto">A comunidade IO-Link está ansiosa para acompanhar essa jornada e ver sua disseminação em diversas aplicações.</span></p>
<p><em><span dir="auto"><strong><img loading="lazy" decoding="async" class="wp-image-11843  alignleft" src="https://profinews.com/wp-content/uploads/2025/08/Frank_Moritz_feature-e1773253308299-300x266.jpg" sizes="(max-width: 300px) 100vw, 300px" srcset="https://profinews.com/wp-content/uploads/2025/08/Frank_Moritz_feature-e1773253308299-300x266.jpg 300w, https://profinews.com/wp-content/uploads/2025/08/Frank_Moritz_feature-e1773253308299.jpg 610w" alt="" width="240" height="213" /></strong></span></em></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><em><span dir="auto"><strong>Frank Moritz,</strong><br />
</span><span dir="auto">Conselho Executivo da PROFIBUS Nutzerorganisation eV.</span></em></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><em>&#8211; Conteúdo original disponível no s<a href="https://profinews.com/2026/03/io-link-safety-the-next-safe-step-in-a-networked-production-world/" target="_blank" rel="noopener">ite da PI</a>.</em></p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.profibus.org.br/noticia/seguranca-io-link-o-proximo-passo-seguro-em-um-mundo-de-producao-em-rede/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">12825</post-id>	</item>
		<item>
		<title>Monitoramento completo de redes PROFINET</title>
		<link>https://www.profibus.org.br/noticia/monitoramento-completo-de-redes-profinet/</link>
					<comments>https://www.profibus.org.br/noticia/monitoramento-completo-de-redes-profinet/#respond</comments>
		
		<dc:creator><![CDATA[Marketing]]></dc:creator>
		<pubDate>Tue, 10 Mar 2026 14:29:46 +0000</pubDate>
				<category><![CDATA[Artigo técnico]]></category>
		<guid isPermaLink="false">https://www.profibus.org.br/?p=12793</guid>

					<description><![CDATA[TOLEDO E SOUZA Resumo Redes Ethernet industriais seguem liderando novas instalações e modernizações, com PROFINET concentrando grande parte dos projetos, especialmente onde disponibilidade e determinismo são mandatórios. Nesse contexto, a robustez de uma rede PROFINET não depende apenas de projeto e comissionamento, ela depende de evidência contínua de saúde operacional. Na prática, falhas raramente surgem [&#8230;]]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><a href="https://toledoesouza.com/" target="_blank" rel="noopener"><strong>TOLEDO E SOUZA</strong></a></p>
<p><strong>Resumo<br />
</strong>Redes Ethernet industriais seguem liderando novas instalações e modernizações, com PROFINET concentrando grande parte dos projetos, especialmente onde disponibilidade e determinismo são mandatórios. Nesse contexto, a robustez de uma rede PROFINET não depende apenas de projeto e comissionamento, ela depende de evidência contínua de saúde operacional.</p>
<p>Na prática, falhas raramente surgem sem sinais prévios. Antes do alarme de comunicação, aparecem tendências mensuráveis, como crescimento de jitter, aumento de netload, ocorrências de cycle fault, overtakes e, por fim, dropped no tráfego cíclico RT. O problema comercial por trás disso é direto: quando a planta reage apenas no evento, o MTTR cresce, o risco de paradas não programadas aumenta e o custo de intervenção se torna maior do que o custo de prevenção.</p>
<p>Este artigo apresenta uma abordagem completa de monitoramento, combinando captura passiva, via sniffer com TAP, e diagnósticos ativos, via leitura de estatísticas, topologia e saúde de portas e dispositivos, por exemplo via SNMP. Ao final, descreve uma aplicação típica com o <strong>TS Monitor PROFINET SNIFFER</strong>, que consolida monitoramento passivo e ativo e suporta <strong>PROFINET S1 e S2 em um único hardware</strong>, ponto relevante para arquiteturas redundantes e plantas de alta disponibilidade.</p>
<p><strong>Glossário prático: métricas que serão abordadas.<br />
</strong>Antes de entrar nos detalhes, seguem os termos que serão usados ao longo do texto:<br />
&#8211; <strong>IO Cycle:</strong> tempo de atualização cíclica por IO Device (base do desempenho do controle).<br />
&#8211; <strong>Jitter:</strong> variação do tempo de chegada dos telegramas em relação ao ciclo nominal; principal indicador de tendência.<br />
&#8211; <strong>Dropped:</strong> perda efetiva no ciclo cíclico de I/O (impacto direto no controle).<br />
&#8211; <strong>Overtake:</strong> telegramas fora de ordem (sinal de anomalia; exige investigação dirigida).<br />
&#8211; <strong>Cycle fault:</strong> pacotes atrasados acima de um limite (por exemplo, jitter &gt; 100% do ciclo).<br />
&#8211; <strong>Netload:</strong> carga de rede e sua composição (controle vs tráfego externo).</p>
<p><strong>1 &#8211; O que realmente degrada uma rede PROFINET<br />
</strong>Em campo, é comum atribuir falhas de rede a explicações genéricas (“partida de motor”, “interferência”, “mudança de carga”). Para a rede PROFINET, essas hipóteses só fazem sentido quando são <strong>comprovadas por evidências</strong> de camada física e de switch: <strong>erros de porta</strong>, <strong>eventos de link</strong>, <strong>descartes</strong>, <strong>crescimento de jitter</strong> e <strong>perdas no tráfego cíclico</strong>. Sem medição, o diagnóstico vira tentativa e erro.</p>
<p>A degradação costuma aparecer em três frentes:<br />
<strong>1.1 Degradação por camada física e montagem<br />
</strong>A origem mais frequente está em detalhes “simples”, porém críticos: <strong>conectores mal montados</strong>, blindagem inadequada, raio de curvatura excedido, danos mecânicos, umidade/ingresso de água ou componentes fora de especificação. O efeito típico é gradual e observável:<br />
&#8211; Aumento de <strong>erros/descartes</strong> em portas;<br />
&#8211; Perdas <strong>intermitentes</strong>;}<br />
&#8211; <strong>Jitter</strong> crescente (instabilidade do ciclo);<br />
&#8211; <strong>Link flaps</strong> (oscilações de link).</p>
<p>Em redes PROFINET, pequenos desvios na camada física tendem a se traduzir primeiro em instabilidade temporal (jitter) e, em seguida, em perdas efetivas de pacotes.</p>
<p><strong>1.2 Degradação por tráfego e filas de switch<br />
</strong>PROFINET cíclico (RT) depende de previsibilidade. Quando a rede opera perto do limite, ou quando surgem microcongestionamentos, aumenta a <strong>variação de latência</strong> — observada como <strong>jitter</strong>. Se o problema continuar, o próximo degrau é o <strong>packet dropping </strong>nos buffers dos switches.</p>
<p>Aqui está o ponto de valor do monitoramento: <strong>tendência de jitter/netload </strong>permite avaliação de risco e <strong>risco </strong>e planejamento de <strong>ação</strong> antes do evento afetar o processo.</p>
<p><strong>1.3 Degradação por configuração, topologia e manutenção<br />
</strong>A terceira frente é menos “visível” e costuma consumir mais tempo de equipe: mudanças de topologia, comportamento inesperado de redundância (MRP/MRPD), inconsistências de engenharia, velocidade/duplex, anomalias em broadcast/multicast (ARP/DCP), entre outras. Nesse conjunto, o <strong>monitoramento ativo</strong> é decisivo: ele aponta <strong>onde</strong> o problema está (porta/dispositivo/topologia), enquanto o passivo mostra <strong>como</strong> isso se manifesta nos pacotes e <strong>quem</strong> está sendo impactado.</p>
<p><strong>2 &#8211; Detectar tendência é melhor do que “pegar a falha”<br />
</strong>O erro estratégico em manutenção de redes industriais é esperar um evento “catastrófico” para agir. Em muitos casos, ocorre a falha, busca o analisador e vai para campo realizar análise de falha. O caminho tecnicamente consistente é <strong>monitorar tendência</strong> e tratar degradação como fenômeno progressivo. Uma sequência típica em incidentes reais é:<br />
&#8211; <strong>Netload</strong> sobe ao longo de semanas (novos nós/serviços, tráfego indevido, mudanças de engenharia);<br />
&#8211; <strong>Jitter</strong> cresce (primeiro sintoma mensurável);<br />
&#8211; Surgem <strong>cycle faults</strong> e <strong>overtakes</strong> em condições específicas;<br />
&#8211; Aparece <strong>dropped</strong> e, finalmente, perda de conexão/alarme de comunicação.<br />
Ou seja: quando “a rede cai”, normalmente ela já estava “avisando” — desde que alguém estivesse medindo.</p>
<p><strong>3 &#8211; Monitoramento completo: passivo + ativo<br />
</strong><strong>3.1 Monitoramento passivo — por que TAP é a escolha robusta<br />
</strong>Monitoramento passivo é observar fluxos <strong>sem gerar tráfego adicional, </strong>sem alterar o comportamento da rede e o melhor, sem depender da resposta de dispositivos sobrecarregados. Há duas abordagens comuns:<br />
<strong>a) Espelhamento de porta (port mirroring / SPAN)<br />
</strong>É prático e útil, especialmente para troubleshooting. Porém, tem limitações estruturais que o tornam frágil como “sensor” permanente:<br />
&#8211; A porta espelho tem limite de taxa: <strong>TX+RX</strong> da porta monitorada pode exceder a capacidade do espelho → <strong>perda da cópia e até falha no switch</strong>;<br />
&#8211; Switches podem ter <strong>rate-limit</strong> ou descartar tráfego espelhado em picos;<br />
&#8211; Dependendo do equipamento, pode haver <strong>variação significativa de temporização</strong> na cópia, reduzindo confiabilidade para análises finas (por exemplo, jitter).<br />
Por isso, espelhamento é indicado para <strong>testes pontuais</strong>, não como base de monitoramento contínuo quando se busca precisão e cobertura total.</p>
<p><strong>b) TAP (Test Access Point)<br />
</strong>O TAP, inserido no link, entrega uma cópia <strong>fidedigna </strong>do tráfego e tipicamente com robustez superior para observação contínua:<br />
&#8211; Melhor confiabilidade para captura permanente;<br />
&#8211; Visibilidade consistente de fluxos críticos de controle;<br />
&#8211; Base adequada para auditoria técnica e correlação temporal (tendência/ocorrência);<br />
&#8211; Opções a prova de falha.</p>
<p>É nesse desenho que o <strong>TS Monitor PROFINET SNIFFER</strong> se encaixa: ele captura e interpreta pacotes de controle de forma <strong>passiva</strong> (sniffer/TAP) e calcula as métricas como <strong>jitter, dropped, overtake e netload</strong>.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-12781" src="https://www.profibus.org.br/wp-content/uploads/2026/03/IMAGEM-1.png" alt="" width="543" height="538" srcset="https://www.profibus.org.br/wp-content/uploads/2026/03/IMAGEM-1.png 1862w, https://www.profibus.org.br/wp-content/uploads/2026/03/IMAGEM-1-300x297.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/03/IMAGEM-1-1024x1015.png 1024w, https://www.profibus.org.br/wp-content/uploads/2026/03/IMAGEM-1-150x150.png 150w, https://www.profibus.org.br/wp-content/uploads/2026/03/IMAGEM-1-768x761.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/03/IMAGEM-1-1536x1522.png 1536w, https://www.profibus.org.br/wp-content/uploads/2026/03/IMAGEM-1-50x50.png 50w, https://www.profibus.org.br/wp-content/uploads/2026/03/IMAGEM-1-555x550.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/03/IMAGEM-1-1110x1100.png 1110w, https://www.profibus.org.br/wp-content/uploads/2026/03/IMAGEM-1-600x595.png 600w, https://www.profibus.org.br/wp-content/uploads/2026/03/IMAGEM-1-1200x1189.png 1200w" sizes="(max-width: 543px) 100vw, 543px" /></p>
<p><strong>3.2 Monitoramento ativo — o que o passivo não substitui<br />
</strong>Monitoramento ativo é consultar componentes (switches e dispositivos) para extrair diagnósticos, estado e contadores. Ele é indispensável para reduzir MTTR porque aponta <strong>onde</strong> investigar primeiro, por exemplo:<br />
&#8211; Portas com <strong>erros/descartes</strong> e mudanças de estado;<br />
&#8211; Consistência de topologia (vizinhança) e eventos de rede;<br />
&#8211; Saúde de protocolos de redundância (por exemplo, estado de anel);<br />
&#8211; Crescimento de contadores “silenciosos” (a rede ainda comunica, mas já está degradando).<br />
Além disso, indicadores quantitativos como <strong>pacotes perdidos</strong> obtidos via <strong>SNMP</strong> entregam evidência rastreável por porta — ideal para correlação objetiva com jitter, netload e eventos.</p>
<p><strong>4 &#8211; </strong><strong>Indicadores que realmente “enxergam” degradação<br />
</strong><strong>4.1 Netload<br />
</strong>Netload é o “termômetro” da ocupação da rede. Aumentos sustentados ou picos recorrentes indicam risco de congestionamento. O ideal é separar <strong>PNIO vs. não-PNIO</strong> e enxergar <strong>IN/OUT</strong>, porque isso mostra se a pressão vem do tráfego de controle ou de tráfego externo (TI, serviços diversos, varreduras, etc.).</p>
<p><strong>4.2 Perda de pacotes (via SNMP)<br />
</strong>Em redes PROFINET, <em>perda de pacotes</em> deve ser tratado como <strong>métrica quantitativa</strong>, obtida preferencialmente por <strong>contadores de porta lidos via SNMP</strong> em switches gerenciáveis. O valor mais útil é o <strong>incremento</strong>, pois permite:<br />
&#8211; Medir severidade;<br />
&#8211; Correlacionar com horários de instabilidade e intervenções;<br />
&#8211; Comparar segmentos e portas para localizar o foco.<br />
Na prática, a perda de pacotes detectada por SNMP representa perdas/descartes no nível Ethernet (por exemplo, quadros com erro e descartes por fila), conforme o fabricante expõe os contadores. Por isso, o ganho está em padronizar <strong>baseline</strong> e <strong>regras de alarme</strong> — e usar o indicador como evidência para planejamento de ações.</p>
<p><strong>4.3 Dropped (no ciclo RT)<br />
</strong>Em PROFINET cíclico, <strong>dropped</strong> é o indicador mais “duro”: significa que um pacote <strong>não chegou</strong>. Dropped tem ligação direta com desempenho do controle e deve disparar ação imediata (mitigar causa, reduzir tráfego indevido, corrigir infraestrutura, isolar origem).</p>
<p><strong>4.4 Jitter<br />
</strong>Jitter é a variação do tempo real entre telegramas consecutivos em relação ao ciclo configurado. É o melhor indicador de tendência porque cresce quando:<br />
&#8211; A rede se aproxima do limite (filas variam);<br />
&#8211; Há microcongestionamentos;<br />
&#8211; Surgem instabilidades físicas e de switching.<br />
Interpretação prática:<br />
&#8211; <strong>Netload alto + Jitter alto</strong> → risco de congestionamento e degradação progressiva.<br />
&#8211; <strong>Jitter alto sem Netload alto</strong> → investigar instabilidade física, priorização/filas, topologia e portas degradadas.<br />
&#8211; <strong>Dropped após jitter</strong> → rede entrou em regime de falha (ação imediata).</p>
<p><strong>4.5 Overtake<br />
</strong>&#8211; <strong>Overtake</strong> indica pacotes fora de ordem. Em redes industriais, é um gatilho útil para investigação dirigida (fenômenos de fila/caminho/condições anormais).</p>
<p><strong>4.6 Cycle fault<br />
</strong>&#8211; <strong>Cycle fault</strong> classifica pacotes atrasados acima de um limite (por exemplo, jitter &gt; 100% do ciclo) e funciona como ponte entre tendência (jitter) e falha (dropped).</p>
<p><strong>5 &#8211; Infraestrutura: por que cabeamento pronto, injetado e certificado reduz risco<br />
</strong>A camada física é onde mais se “economiza errado”. Cabos montados em campo exigem ferramental, treinamento e controle de qualidade. Em contraste, cabos <strong>pré-montados/injetados</strong> e <strong>certificados de fábrica</strong> reduzem:<br />
&#8211; Erros de montagem de conector;<br />
&#8211; Problemas de blindagem e continuidade;<br />
&#8211; Variabilidade por instalador;<br />
&#8211; Retrabalho e falhas intermitentes difíceis de reproduzir.<br />
Em PROFINET, isso tem impacto direto porque instabilidades pequenas viram <strong>jitter</strong> e, depois, <strong>dropped</strong> — e o custo do downtime tende a superar o custo marginal de padronização.<br />
Obs: switches fazem parte importante e, neste contexto, switches PROFINET com diagnóstico, interfaces Gigabit e gerenciáveis podem ser a diferença entre o sucesso e o fracasso no diagnóstico e robustez.</p>
<p><strong>6 &#8211; </strong><strong>Redundância PROFINET S2: por que monitorar fica mais complexo<br />
</strong>Em arquiteturas com <strong>Redudância de Sistema S2</strong>, o dispositivo mantém relação ativa com um controlador e relação de backup em standby, habilitando troca quase sem interrupção quando há falha no IO Controller ou do caminho/controlador ativo. Isso eleva disponibilidade, mas torna o diagnóstico mais sofisticado: é necessário enxergar tráfego, eventos e tendências associados aos dois caminhos e às transições.</p>
<p>O <strong>TS Monitor PROFINET SNIFFER</strong> atende <strong>PROFINET S2 em um único hardware</strong>, evitando múltiplas ferramentas e permitindo visibilidade contínua — ponto relevante em plantas que requerem alta disponibilidade.</p>
<p><strong>7 &#8211; </strong><strong>Aplicação típica com o TS Monitor PROFINET SNIFFER<br />
</strong><strong>7.1 Objetivo<br />
</strong>Implementar monitoramento contínuo para:<br />
&#8211; Criar <strong>baseline</strong> do comportamento normal (por segmento/célula/controlador);<br />
&#8211; Detectar <strong>tendência</strong> antes de falha (jitter/netload/pacotes perdidos);<br />
&#8211; Reduzir <strong>mttr</strong> quando a falha ocorre (evidência objetiva e localização mais rápida);<br />
&#8211; Produzir evidência técnica (relatórios/eventos) para gestão e auditoria.</p>
<p><strong>7.2 Arquitetura recomendada (passivo + ativo)<br />
</strong>Inserir o TS Monitor PROFINET SNIFFER no mesmo painel do IO Controller e conectar os cabos PROFINET passando pelo TAP do equipamento. Em outro ponto conectar o cabo para a comunicação ativa do sistema de monitoramento. A figura abaixo mostra a conexão em sistema S2.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-12782" src="https://www.profibus.org.br/wp-content/uploads/2026/03/IMAGEM-2-scaled.png" alt="" width="772" height="379" srcset="https://www.profibus.org.br/wp-content/uploads/2026/03/IMAGEM-2-scaled.png 2560w, https://www.profibus.org.br/wp-content/uploads/2026/03/IMAGEM-2-300x147.png 300w, https://www.profibus.org.br/wp-content/uploads/2026/03/IMAGEM-2-1024x503.png 1024w, https://www.profibus.org.br/wp-content/uploads/2026/03/IMAGEM-2-768x377.png 768w, https://www.profibus.org.br/wp-content/uploads/2026/03/IMAGEM-2-1536x754.png 1536w, https://www.profibus.org.br/wp-content/uploads/2026/03/IMAGEM-2-2048x1005.png 2048w, https://www.profibus.org.br/wp-content/uploads/2026/03/IMAGEM-2-555x272.png 555w, https://www.profibus.org.br/wp-content/uploads/2026/03/IMAGEM-2-1110x545.png 1110w, https://www.profibus.org.br/wp-content/uploads/2026/03/IMAGEM-2-600x294.png 600w, https://www.profibus.org.br/wp-content/uploads/2026/03/IMAGEM-2-1200x589.png 1200w" sizes="(max-width: 772px) 100vw, 772px" /></p>
<p>Pontos importantes:<br />
&#8211; Monitor ao ponto de observação passiva para <strong>captura integral de pacotes de controle</strong>.<br />
&#8211; Habilitar diagnósticos ativos em switches e dispositivos (quando aplicável) para coletar contadores, topologia e status.</p>
<p><strong>7.3 O que o TS Monitor entrega “a mais” na prática<br />
</strong>O ganho não é “ver pacotes”: é reduzir o ciclo <strong>suspeita → tentativa → erro</strong> e migrar para um modelo orientado a evidência:<br />
&#8211; <strong>Preditivo:</strong> baseline + tendência (jitter/netload) antes do evento.<br />
&#8211; <strong>Quantitativo:</strong> pacotes perdidos via SNMP com valor rastreável por janela.<br />
&#8211; <strong>Direto no controle:</strong> dropped/cycle fault ligados ao PN-IO (impacto real).<br />
&#8211; <strong>Completo:</strong> passivo (pacotes) + ativo (topologia/estatísticas/estado).<br />
&#8211; <strong>Alta disponibilidade:</strong> suporte a <strong>S2 em um único equipamento</strong>, simplificando o monitoramento em redes redundantes.</p>
<p><strong>Conclusão<br />
</strong>Monitorar PROFINET de forma consistente significa abandonar diagnóstico puramente reativo e adotar um modelo técnico e mensurável: medir tendência, jitter e netload, quantificar perdas por porta via contadores, detectar perda efetiva no ciclo RT, dropped, correlacionar com saúde de rede em diagnósticos ativos e garantir visibilidade de fluxos por captura passiva com TAP.</p>
<p>O <strong>TS Monitor PROFINET SNIFFER</strong> operacionaliza esse modelo ao consolidar leitura passiva de telegramas de controle e diagnósticos ativos, com suporte a <strong>PROFINET S2 em um único hardware</strong>, diferencial para plantas que exigem previsibilidade e alta disponibilidade.</p>
<p>Essa novidade estará disponível a partir de <strong>junho de 2026</strong>. Agende uma demonstração online para validar, com dados da sua própria planta, como baseline de netload e jitter pode antecipar degradação, reduzir MTTR e sustentar decisões de correção com evidência.</p>
<p><strong>Telefone:</strong> +55 (16) 3419 1577<br />
<strong>E-mail:</strong> vendas@toledoesouza.com<strong> </strong></p>
<p>&nbsp;</p>
<p><em><strong>Referências:</strong></em></p>
<ol>
<li><strong>HMS NETWORKS.</strong> <em>Industrial Network Study</em>. Halmstad: HMS Networks, 2023.</li>
<li><strong>PROFIBUS NUTZERORGANISATION E.V. (PNO).</strong> <em>PROFINET Commissioning Guideline</em>. Karlsruhe: PNO, 2022. Order No. 8.082, Version 1.53.</li>
<li><strong>PROFIBUS NUTZERORGANISATION E.V. (PNO).</strong> <em>PROFINET Design Guideline</em>. Karlsruhe: PNO, 2022. Order No. 8.062, Version 1.53.</li>
<li><strong>PROFIBUS NUTZERORGANISATION E.V. (PNO).</strong> <em>PROFINET Assembling Guideline</em>. Karlsruhe: PNO, 2022. Order No. 8.072, Version 2.12.</li>
<li><strong>PROFIBUS NUTZERORGANISATION E.V. (PNO).</strong> <em>PROFINET Planning Redundancy</em>. Karlsruhe: PNO, 2023. Order No. 8.132, Version 1.00.</li>
<li><strong>CISCO SYSTEMS.</strong> <em>SPAN/RSPAN/ERSPAN Configuration Guide</em>. San Jose: Cisco Systems, 2012.</li>
<li><strong>TS REDES INDUSTRIAIS.</strong> <em>Guia do usuário TS Monitor PROFINET PRO SN</em>. Versão 1.0.1. [S.l.]: TS Redes Industriais, s.d.</li>
</ol>
<p>&nbsp;</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.profibus.org.br/noticia/monitoramento-completo-de-redes-profinet/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">12793</post-id>	</item>
		<item>
		<title>O que o Ethernet-APL mudou ou mudará quando falamos de medidores de vazão?</title>
		<link>https://www.profibus.org.br/noticia/o-que-o-ethernet-apl-mudou-ou-mudara-quando-estamos-falando-de-medidores-de-vazao/</link>
					<comments>https://www.profibus.org.br/noticia/o-que-o-ethernet-apl-mudou-ou-mudara-quando-estamos-falando-de-medidores-de-vazao/#respond</comments>
		
		<dc:creator><![CDATA[Marketing]]></dc:creator>
		<pubDate>Thu, 05 Feb 2026 15:28:47 +0000</pubDate>
				<category><![CDATA[Artigo técnico]]></category>
		<guid isPermaLink="false">https://www.profibus.org.br/?p=12731</guid>

					<description><![CDATA[ENDRESS+HAUSER O impacto do Ethernet-APL nos medidores de vazão: a evolução que está transformando o campo A chegada do Ethernet-APL (Advanced Physical Layer) representa uma das maiores revoluções tecnológicas para o nível de campo na automação de processos. Para os medidores de vazão, sua adoção redefine padrões de conectividade, desempenho, diagnóstico e eficiência operacional. Mais [&#8230;]]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><a href="https://www.br.endress.com/pt" target="_blank" rel="noopener"><strong>ENDRESS+HAUSER</strong></a></p>
<p style="text-align: center;"><strong>O impacto do Ethernet-APL nos medidores de vazão: a evolução que está transformando o campo</strong></p>
<p>A chegada do <strong>Ethernet-APL (Advanced Physical Layer)</strong> representa uma das maiores revoluções tecnológicas para o nível de campo na automação de processos. Para os <strong>medidores de vazão</strong>, sua adoção redefine padrões de conectividade, desempenho, diagnóstico e eficiência operacional.</p>
<p>Mais do que uma simples camada física, o Ethernet-APL abre caminho para plantas <strong>totalmente digitais</strong>, com dados mais acessíveis, instalação simplificada e integração direta com sistemas de automação modernos — tudo isso mantendo compatibilidade com áreas classificadas.</p>
<p><strong>Alguns tópicos que trazem essa inovação:</strong><br />
<strong>1- Conectividade total: dados ricos, rápidos e sem conversões<br />
</strong>Tradicionalmente, os medidores de vazão dependiam de protocolos como 4-20 mA + HART ou fieldbus, que apresentam limitações como baixa velocidade, diagnósticos restritos e necessidade de conversão de sinal.</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-12718" src="https://www.profibus.org.br/wp-content/uploads/2026/02/imagem-2.jpg" alt="" width="763" height="334" srcset="https://www.profibus.org.br/wp-content/uploads/2026/02/imagem-2.jpg 1099w, https://www.profibus.org.br/wp-content/uploads/2026/02/imagem-2-300x131.jpg 300w, https://www.profibus.org.br/wp-content/uploads/2026/02/imagem-2-1024x448.jpg 1024w, https://www.profibus.org.br/wp-content/uploads/2026/02/imagem-2-768x336.jpg 768w, https://www.profibus.org.br/wp-content/uploads/2026/02/imagem-2-555x243.jpg 555w, https://www.profibus.org.br/wp-content/uploads/2026/02/imagem-2-600x263.jpg 600w" sizes="(max-width: 763px) 100vw, 763px" /></p>
<p>Com o Ethernet APL, os dados passam a ser <strong>100% digitais</strong>, com comunicação full-duplex em <strong>10 Mbit/s</strong>, permitindo:<br />
&#8211; Aquisição de dados em alta velocidade.<br />
&#8211; Comunicação contínua e rica para diagnósticos avançados.<br />
&#8211; Acesso remoto direto ao servidor web do instrumento.<br />
&#8211; Eliminação de gateways e conversões de protocolo.</p>
<p>Essas capacidades são destacadas em materiais da <strong>Endress+Hauser</strong> que mostram o acesso facilitado ao <em>webserver</em>, parametrização remota e download de arquivos de dispositivo diretamente pelo IP do instrumento.</p>
<p><strong>2- Instalação mais simples: dois fios, energia e dados juntos<br />
</strong>Uma das grandes barreiras da Ethernet tradicional em campo sempre foi o cabeamento.<br />
O Ethernet-APL resolve isso ao permitir <strong>energia e dados no mesmo par de fios</strong>, mantendo:<br />
&#8211; Comprimentos de cabo de até <strong>1.000 metros<br />
</strong>&#8211; Instalação segura em <strong>áreas classificadas (Ex i)<br />
</strong>&#8211; Insensibilidade à polaridade<br />
&#8211; Compatibilidade com topologias flexíveis e redundantes</p>
<p>Apresentações técnicas internas reforçam que essa simplificação reduz riscos, tempo de engenharia e complexidade, além de possibilitar expansões mais rápidas.</p>
<p><strong>3- Velocidade que muda o jogo: downloads 98% mais rápidos<br />
</strong>Um dado impressionante comprovado em testes mostra que um download que antes levava cerca de <strong>8 minutos</strong> em tecnologia analógica ou 3 minutos no Fieldbus, agora é concluído em apenas <strong>10 segundos</strong> com o Ethernet-APL. Ao escalar para uma planta com <strong>200 dispositivos</strong>, isso significa:</p>
<p><img loading="lazy" decoding="async" class="aligncenter wp-image-12717" src="https://www.profibus.org.br/wp-content/uploads/2026/02/imagem-01.jpg" alt="" width="768" height="337" srcset="https://www.profibus.org.br/wp-content/uploads/2026/02/imagem-01.jpg 1120w, https://www.profibus.org.br/wp-content/uploads/2026/02/imagem-01-300x132.jpg 300w, https://www.profibus.org.br/wp-content/uploads/2026/02/imagem-01-1024x450.jpg 1024w, https://www.profibus.org.br/wp-content/uploads/2026/02/imagem-01-768x337.jpg 768w, https://www.profibus.org.br/wp-content/uploads/2026/02/imagem-01-555x244.jpg 555w, https://www.profibus.org.br/wp-content/uploads/2026/02/imagem-01-1110x488.jpg 1110w, https://www.profibus.org.br/wp-content/uploads/2026/02/imagem-01-600x264.jpg 600w" sizes="(max-width: 768px) 100vw, 768px" /></p>
<p>&#8211; HART: 26h40min<br />
&#8211; Fieldbus: 10h<br />
&#8211; Ethernet-APL: 33min</p>
<p>Uma economia de tempo que pode chegar a <strong>98%</strong>.</p>
<p>Essa velocidade muda o padrão para manutenção, comissionamento e atualização de firmware.</p>
<p><strong>4- Diagnósticos avançados: heartbeat e monitoramento contínuo<br />
</strong>Medidores de vazão equipados com Heartbeat Technology já eram referência em diagnósticos avançados, mas com Ethernet-APL o salto é ainda maior:<br />
&#8211; Integração completa de diagnósticos em tempo real<br />
&#8211; Verificação e monitoramento contínuos<br />
&#8211; Possibilidade de automação da avaliação diretamente no DCS<br />
&#8211; Detecção mais rápida de anomalias, como <strong>incrustação em medidores Coriolis.</strong></p>
<p>Esse uso já é demonstrado em slides internos que mostram como o APL permite detecções mais sensíveis e automatizadas no monitoramento de vibração e amortecimento.</p>
<p><strong>5- Plantas mais disponíveis e na era da digitalização<br />
</strong>Com Ethernet-APL, os medidores de vazão deixam de ser apenas “pontos de medição” para se tornarem <strong>fontes inteligentes contínuas de informação</strong>, integradas a aplicações:<br />
&#8211; IIoT<br />
&#8211; Indústria 4.0<br />
&#8211; Otimização contínua de processos<br />
&#8211; Estratégias preditivas de manutenção<br />
&#8211; Acesso remoto seguro e rápido</p>
<p>O conteúdo interno reforça que esta camada física avançada permite uma <strong>planta totalmente conectada</strong>, com dados centralizados e maior disponibilidade operacional.</p>
<p><strong>6- Prontidão de mercado: portfólio já amplamente disponível<br />
</strong>A tecnologia não é mais futuro: <strong>ela já está presente.</strong><br />
A Endress+Hauser, por exemplo, já disponibiliza medidores de vazão Promag, Promass e Prowirl com eletrônica 300/500 preparados para Ethernet-APL — inclusive <strong>com produção local no Brasil.</strong></p>
<p>Além disso:<br />
&#8211; Switches APL, sensores e infraestrutura já estão amplamente disponíveis.<br />
&#8211; Testes massivos com dezenas de dispositivos em múltiplos DCS já demonstraram robustez e maturidade da solução.</p>
<p><strong>7- O futuro: uma única tecnologia de rede para todo o nível de campo<br />
</strong>Se antes a instrumentação dependia de múltiplas tecnologias (HART, fieldbus, 4-20 mA), o Ethernet-APL inaugura uma nova era: <strong>uma única camada de rede para toda a automação de processos</strong>.</p>
<p>Essa evolução elimina barreiras entre TI e TO e simplifica todo o ciclo de vida da instrumentação — do projeto à operação.</p>
<p><strong>Conclusão<br />
</strong>O Ethernet-APL representa um divisor de águas para os medidores de vazão.<br />
Ele entrega velocidade, simplicidade, segurança e uma capacidade de diagnóstico e integração nunca vistas antes no nível de campo.</p>
<p>Não se trata apenas de “mais um padrão de comunicação”, mas sim de uma tecnologia que <strong>prepara as plantas para a digitalização real</strong>, reduz custos, melhora a confiabilidade e impulsiona a eficiência operacional.</p>
<p>O futuro dos medidores de vazão — e da instrumentação como um todo — é claramente <strong>Ethernet-APL</strong>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.profibus.org.br/noticia/o-que-o-ethernet-apl-mudou-ou-mudara-quando-estamos-falando-de-medidores-de-vazao/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">12731</post-id>	</item>
		<item>
		<title>O que é Smart Radio e como funciona?</title>
		<link>https://www.profibus.org.br/noticia/o-que-e-smart-radio-e-como-funciona/</link>
					<comments>https://www.profibus.org.br/noticia/o-que-e-smart-radio-e-como-funciona/#respond</comments>
		
		<dc:creator><![CDATA[Marketing]]></dc:creator>
		<pubDate>Sat, 05 Jul 2025 18:37:03 +0000</pubDate>
				<category><![CDATA[Artigo técnico]]></category>
		<guid isPermaLink="false">https://www.profibus.org.br/?p=12009</guid>

					<description><![CDATA[autoria: Thomas Schildknecht (*) tradução: Paolo Capecchi (*) Os sistemas de transmissão de dados wireless são essenciais para muitas aplicações industriais. O link de rádio deve ser estável e altamente disponível, a fim de evitar paradas indesejadas em máquinas e processos — e, ao mesmo tempo, seguro o suficiente para ser usado em aplicações de [&#8230;]]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"><img loading="lazy" decoding="async" class="aligncenter wp-image-12016 " src="https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-capa-1.png" alt="" width="560" height="351" srcset="https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-capa-1.png 944w, https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-capa-1-300x188.png 300w, https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-capa-1-768x482.png 768w, https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-capa-1-555x348.png 555w, https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-capa-1-600x376.png 600w" sizes="(max-width: 560px) 100vw, 560px" /></p>
<p style="text-align: right;"><em>autoria:<br />
</em><em>Thomas Schildknecht (<strong>*</strong>)<br />
</em></p>
<p style="text-align: right;"><em>tradução:<br />
</em><em>Paolo Capecchi (<strong>*</strong>)</em></p>
<p>Os sistemas de transmissão de dados wireless são essenciais para muitas aplicações industriais. O link de rádio deve ser estável e altamente disponível, a fim de evitar paradas indesejadas em máquinas e processos — e, ao mesmo tempo, seguro o suficiente para ser usado em aplicações de missão crítica, como sistemas de parada de emergência com protocolo PROFIsafe.</p>
<p>Este artigo descreve as tecnologias patenteadas que garantem uma comunicação de dados segura e sem falhas, além de explicar por que, hoje, já é possível substituir o cabo por um link de rádio com total segurança em suas aplicações.<strong> </strong></p>
<p><strong>Desafios<br />
</strong>Os ganhos econômicos e operacionais dessas aplicações dependem de um equilíbrio entre disponibilidade, confiabilidade e segurança na operação diária. Em aplicações com /*movimentação de cargas (como guindastes, pontes rolantes, shiploaders etc.), é necessário atender a normas de segurança rigorosas — um desafio não apenas para os sistemas de acionamento e controle, mas também para as redes de comunicação de dados wireless.</p>
<p>Embora seja impossível eliminar completamente as fontes de interferência em sistemas complexos de rádio, é possível impedir que essas perturbações afetem o controle e, consequentemente, a disponibilidade da planta. Duas medidas principais contribuem para isso:</p>
<ol>
<li>O projeto do link de rádio — especialmente a escolha da tecnologia wireless — deve considerar todas as influências ambientais da aplicação;</li>
<li>Os módulos de rádio devem ser inteligentes o suficiente para detectar, interpretar e neutralizar interferências a tempo, evitando impactos na comunicação entre o controlador e os dispositivos remotos. Esses módulos devem atuar como filtros inteligentes entre o controlador e os dispositivos conectados na outra extremidade do link.</li>
</ol>
<p>Essas funções são especialmente importantes em sistemas de intertravamento de segurança via rádio.</p>
<p>A tecnologia de conexão wireless segura para redes PROFIBUS DP foi desenvolvida pela Schildknecht AG há muitos anos e é totalmente compatível com o protocolo PROFIsafe. Presente em todos os rádios DATAEAGLE, essa tecnologia combina hardware específico e firmware proprietário, incluindo um bloco de função (Function Block – FB) patenteado pela Schildknecht.<strong> </strong></p>
<p><strong>Conexão via Cabo</strong><strong> </strong><strong><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-12018" src="https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-conexao-via-cabo.png" alt="" width="949" height="269" srcset="https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-conexao-via-cabo.png 949w, https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-conexao-via-cabo-300x85.png 300w, https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-conexao-via-cabo-768x218.png 768w, https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-conexao-via-cabo-555x157.png 555w, https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-conexao-via-cabo-600x170.png 600w" sizes="(max-width: 949px) 100vw, 949px" /></strong></p>
<p><strong>Princípio de funcionamento – conexão convencional<br />
</strong>Em máquinas e equipamentos, a comunicação entre CLP, sensores e atuadores se dá por redes padronizadas como PROFIBUS DP, PROFINET IO ou CAN. Nelas, pacotes de dados (telegramas) são trocados entre o CLP e os módulos de E/S — normalmente a cada milissegundo.<strong> </strong></p>
<p><strong>Quantos metros de cabo?<br />
</strong>Em geral, mais de um módulo de E/S está conectado ao CLP. E, em máquinas com partes móveis, os cabos estão sujeitos a desgaste mecânico intenso — podendo, em certos casos, inviabilizar o uso da solução cabeada.<strong> </strong></p>
<p><strong>Link de Rádio</strong><strong> </strong><strong><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-12019" src="https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-link-de-radio.png" alt="" width="953" height="301" srcset="https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-link-de-radio.png 953w, https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-link-de-radio-300x95.png 300w, https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-link-de-radio-768x243.png 768w, https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-link-de-radio-555x175.png 555w, https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-link-de-radio-600x190.png 600w" sizes="(max-width: 953px) 100vw, 953px" /></strong></p>
<p><strong>Princípio da transmissão de dados – tempo de resposta dentro da tolerância<br />
</strong>A comunicação via redes wireless pode ser feita com tecnologias como WLAN ou Bluetooth. O cabo é substituído por dois módulos de rádio. Para que a rede PROFIBUS DP funcione corretamente, o tempo de resposta predefinido (geralmente entre 16 ms e 128 ms) precisa ser respeitado.<strong> </strong></p>
<p><strong>Tempo de resposta acima da tolerância<br />
</strong>Se o tempo de resposta for excedido — por exemplo, devido a uma interferência eletromagnética, os pacotes serão perdidos e o CLP e os módulos de E/S entrarão em estado de erro de barramento, levando à parada do processo e a prejuízos operacionais.<strong> </strong></p>
<p><strong>Redes Wireless com rádios convencionais</strong><strong> </strong><strong><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-12020" src="https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-radios-convencionais.png" alt="" width="941" height="306" srcset="https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-radios-convencionais.png 941w, https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-radios-convencionais-300x98.png 300w, https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-radios-convencionais-768x250.png 768w, https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-radios-convencionais-555x180.png 555w, https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-radios-convencionais-600x195.png 600w" sizes="(max-width: 941px) 100vw, 941px" /></strong></p>
<p><strong>Sem pré-processamento inteligente<br />
</strong>Rádios convencionais transmitem os pacotes de dados sem analisar seu conteúdo. Com isso, todos os pacotes precisam ser enviados, o que pode facilmente sobrecarregar o link de rádio.<strong> </strong></p>
<p><strong>Perda ou atraso de pacotes<br />
</strong>Pacotes perdidos, incompletos ou atrasados — causados por interferências — provocam erros de barramento e a parada da máquina. O CLP continuará enviando novos pacotes a cada 16 a 128 ms, sobrecarregando ainda mais o sistema.<strong> </strong></p>
<p><strong>Redes Wireless com pré-processamento inteligente</strong><strong><img loading="lazy" decoding="async" class="aligncenter size-full wp-image-12021" src="https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-smart-radio.png" alt="" width="941" height="308" srcset="https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-smart-radio.png 941w, https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-smart-radio-300x98.png 300w, https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-smart-radio-768x251.png 768w, https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-smart-radio-555x182.png 555w, https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-smart-radio-600x196.png 600w" sizes="(max-width: 941px) 100vw, 941px" /></strong></p>
<p><strong>Smart Radio – transmissão inteligente de dados<br />
</strong>O sistema Smart Radio DATAEAGLE faz o pré-processamento dos dados diretamente no módulo de rádio. Algoritmos patenteados verificam conteúdo, timestamp e redundância dos pacotes, analisando os dados em blocos menores. Quando necessário, os pacotes são armazenados temporariamente. A porta PROFIBUS DP e o módulo de RF operam de forma totalmente independente, garantindo comunicação sem falhas — com um novo pacote podendo ser processado a cada milissegundo.<strong> </strong></p>
<p><strong>Processamento de dados confiável<br />
</strong>O pré-processamento assegura disponibilidade contínua da máquina. Com a tecnologia Smart Radio, telegramas incompletos são reconstruídos, pacotes atrasados são substituídos e a comunicação em tempo real é superior à dos sistemas convencionais — mesmo sob interferências eletromagnéticas.<strong> </strong></p>
<p><strong>Smart Wireless</strong><strong> </strong><strong><img loading="lazy" decoding="async" class="aligncenter wp-image-12017" src="https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-capa.png" alt="" width="620" height="389" srcset="https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-capa.png 944w, https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-capa-300x188.png 300w, https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-capa-768x482.png 768w, https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-capa-555x348.png 555w, https://www.profibus.org.br/wp-content/uploads/2025/07/post-profibus-dp-wireless-capa-600x376.png 600w" sizes="(max-width: 620px) 100vw, 620px" /></strong></p>
<p><strong>Benefícios e vantagens</strong><strong> </strong></p>
<p><strong>Otimização do tráfego de dados<br />
</strong>O pré-processamento reduz o uso do link de rádio e desacopla a porta PROFIBUS DP da rede wireless. Os telegramas são armazenados temporariamente e analisados por participante, o que permite operar com taxas de até 1,5 Mbps sem alterar a configuração do mestre PROFIBUS.<strong> </strong></p>
<p><strong>Filtro de tempo configurável<br />
</strong>Um filtro de tempo ajustável permite manter a comunicação estável mesmo durante breves interferências. Isso evita erros de barramento e paradas do sistema. Em caso de falha prolongada do link, o erro é sinalizado ao CLP, que ativa os procedimentos de segurança. O tempo do filtro pode ser ajustado entre 20 ms e 20 s.<strong> </strong></p>
<p><strong>Firewall inteligente<br />
</strong>O mestre PROFIBUS envia dados cíclicos com tempo de ciclo inferior a 1 ms a 1,5 Mbps — mesmo que os dados não mudem. O Smart Radio reconhece telegramas repetidos e os filtra, reduzindo o tráfego no link de rádio. Apenas telegramas com dados efetivamente alterados são transmitidos. O tempo de atualização após o link é de cerca de 20 ms.</p>
<p>&nbsp;</p>
<p><em><strong>Autor:<br />
</strong>(<strong>*</strong>) Thomas Schildknecht, CEO da Schildknecht AG.<strong> </strong></em></p>
<p><em><strong>Tradução:<br />
</strong>(<strong>*</strong>) Paolo Capecchi, diretor da Westcon Instrumentação Industrial Ltda.</em></p>
<p>&nbsp;</p>
]]></content:encoded>
					